当前位置:文档之家› 各国插脚尺寸

各国插脚尺寸

2PIN欧洲插脚Two-pin plugs for class II appliances (Up to 2.5 A rating) According to EN50075 - Standard Sheet and IEC60083 - Standard C5Symbol Requirement(mm) Measured (mm) Symbol Requirement(mm)Measured (mm)A ≥ 16.5 I −B 25.6 - 26.6 J 3.94 – 4.06C 45 ︒K 10.0 – 11.0D R 5.0 – 6.0 L 18.5 – 19.5E 34.6 – 36.0 M ≤ 90 ︒F 13.0 – 14.4 N 0.7 – 1.7G Engagement18.0 – 19.2O ≤ 2.0G End 17.0 – 18.0 P ≥ 4.0H Within 4 mm fromengagementface≤ 4.0mmQ ≥ 18.0Above 4 mm fromengagementface≤ 3.8mmA & P only for plug with supply cord. Direct plug-in product not consider the dimensions.UK Plug Checking Form according to Figure 4 of BS1363-3Symbol Requirement(mm) Measured (mm) Symbol Requirement(mm)Measured (mm)A 25.37 max. Q 17.2-18.2B 25.37 max. R 6.22-6.48 /C 34.6 max. S 3.90-4.05D 11.05-11.18 T 6.22-6.48 /E 11.05-11.18 U 6.35 min.F R 15 min. -- V 60︒-80︒--G R 9.5 min. W 1.35-1.85H R 9.5 min. X 3.90-4.05I 22.10-22.36 Y 1.2-2.0J 22.23-23.23 Z R 0.1-1.0 -- K 1.35-1.85 a 58︒-62︒-- L 7.80-8.05 b 1.35-1.85M 58︒-62︒-- c 58︒-62︒-- N 3.90-4.05 / d 1.35-1.85O 9.2 max. e 0.2 max.P 9.5 max. f 1.35-1.85Grounding pinStandard sheet Figure 2.1 (a1) or 2.1(c)Standard sheet Figure 2.1 (e) and fig 2.4Position Required (mm) By Measurement (mm)By the gauges in Figure A1A 6.35±0.15 -B 6.35±0.15C +0.150.051.63-- D 7.92 -- P E 10.31 -- P F 17.06±0.4 - G 19.94±0.8 1 21.9 max. or 27.0 min. - 2 21.9 max. or 27.0 min. - 3 21.9 max. or 27.0 min. - 4 21.9 max. or 27.0 min.- 5 60︒ -- P 6 60︒ -- P 7 8.6 min. - 8 21.0 max. - 9 20.0±1.0 - 10 1.0 max - 118.7±0.5-Dimensions checked by gauge and measurementStandard sheet Figure 2.1Position Required (mm) By Measurement (mm) By the gauges in Figure A1 Plug type (h)R 0.35±0.05 -S 0.9±0.1 -T ≥0.60-V 6 -- PDimension Checking for Two-pin plugs of NA (15 A, 125 V)According to (NEMA WD 6-2002 Figure 1-15)Symbol Requirement (inch) Measured (inch) Symbol Requirement (inch) Measured (inch)A 0.120 - 0.130 E 0.240 - 0.260B 0.151- 0.161 F 0.307 - 0.322C 0.449 - 0.479 G 0.055 - 0.065D 0.625 - 0.718 H 0.495 - 0.505Perimeter faces to the plug blades shall not be less than 7.9 mm (intended for use withchildren’s toys) or 5.1 mm from any point of either bladeDimension Checking for Tow-pin plugs (6 A, 10 A rating)According to Fig 1 of GB 1002-2008Symbol Requirement (mm) Measured (mm) t 1.40 ~ 1.50b 6.18 ~ 6.40F 12.565 ~ 12.835E 15.65 ~ 16.35R 5.00 ~ 7.00dThis distance of live plug to engage edge ≥ 6.5dDimension Checking for Korea plugs (Two-pole plug for 3A250V) According to KSC 8305日本插脚Dimensions checked by gauge and measurementPosition Required (mm) By Measurement (mm)A <14.6B >10.8C 1.35 – 1.65D 1.35 – 1.65E -- --F -- --G 6.0 – 6.6H 6.0 – 6.6I -- --J -- --K 15.7 – 18.3L 15.7 – 18.3M -- --N -- --O -- --P 11.3 – 12.1Q 11.3 – 12.1R φ2.8 –φ3.3S >φ3.5T <0.9巴西插脚Equipment’s combined with two-pole plug (Class II) 10 A/250V a.c. (figure 13. NBR 14136: 2002)Symbol Requirement (mm) Measured (mm) Symbol Requirement (mm) Measured (mm)B 25.5 - 26.5 J 3.95 – 4.05C 90 ︒ - 92 ︒ K 10.0 – 11.0D R 5.0 – 6.0 L 19.0 – 19.7E 35.0 – 36.0 N 1.0 max.F 13.0 – 14.4 O R 2.0 -2.5G 18.8 – 19.2 ④> 3 mm①> 14 mm ⑤See above②See above ⑥See above③See above ⑦See aboveNote:1 The sketches are not intended to govern design, except as regards the dimensions shown2 Plugs can be rewirable or non-rewirableRequirements:①– The distance between the engagement face and the cord or cord guard, if any, shall be at least 14 mm②– Within this distance, the outline shall be not smaller than the engagement face.③– Within this distance, the outline shall be not larger than the engagement face.④– Insulating sleeves on the current-carrying pins are optional If the insulating sleeves are separate parts, they shall enter the plug by at least 3mm measured from the engagement face.⑤– The external diameter of the insulating sleeves shall not be larger than the diameter of the uninsulated part of the pins.⑥– To avoid damage to shutters, the ends of the pins shall show neither sharp edges nor burrs. They shall⑦– The angle of 90° represents the maximum permissible area for the orientation of the entry of the flexible cable or cord.印度插脚:Indian Plug Checking WorksheetDimension: mmSymbolRated CurrentMeasured ( ) 6A ( ) 16AA 22.22±0.15 28.6±0.15B 19.1±0.15 25.4±0.15C 7.010-7.085 8.660-8.735D 5.030-5.105 7.010-7.085E 15.77-16.94 20.47-21.64F 20.47-21.64 28.47-29.64G1) ≥7.94 ≥9.52 Note:1. “G” is the minimum distance between the pins and the perip hery of the plug.阿根廷插脚:IRAM 2063 Plug (Class II, two-pole) Checking Worksheet (IRAM 2063:1982 + Amd 1999)Symbol Requirement (mm) Measured (mm) Symbol Requirement (mm) Measured (mm)A 8.0 min. H 120±5︒B 7.92±0.1 I 13.72±0.1C 7.92±0.1 J 6.25±0.1D 6.86±0.1 K 6.25±0.1E 6.86±0.1 L 1.55±0.07F 60︒M 18.2±0.2G 60︒N Marked “N”Yes / No沙特插脚:SASO Plug Checking Form according to Figure 1 of SASO 2203。

相关主题