Setting up a VME System
Step 1 Preparation of the VME-rack
Installation of the P2 Backplane Connector
Fußzeile
2
Vorlagen-Nr./Datum
S V G A S V G A S V G A S V G A S V G A
VMCI VMCI VMEbus VMEbus
VMCI VMCI VMCI VMCI VMEbus VMEbus VMEbus VMEbus
VMEbus
Fußzeile
7
Vorlagen-Nr./Datum
Setting up a VME System
REF MONITOR
9 8 7 6 5 4 0 1 2 3
C O N F I G
VMIPMC
PROFIBUS
P 4
P 3
S V G A
S V G A
S V G A
S V G A
S V G A
C P W R D
VMCI VMCI VMEbus VMEbus
VMCI VMCI VMCI VMCI VMCI VMEbus VMEbus VMEbus VMEbus VMEbus
Slot 8: R64 memory board
S V G A
VMCI VMCI VMEbus VMEbus
VMEbus
Fußzeile
3
Vorlagen-Nr./Datum
Setting up a VME System
Verify the jumper settings of Master-CPU Harddisk / CDROM Memory board (compare with the VME Hardware manual)
After booting the system, the VxWorks prompt must appear)
2. 3. 4.
Fußzeile
6
Vorlagen-Nr./Datum
Setting up a VME System
Step 2 Installation of Slave CPUs
0
1. Configure, generate and download all INI-files with the „System configurator“ of LogiCad
Fußzeile
10
Vorlagen-Nr./Datum
Setting up a VME System
Step 7 Installation of I/O-boards
1.
Verify the jumper settings of the boards and set the proper basic adress for bus mapping
(compare with the VME Hardware manual)
Fußzeile
11
Voቤተ መጻሕፍቲ ባይዱlagen-Nr./Datum
S V G A
S V G A
S V G A
S V G A
S V G A
C P W R D
VMCI VMCI VMEbus VMEbus
VMCI VMCI VMCI VMCI VMCI VMEbus VMEbus VMEbus VMEbus VMEbus
VMCI VMEbus
VMCI VMCI VMEbus VMEbus
After booting the system, the VxWorks prompt must appear at all CPUs Check traces for errors
Fußzeile
8
Vorlagen-Nr./Datum
Setting up a VME System
Step 5 Configuring the network connection
1
2
3
4
5
6
VMIVME 7807
7
8
R64
9 10 11 12 13 14 15 16 17 18 19 20
VMIVME VMIVME 7807 7459
VMIVME VMIVME VMIVME 7807 7807 7807
Slot 0: master-CPU Slot 1: hard disk / CDROM Slot 3: Slave CPU „Target 3“ Slot 4: Slave CPU „Target 4“ Slot 5: Slave CPU „Target 5“ Slot 6: Slave CPU Target 6“ Slot 8: R64 memory board
Copy the files TCPLOAD.INI from c:\run\ini\examples c:\run\ini\ to
and edit the IP- address
Fußzeile
9
Vorlagen-Nr./Datum
Setting up a VME System
Step 6 Download Ini-files
5
Vorlagen-Nr./Datum
Setting up a VME System
Step 3 Installation of operating system
1.
Create and format a Primary DOS Partition by using a bootable ProBAS CD-ROM (CD3) Install the VxWorks operating system Install updates (CD4) Testing the minimal configuration
Step 4 Installation of Slave-CPUs
1. 2. 3. 4. 5. 6. 7.
Verify the Jumpersettings of the boards Remove the Master CPU (slot 0) Insert the first Slave-CPU to slot 0 and configure it corresponding to the manual Remove the configured Slave-CPU and insert the next slave cpu on slot 0 Proceed with the remaining Slave CPUs in the same way Insert all CPUs on the corresponding slots and power up the VME-system Testing the configuration
PASS
5
FAIL
P 3
OK
EXT SYNC
SYS
COMM
FAIL S.D.
REF ADJ
FAIL
TX
A B
8 7 6 5 4 9 0 1 2 3
GND
RX
C D
R E S E T
REF MONITOR
9 8 7 6 5 4 0 1 2 3
C O N F I G
VMIPMC
PROFIBUS
P 4
P 3
VMIVME 2540
VMIVME VMIVME 4140 3122
VMIVME
VMIVME 5136
9 8 7 6
0
1 2 3 4
PASS
5
FAIL
P 3
OK
EXT SYNC
SYS
COMM
FAIL S.D.
REF ADJ
FAIL
TX
A B
8 7 6 5 4 9 0 1 2 3
GND
RX
C D
R E S E T
CAUTION !
1. 2. Observe precautions for handling electrostatic discharge sensitive devices ! Never install VME-boards if the rack is switched on !
Fußzeile
Fußzeile
13
Vorlagen-Nr./Datum
Setting up a VME System
Step 2 Installation of minimal hardware configuration
0
1
2
3
4
5
6
7
8
R64
9 10 11 12 13 14 15 16 17 18 19 20
VMIVME VMIVME 7807 7459
Slot 0: master-CPU Slot 1: hard disk / CDROM
VMCI VMCI VMEbus VMEbus
VMCI VMEbus
VMCI VMEbus
Setting up a VME System
Step 8 Testing the entire system
1. 2. 3. 4.
Start the VME system Check Status-LEDs of all boards Check (system-) trace messages Check log-files