Fire Truck Passage6.0.1 The road within the street should be considered with pass of fire truck, it's better the distance of road central line is not more than 160.0m. When the length of biiilduig along the stieet is more than 150.0m or the total length is more than 220,0m, then tliefire tiiick passage passiug thiough the builduigs should be anauged. When it's really difficult to realize, then the circled fire truck passage should be arranged.6-0-2 For the buUduigs with closed courtyard or open yard, when he length of its shonside is more than 24-Om, it's better the fire truck passage is arranged to enter tlie courtyard or open yard.6.03 If the builduigs with closed couilyaid and open yard is built along the street.then the pedestrian passage counectmg the street and the couiiyard should be arranged(the staircase could be used), but ifs better the distance is not more than 80.0m.6.0.4 On both sides of fire tnick passage passiug lluougli the builduigs or entering the courtyard, the facilities affecting the fiie tiiick pass or people evacuation should notbe anaiiged-6.0.5 For public buildings such as the stadium with more tliau 3,000 seats, conferencehall with seats more tlian 2,000 and exlubition hall with site area more than 3,0(X)sqm,tlie circled fire truck passage is better to be anaiiged.6.0.6 Fire truck passage should be arranged ui the factory and storage area.For the Class-A. Class-B and Class-C factoiy with site aiea more than 3.000sqmor Class-B & Class-C storage with site area more tliau l,500sqm, the circled fiie truck passage should be anaxiged, if it's really difficult to realize, then the fire truck passage should be arranged aloug two long sides of buildings.6-0-7 For the combustible material stock dump, LGP storage area, liquid storage tankarea on Class-A, Class-B & Class-C and combustible gas storage tank area, the firetiiick passage should be aiiaiiged. Aud the airaugement of fire truck passage should satisfy the following regulations:L If the storage volume is more than the stock dump, and storage tank area mentionedui Sheet 6-0.7, the ciicled fire truck passage is better to be anauged,2.For the combustible material stock dump with site aiea more than 30,000sqiih thefire truck passage in the middle should be arranged to connect with circled fire truck passage, and the distance between fire truck passages is better not more than 150-Oni- For LGP storage area, liquid storage area on ClassA Class-B & Class-C, andcombustible gas storage area, the circled fire tnick passage within these areas is better to be aiiauged with coiuiectmg file tinck passage.3.The muumiim distance between tlie fire truck passage and material stock dumpshould be not less than 5.0m4.The comiectmg part between the fire truck passage ui the middle aud circled firetiiick passage should satisfy the requkeuients for turning radius of fire truck.6.0.8 The natural water souice aud fire water tauk supplying water to the fiie truck should be arranged with fire truck passage.6-0-9 The net width and cleai heiglit of fiie tnick passage should be not less than 4.0m. The slope of empty space for parkuig the fire tnick is better not more than 3%. Thespace between the file truck passage aud factory (storage) aud civil buildings shouldnot be arranged with barriers that may affect the operation of fire truck.6-0-10 The ciicled fke truck passage should have at least two positious coiiuectiiigwith other truck passage. The end-type fire truck passage should be arranged withtunuiig passage oi turning field, aud the area of tuiniug field should be not less tliau12-Oni * 12.0111; if it's used for large fire truck, then the area is better not less thanThe file truck passage, rescue operation place, pipmg and blind ditch below andothers should have enough bearing capacity for the file trucks.The fire truck passage could use tlie traffic road, but the pass and paiking for filetruck should be satisfied.6.0.11 It's better the fke tnick passage is not ui level cross with railway tnuik line. If K's really necessary to be iii level cross, tlieu the back-up passage should be arranged. and the distance between two passages should be not less tlian the length of one train.5 Civil Building5.1.1 Fue resistance of civil building is classified as Level I IL III & IV. Unless othenvise regulated, the combustion perfbiuiance aud fire resistance of components iu buildings on different levels of fire resistance should be not lower tlian the regulations m Sheet 5.LI.Sheet 5-1-1 Combustion perfbrmauce and fire resistance of building components (h)Note: 1. Unless othenvise regulated, for the buildings with wood pUlai for bearing and non-combustible component as wall, its fire resistance should be deteniiuied asLeveMV, 2. When the ceiling of buildings with fire resistance on Level II is noii-combustible component, its fire resistance is not luiuted.3- In the buildmgs on Level 11 fire resistance, fbi the separation wall of room with area not more than lOOsqm, if it's really difficult to follow the regulations in this form.then the uou-combustible components with fiie resistance not lower than 0.3n could be used;4. For the separation wall ou both sides of emergency passage in buildings ou Level I & II fire resistance, if it's really difficult to follow the regulations ui this form, then the 0.7h non-combustible component could be used.54.2 Ill buildings with Level II fire resistance, when the room separation wall uses tlie difficult-combustible component, its fire resistance should be uicreased by 0・25h・5.13 For accessible flat roof with Level I & II file resistance, the file resistance of its roof plate should be not lower than 1.5011 aud LOOli respectively.54-4 The roof plate of buildmgs with Level I & II fue resistance should use uou*combustible components, but its roof water-proof layer aud heat msulatiou layer could use combustible component.•5-1-5 When the floor slab of residential buildmg with Level I & II file resistance is prestiessed reinforced concrete, then the fire resistance of the slab should be not lower than 0.7511.5・1・6 The ceilmg of builduigs with Level III fire resistance below should use uou-combustible component oi difficult-combustible component with fire resistance not lower than 0.25h;1.HospKal, sanatorium, pnmaiy and nuddle school® Buildings for the aged, cluld-caie ceutei; childreiVsroom of kuiderganen, children's anuisement hall and other cluldren^s activity place,2.The eutiauce hall aud passage iii builduigs with tluee or more floors.5丄7 The file resistance, maximum allowable floors aud the maxuiium allowable binlduig aiea in fire zone of civil buildings should satisfy the regulations lu Sheet 54.7.Sheet 5.1.7 Fire resistance, maximum allowable floors and the niaxuiwin allowable building area。

相关主题