当前位置:文档之家› 标准机柜结构设计规范

标准机柜结构设计规范

Q/UTS UT斯达康通讯有限公司企业标准Q_UTSB_006A0_200419″标准机柜结构设计规范The mechanical criterion of 19 inch normal cabinets designing2005-11-15 发布 2005-11-15 实施U T斯达康通讯有限公司发布Revision HistoryUTStarcom ProprietaryNot for use or disclosure outside UTStarcom, Inc. or any of its subsidiariesExcept under prior written agreement.Intended Audience: H/W Group, Quality Assurance Group & Internal Auditors.This document is controlled electronically and any hard copy should be considered uncontrolled. This document is owned by HZ of Mechanical Development Process Team Chairperson.前言本标准制订的目的,主要是为了适应公司日益全球化发展的需要,也是为了增强公司机柜可互换性、提高公司机柜设计效率和质量、降低公司机柜研发和生产成本的需要。

本标准主要以IEC标准为主,参照了ETSI、NEBS标准对机柜性能部分的要求及NEBS标准对机柜工程安装的要求。

标准起草:徐建华目次1范围 (1)2引用标准 (1)3术语定义 (2)3.1设备实体(equipment practice) (2)3.2机柜(cabinet) (2)3.3机架(rack) (2)3.4插箱(subrack) (2)3.5机箱(chassis) (2)3.6插件(plug-in unit/model) (2)3.7机柜高度 (cabinet height) (2)3.8机柜宽度 (cabinet width) (3)3.9机柜深度 (cabinet depth) (3)3.10协调尺寸 (co-ordination dimension) (3)4机柜设计的总原则 (3)5机柜的分类及特点 (3)5.1按照使用环境分类 (3)5.2按照拼装式方式分类 (3)6机柜的基本组成 (4)6.1顶围框、底座、外柱的设计 (4)6.2前门、后门的设计 (4)6.3左、右侧板的设计 (5)6.4安装柱的设计 (5)6.5导轨的设计 (5)6.6搁板的设计 (5)6.7铭牌的设计 (5)6.8支撑脚的设计 (6)6.9脚轮的设计 (6)6.10吊环的设计 (6)7机柜设计的基本要求 (6)7.1机柜的外形尺寸、装配尺寸及机柜并架要求 (6)7.2机柜的刚度、强度和重量 (6)7.3机柜的走线要求 (6)7.4机柜使用的热环境及散热能力 (7)7.5机柜的电磁兼容能力 (7)7.6防雷击性能要求 (7)7.7机柜的防振等级要求 (7)7.8机柜稳定平衡的最大角度要求 (7)7.9机柜的防尘要求 (7)7.10机柜的包装运输要求 (7)7.11机柜的工程安装要求 (7)7.12机柜三防设计要求 (7)7.13机柜的工业造型设计要求 (7)7.14机柜的人机工程设计要求 (7)7.15机柜的防水等级要求 (8)7.16机柜的生产成本要求 (8)8机柜设计的基本准则 (8)8.1热设计准则 (8)8.2静电防护设计准则 (8)8.3EMC设计准则 (8)8.4“三防”设计准则 (9)8.5维修性设计准则 (9)8.6互换性设计准则 (10)8.7可达性设计准则 (10)8.8模块化设计准则 (10)8.9人机工程设计准则 (10)8.10防错误设计准则 (10)8.11标识设计准则 (11)9机柜的协调尺寸及公差 (11)9.1外形协调尺寸及公差 (11)9.2内部装配协调尺寸及公差 (12)9.3工程安装尺寸协调尺寸及公差 (14)10机柜空区挡板的设计 (15)10.1空区挡板的基本尺寸及公差 (15)10.2空区挡板与机柜的装配 (17)19″标准机柜结构设计规范The mechanical criterion of 19 inch normal cabinets designing1范围本标准规定了公司19″标准机柜结构设计的基本尺寸、基本性能及工程安装要求。

