当前位置:文档之家› 三菱变频器A540与A740新旧对比说明书

三菱变频器A540与A740新旧对比说明书

1.尺寸FREQROL-A540-CH系列更换为FREQROL-A740-CHT系列的场合、其安装尺寸比较和外形对照如下:【变频器单体的场合】原有变频器更换后的变频器尺寸对比和安装互换性FR-A540-0.4K-CH FR-A740-0.4K-CHTFR-A540-0.75K-CH FR-A740-0.75K-CHTFR-A540-1.5K-CH FR-A740-1.5K-CHTFR-A540-2.2K-CH FR-A740-2.2K-CHTFR-A540-3.7K-CH FR-A740-3.7K-CHTFR-A540-5.5K-CH FR-A740-5.5K-CHTFR-A540-7.5K-CH FR-A740-7.5K-CHTFR-A540-11K-CH FR-A740-11K-CHT FR-AAT24FR-A540-15K-CH FR-A740-15K-CHT FR-AAT24FR-A540-18.5K-CH FR-A740-18.5K-CHTFR-A540-22K-CH FR-A740-22K-CHTFR-A540-30K-CH FR-A740-30K-CHTFR-A540-37K-CH FR-A740-37K-CHTFR-A540-45K-CH FR-A740-45K-CHTFR-A540-55K-CH FR-A740-55K-CHTFR-A540L-75K-G1 FR-A740-75K-CHTFR-A540L-90K-G1 FR-A740-90K-CHTFR-A540L-110K-G1 FR-A740-110K-CHTFR-A540L-S132K FR-A740-132K-CHTFR-A540L-S160K FR-A740-160K-CHTFR-A540L-S220K FR-A740-220K-CHTFR-A540L-S250K FR-A740-250K-CHTFR-A540L-S280K FR-A740-280K-CHT-FR-A740-315K-CHT --FR-A740-355K-CHT -FR-A540L-S375K ---FR-A740-400K-CHT --FR-A740-450K-CHT --FR-A740-500K-CHT -FR-A540-CH与FR-A740-CHT外置散热片配件对比【外设散热片时使用】原有变频器更换变频器尺寸对比变频器型号外设散热片配件变频器型号外设散热片配件FR-A540-0.4K-CH FR-A5CN01 FR-A740-0.4K-CHT FR-A7CN01FR-A540-0.75K-CH FR-A5CN01 FR-A740-0.75K-CHT FR-A7CN01FR-A540-1.5K-CH FR-A5CN01 FR-A740-1.5K-CHT FR-A7CN01FR-A540-2.2K-CH FR-A5CN01 FR-A740-2.2K-CHT FR-A7CN01FR-A540-3.7K-CH FR-A5CN01 FR-A740-3.7K-CHT FR-A7CN01FR-A540-5.5K-CH FR-A5CN02 FR-A740-5.5K-CHT FR-A7CN02FR-A540-7.5K-CH FR-A5CN02 FR-A740-7.5K-CHT FR-A7CN02FR-A540-11K-CH FR-A5CN04 FR-A740-11K-CHT FR-A7CN03FR-A540-15K-CH FR-A5CN04 FR-A740-15K-CHT FR-A7CN03FR-A540-18.5K-CH FR-A5CN04 FR-A740-18.5K-CHT FR-A7CN04FR-A540-22K-CH FR-A5CN04 FR-A740-22K-CHT FR-A7CN04FR-A540-30K-CH FR-A5CN05 FR-A740-30K-CHT FR-A7CN06FR-A540-37K-CH FR-A5CN06 FR-A740-37K-CHT FR-A7CN07FR-A540-45K-CH FR-A5CN06 FR-A740-45K-CHT FR-A7CN07FR-A540-55K-CH FR-A5CN06 FR-A740-55K-CHT FR-A7CN07FR-A540L-75K-G1 MT-A5CN02 FR-A740-75K-CHT FR-A7CN08FR-A540L-90K-G1 MT-A5CN02 FR-A740-90K-CHT FR-A7CN09FR-A540L-110K-G1 MT-A5CN02 FR-A740-110K-CHT FR-A7CN10FR-A540L-S132K MT-A5CN02 FR-A740-132K-CHT FR-A7CN10FR-A540L-S160K MT-A5CN02 FR-A740-160K-CHT 无需配件FR-A540L-S220K MT-A5CN03 FR-A740-220K-CHT 无需配件FR-A540L-S250K MT-A5CN04 FR-A740-250K-CHT 无需配件FR-A540L-S280K MT-A5CN04 FR-A740-280K-CHT 无需配件--FR-A740-315K-CHT 无需配件---FR-A740-355K-CHT 无需配件-FR-A540L-375K MT-A5CN05 -----FR-A740-400K-CHT 无需配件---FR-A740-450K-CHT 无需配件---FR-A740-500K-CHT 无需配件-外型尺寸图(单位:mm)■FR-A740-0.4K,0.75K,1.5K,2.2K,3.7K-CHT(注)FR-A540-0.4K ~1.5K 没有冷却风扇。

