当前位置:文档之家› 诺西认证考试题库汇总题目.

诺西认证考试题库汇总题目.

what whole command is useful when conversion database from DBA format to ASC format under Br6.0A dbaem create cmd –dbfile.dba -dbinputB dbaem create cmddbfile.dba dbinputC dbaem create cmd -dbinputD dbaem create cmd dbintput DNO 5.1What file name is can be working under DBAEM (Br60 when DBA conversion ASC.A db26415.dba.B db25416.dbaC dbfile.ascD dbfile.dbaD NO 5.1What file name is can be working under DBAEM (Br80when ASC conversion DBA.A cmd27134.ascB cmd28134.ascC cmd27117.ascD cmd28117.ascD NO 5.1What’s kind files will automatic generated in your DBAEM directory when we made conversion command from ASC format to DBA format wascompletedA snx*****.ascB def*****.ascC dpm*****.ovlD rsp*****.asc DNO 5.1what is DBAEM functionuseful?A modify parameterB build new databaseC database optimizeD database conversionD NO 5.1What command is preferredwhen upgrade database fromBr70 to Br80A converfile -27*** -28***B converfile 27***.asc28***.ascC converfile -27***.asc –28***.ascD converfile 27*** 28***D NO 5.1What command is preferred when upgrade database from Br60 to Br70 A converfile -26*** -27***B converfile 26***.asc 27***.ascC converfile -26***.asc –27***.ascD converfile 26*** 27***DNO 5.1What’s kind files will automatic generated at once in your DBAEM directory when we made conversion command from ASC format to DBA format was startingA readme.txtB define.txtC dpm_.ovlD bscinfo.txtD NO 5.1Here I got one message “ERROR > bsc15.asc line 1128- SYNTAX ERROR” pleasegive the reason possible aboutthis alarm.A the parameter set wrongvalueB the object set wrong nameC the value set out of rangeD the sign set wrong symbolD NO 5.1Here I got one message “UNKNOWN ATTRIBUTE”please give the reason possible about this alarm.A the parameter set wrong valueB the object set wrong nameC the value set out of rangeD the sign set wrong symbol BNO 5.1Here I got one message “CREATE LPDLMNAME=BTSM:18/LPDLM:0:RESP="UNSUCCESSFUL_NO_MORE_LAPDPOOL_AVAILABLE" try to give the reasonpossible about this alarm.A parameter errorB symbol errorC naming errorD value out of rangeD NO 5.1Here I got one message “CREATE FHSYNAME=BTSM:12/BTS:0/FHSY: 1:RESP="UNSUCCESSFUL_TR X_FREQ_NOT_FOUND” t ry to give the reason possible aboutthis alarm.A create btsm have some errorB create bts have some errorC create trx have some errorD create channel have some error CNO 5.1Here I got one message “CREATE BTSNAME=BTSM:15/BTS:0:RESP="INVALID_SVR" try to give the reason possible aboutthis alarm.A create pcmb have someparameter set errorB create lapdm have someparameter set errorC create btsm have someparameter set errorD create bts have someparameter set errorD NO 5.1HW MSC4 OPC value is set 1001(decimal please give a correct value for match Siemens database format(hex.A 10-10B 3-233C 1-1D 233-3DYES 4.3YESHW MSC3 SPC value is set 3000(decimal please give a correct value for matchA 8-187B 30-1C 11-184D 184-11D YES 4.3YESwhich parameter need modifyby Siemens side when NT MSCchanges OPC value?A OPCB SPCC OMALD X25B YES 4.3YESwhich parameter need modify by Siemens side when HW MSC changes SPC value?A OPCB SPCC OMALD X25AYES 4.3YESwhich parameter need modify by Siemens side when NT MSC changes SS7L linkA PCMAB SS7LC SPCD Nothing need modifyB YES 4.3YESTransfer Siemens BSC to HWnew MSC, what parametermust be modified.A LAC and CIB Timer of T3212C Mel IDD OPC and SPCD YES 4.3YESTransfer Siemens BSC to HW NT MSC, can not make MTC, try to give some method of technical for troubleshooting.A reset SS7LB reset SPC and OPCC reset BSC salunameD restart BSC S/W DYES 4.3YESTransfer Siemens BSC to Ericsson MSC all SS7L can not working. Try to give some probably method of technical for troubleshooting.A reset “TSYNC” valueB reset BSC “T3122” valueC reset BSC “MSCV” valueD reset BSC “saluname”valueC YES 4.3YESTransfer Siemens BSC to HWMSC some site can not makeMOC, try to give some methodof technical for solve problem.A reset “IMSIATDT” valueB reset BTSM versionC restart BTS S/WD reset LAC or CI value byMSC sideD YES 4.3YESTransfer Siemens BSC to HW MSC; The RC O-Link can not working normally, try to give some method of technical for solve problem.A restart TRAU S/WB reset MEL IDC reset BSC “NETWTYPE”valueD restart RC server BYES 4.3YEScurrent network configuration as HWMSC1 and HWBSC1、SiemensBSC2 after transfer new SiemensBSC3 to HWMSC1, SiemensBSC3 can not make handover to HWBSC1 except HWBSC1 to SiemensBSC3, try to give some advice for solve thisproblem.A SiemensBSC3 OPC andSPC set errorB Never create target cellabout adjacent cell intraHWBSC1C HWMSC1 not createexternal handover data aboutSiemensBSC3D SiemensBSC3 BTScreation data was failC YES 4.3YEStransfer Siemens BSC to NT MSC all MOC and MTC is working now but all incoming handover (inter BSC was reject by unknown reason. What do you think about this case?A NT BSC parameter set incorrectnessB NT MSC parameter set incorrectnessC Siemens parameter set incorrectnessD Trunk links have problem BYES 4.3YESAfter transfer Siemens BSC to HW MSC the BSC O-Link can not start. The O-Link route is first Siemens BSC PCMA:0-30 nuc to HW MSC then from HW MSC nuc to Siemens own MSC, at last connection to RC server. please try to give someadvice for solve this problem.A Siemens BSC OMAL or MEL ID set incorrectnessB HW MSC NUC TS notcorrect with Siemens MSCC Siemens MSC NUC TC not correct with RC severD All possible above reasonD YES 4.3YES机;C:\Documents andSettings\CN1LF110\Desktop\7.doc在BSC 的BFAP 中只有与应的LED 一直在闪烁,请给出完成的排除故障的操作步骤。

相关主题