本标准适用于公司所有19″标准机柜的设计,并且自本标准发布日起,应当严格执行。

在没有特殊情况下,公司的19″标准机柜的设计必须依此标准为依据。

2引用标准IEC 60917-1-98电子设备机械结构设计模型化规则第一部分:总标准Modular order for the development of mechanical structures for electronic equipment practices,Part 1: generic standardIEC 60297-1-86482.6(19 in)系列机械结构尺寸第一部分:面板和构架Dimensions of mechanical structures of the 482.6mm (19 in) series,Part 1: Panels and racksIEC 60297-2-82482.6(19 in)系列机械结构尺寸第二部分:机柜和机柜的间距Dimensions of mechanical structures of the 482.6mm (19 in) series,Part 1: Cabinets and pitches of rack structuresIEC 60916-88电子、电工设备机械结构术语Terminology for mechanical structures of electrotechnical and electronic equipmentIEC 61587-99电子设备机械结构IEC 60917和 IEC 60927的试验Mechanical structures for electronic equipment–tests for IEC 60917 and IEC 60297第一部分机柜、插箱的气候、机械试验和安全特性Part 1 Climatic、mechanical tests and safety aspects for cabinets、racks、subracksand chassis第二部分机柜插箱的地震载荷试验Part 2 Seismic tests for cabinets and racksIEC 60950-99信息技术设备的安全Safety of information technical equipmentETS 300 119-1-94 设备工程;通讯机柜的欧洲标准第一部分:概述和术语Equipment Engineering (EE);Equipment telecommunications standard for equipment practice,part 1: Introduction and terminologyETS 300 119-2-94设备工程;通讯机柜的欧洲标准第二部分:机柜和机架的工程需求Equipment Engineering (EE);Equipment telecommunications standard for equipment practice,part 2: Engineering requirements for racks and cabinetsETS 300 119-3-94 设备工程;通讯机柜的欧洲标准第三部分:机柜和机架排列的工程需求Equipment Engineering (EE);Equipment telecommunications standard for equipment practice,part 3: Engineering requirements for miscellaneous racks and cabinetsGR-63-CORE-2002网络通讯设备的系统需求:物理保护Network Equipment-Building System Requirements: Physical Production3术语定义3.1 设备实体(equipment practice)电子及机电系统的壳体和安装件的机械结构,它考虑了机械部件、电器连线及电子元件之间的相互适应性。

3.2 机柜(cabinet)机柜是一种自由站立并独立支撑的用于电子设备的壳体,它可以独立使用,也可与其他机柜成组使用。

机柜可在一侧或多侧装有门和侧板,以适应不同的用途。

3.3 机架(rack)用于安装电气或电子部件,能自由站立或固定安装的结构。

3.4 插箱(subrack)供安装多个插件和印制板并可装入机柜、机架等内的一种结构箱体单元。

3.5 机箱(chassis)专为支撑辅助电气元件而设计的一种结构箱体单元,也可向插箱一样插入机柜、机架等内。

3.6 插件(plug-in unit/model)可以插入机柜、机架或插箱内部的,以导轨导向并支撑的结构单元,其包括机械支撑结构、PCB 板、接插件、导向柱、带有插拔器、指示灯、开关的面板等。

3.7 机柜高度 (cabinet height)机柜高度指的是机柜在正常工作状态下的高度,它不包括支撑脚(或脚轮)、吊环的高度。

附注:1、IEC 60297-2-82种规定,机柜的高度应包括机柜所附带的任何脚轮和支撑脚;2、ETS 300 119-2-94和ETS 300 119-3-94规定,机柜的高度应包括机柜所附带的任何脚轮和支撑脚。

3.8 机柜宽度 (cabinet width)机柜的宽度包括两种宽度,协调尺寸宽度、实际宽度。

协调尺寸宽度是机柜在工程现场中所要满足的节距线(pitch line)的协调尺寸(co-ordination dimension)的值;实际宽度是机柜左右包括侧板及侧板外表面最突出部份的实际距离。

有并柜要求的机柜,其实际宽度一定要小于协调尺寸宽度;没有并柜要求的机柜,其实际宽度不能大于协调尺寸的宽度。

3.9 机柜深度 (cabinet depth)机柜的深度定义为机柜的前、后门外表面之间的距离。

机柜的实际深度应该小于或等于机柜的协调尺寸深度。

3.10 协调尺寸 (co-ordination dimension)协调尺寸是一个不带公差的参考尺寸,主要是用于协调机柜内部结构(部)件的安装配合及机柜、电缆安装空间。