(’)FR-A740-0.4K• 1.5K 没有冷却风扇丅 FR-A540-5.5K,7.5K-CH ■FR-A740-5.5K,7.5K-CHT■FR-A740-11K,15K-CHT■FR-A540-18.5K,22K-CH ■FR-A740-18.5K,22K-CHT■FR-A540-37K,45K,55K-CH ■FR-A740-37K,45K,55K-CHT〔随机DC电抗器FR-A540L-75K-G1用〕〔随机DC电抗器FR-HEL-H110K〕〔随机DC电抗器FR-A540L-90K用〕 〔随机DC电抗器FR-HEL-H132K〕■FR-A740-110K-CHT〔随机DC电抗器FR-A540L-110K用〕〔随机DC电抗器FR-HEL-H160K〕〔随机DC电抗器FR-A540L-S132K用〕〔随机DC电抗器FR-HEL-H185K〕Array W H DH185K 175 405 240〔随机DC 电抗器FR-A540L-S160K 用〕 〔随机DC 电抗器FR-HEL-H220K 〕〔随机DC 电抗器FR-HEL-H250K 〕M12■FR-A540L-S220K ■FR-A740-220K〔随机DC电抗器FR-A540L-S20K用〕〔随机DC电抗器FR-HEL-H280K〕■ FR-A740-250K-CHT〔随机DC 电抗器FR-A540L-S250K 用〕 〔随机DC 电抗器FR-HEL-H315K 〕W H DH315K 210 495 250■FR-A740-280K-CHT〔随机DC电抗器FR-A540L-S280K用〕〔随机DC电抗器FR-HEL-H355K〕■FR-A740-315K-CHT〔随机DC电抗器FR-HEL-H400K〕■FR-A740-355K-CHT〔随机DC电抗器FR-HEL-H450K〕■FR-A540L-S375K〔随机DC电抗器FR-A540L-S375K用〕ZYXS375K 220 250 495■FR-A740-400K-CHT■FR-A740-450K-CHT■FR-A740-500K-CHT〔随机DC电抗器FR-HEL-H500,H560,H630K〕2.接线基本的端子名称及接线方式异同参数表参数追加参数变更参数消除FREQROL-A500(L)-CH FREQROL-A700-CHT 参数号参数名称参数号注意事项0 转矩提升(手动) 01 上限频率 12 下限频率 23 基准频率 34 多段速设定(高速) 45 多段速设定(中速) 56 多段速设定(低速) 67 加速时间 78 减速时间 89 电子过电流保护 910 直流制动动作频率 1011 直流制动动作时间 1112 直流制动电压 1213 启动频率 1314 适用负载选择 1415 点动频率 1516 点动加减速时间 1617 MRS输入选择 1718 高速上限频率 1819 基准频率电压 1920 加减速基准频率 2021 加减速时间单位 2122 失速防止动作水平22 設定値9999删除23 倍速时失速防止动作水平补偿系数 2324 多段速设定(4速) 2425 多段速设定(5速) 2526 多段速设定(6速) 2627 多段速设定(7速) 2728 多段速输入补偿选择 2829 加减速曲线选择 2930 再生制动功能选择 3031 频率跳变1A 3132 频率跳变1B 3233 频率跳变2A 3334 频率跳变2B 3435 频率跳变3A 3536 频率跳变3B 3637 转速显示 3741 频率到达动作范围 4142 输出频率检测 4243 反转时输出频率检测 4344 第2加减速时间 4445 第2减速时间 4546 第2转矩提升 4647 第2V/F(基准频率) 4748 第2失速防止动作水平 4849 第2失速防止动作频率 4950 第2输出频率检测 5052 DU/PU主显示数据选择 5253 PU水平显示数据选择-PU水平显示不可选择54 FM端子功能选择 5455 频率监视基准 5556 电流监视基准 5657 再启动自由运行时间 5758 再启动上升时间 5859 遥控设定功能选择 5960 智能模式选择60 最短加减速模式、最优加减速模式、升降机模式、顺序制动模式删除61 智能模式基准电流 6162 加速时电流基准值 6263 减速时电流基准值 6364 提升模式启动频率 6465 再试选择 6566 失速防止动作降低开始频率 6667 报警发生时再试次数 6768 再试等待时间 6869 再试次数显示和消除 6970 特殊再生制动使用率70 55K以下设定范围0~30%、75K以上设定范围0~10%71 适用电机 7172 PWM频率选择72 75K以上设定范围0~6,2573 0~5V,0~10V选择73 改变端子输入信号,端子2,4输入信号可选择电流或电压74 输入滤波器时间常数 7475 复位选择/PU脱离检测/PU停止选择 7576 报警编码输出选择76 设定值3删除77 参数写入禁止选择 7778 反转防止选择 7879 操作模式选择79 A500设定为8的场合,A700设定为0即可。

相关主题