当前位置:文档之家› 栏杆扶手规范(Rail rail)

栏杆扶手规范(Rail rail)

栏杆扶手规范(Rail rail)栏杆扶手规范(Rail rail)The rules of handrails (2009-06-06-16:16:02) are reproducedLabel: miscellaneousMandatory provisions "general rules for civil building design" (GB50352-2005) 6.6.36.6.3 balcony, outdoor corridor, indoor corridor, inner patio, and master's houseThe protective railings should be set up in the face and outdoor staircases, and should meet the following requirements:1. The railings shall be made of solid and durable materials and can withstand the horizontal load specified by the load specification.The height of the railings should not be lower than 1.05 m when the height of the air is below 24m, and the height of the rail should not be less than 1.10m when the height of the height is 24m and 24m above (including the middle and upper houses).Note: rail height should begin from the ground floor or roof to the top of the handrail vertical height calculation, such as the bottom width is greater than or equal to 0.22 m, and height is less than or equal to 0.45 m to tread, areas step should begin from the top.3. The railings are not suitable for leaving the floor or roof 0.10 m height;04 homes, nurseries, kindergartens, primary and secondaryschools and special activities for young children the structure of the rail must be used to prevent the children climbed, when using the vertical bar for the rail, the net bar Distance should not be more than 0.11 m;05 cultural entertainment, business services, sports architecture, landscape architecture and places of children are allowed to enter the activity, when using the vertical bar for the rail, the net bar should not be more than 0.11 m.-· a compilation of mandatory standards for guardrailsIssue date: 2006-10-25Standards of construction industry of the People's Republic of ChinaHouse stair rail handrailThis standard specifies the technical requirements and inspection rules for the metal railings, metal, plastic or wooden handrails.This standard applies to the housing stair metal railings, metal, plastic or wooden handrails.2 reference standardGBJ96 residential building design specification JGJ37 architectural design general (trial)GB19 construction load specification JGJ18 rebar welding and acceptance proceduresGBJ301 construction installation engineering quality inspection standard BGJ10 reinforced concrete structure design specification.3 the termThe staircase is composed of a series of successive ladders and platforms that connect different elevations of the building plane.3.2 Step (Step) Step and Step (or no kick) Step.A long piece of accessories attached to a wall or railing.The Balustrade is arranged on the stair and the edge of the platform with a certain stiffness and safety barrier.The Stair Well is surrounded by the side of the stairway and the inner side of the platform.4 product classification4.1 the railings and handrails of metal, hard wood and composite materials according to material.5 technical requirements5.1.1 indoor common stair armrest height, since step centerline amount to an epithelial shoulds not be less than 900 ㎜. Level more than 500 ㎜ long armrest, its height should not be less than 1000 ㎜.5.1.2 sharing outdoor stair rail height should not be less than 1050 ㎜, high-level housing should not be less than 1100 ㎜.5.1.3 stairwell width is greater than 200 ㎜, unfavorable choose beautiful case children easy to climb.Clearance between rail vertical bar should not be greater than 110 ㎜.5.1.4 when the railings, handrails or the plane are transferred, they should be kept in line.5.2 material5.2.1 the specifications and quality of raw materials must conform to the design requirements and the existing provisions concerning national standards and norms.5.2.2 the raw materials for making handrails and armrests shall have the factory quality certificate or test report, and shall check in batches according to batch Numbers when coming into play. Materials that do not have the factory qualification certificate must be tested for physical and chemicalperformance according to the relevant standards, which can be used only after passing the test. Unqualified materials are strictly prohibited.5.3 structural performance5.3.1 after installation of railings, handrails and ladders, the structure bearing capacity shall be able to load 0.5 Kn/m with the horizontal load specified in GBJ9, and the maximum allowable deflection value is not5.4 appearance quality5.4.1 all railings, armrest joints (welding, screw connection) should be firm. Metal railings and metal, plastic or hard wood handrails should meet the requirements of design and existing standards.5.4.2 the surface of the product shall be clean, and shall not have the appearance defects such as burrs, welding slag and obvious hammer marks.5.4.3 the trim part of the railings must be smooth and polished, and the corners should be kept in order. No cutting marks shall be left.5.4.4 straightening of railings and handrails should be straightened, and the curve should be smooth and smooth.5.4.5 metal railings and handrails should be cleared of rust and oil stains before applying anti-rust paint. Woodenarmrests should be painted and embalmed. The lacquer layer should be even, firm, should not have obvious pile paint, leak paint etc.5.5 dimensions deviation shall be in accordance with the provisions of table 1. JG 3002.3-92 table 1It is.7 inspection rules7.1 the railings and armrest components must be inspected by the factory inspection department before they leave the factory.7.2 inspection items and methods shall be in accordance with the provisions of appendix A, housing stair railings, handrails inspection items and methods.7.3 batch and sampling7.3.1 for a batch of normal production according to the same component type and the same process.7.3.2 in appearance quality watch one by one, on the basis of random by 5%, and total sampling amount not less than 3 pieces, the batch is more than 300 pieces, random by 2%, and the total amount of sampling observation is not less than 10 appearance quality and allowable deviation measurement inspection.7.3.3 the inspection of structural performance shall be testedat random in the components of the half-year normal production.7.4 quality assessment principles:According to the evaluation, ensure project must conform to the requirements, major projects must meet their requirements, general project, classy article must be not less than 6 items conform to the requirements, the product must be not less than five requirements, product must be no less than four requirements.7.5 acceptance principles:In the railings and handrails of the sampling inspection, the rate of grade is less than 90%, and the batch of products shall be inspected according to grade one. The grade of the first grade is less than 90%, and the products shall be inspected according to the conformance products; If the qualified rate is less than 90%, the batch of products should be redoubled and the qualified rate is still less than 90%, so it should be repaired completely.After inspection of the re-built railings and handrails, all of them shall be inspected according to the conformance, and the repair methods and inspection results shall be recorded and archived.8 signs, packaging, piling and transportation8.1 the factory name (factory standard), product code, production date (year, month, day) and production team shallbe marked in obvious place, and the inspection result shall be based on the inspection result.8.2 manufacturer supply products, unit must issue a "certificate of approval" consign is used, must be marked "certificate" : the standard number, certificate number, project name, code, the weight of components, production and manufacture date, quantity, structure, performance, quality grade, etc.8.3 stair railing and armrest shall be packed into groups according to quality grade, and each group shall weigh no more than 80kg. The packing should be firm, deformed and damaged.8.4 railings and handrails should be stacked, transported and prevented from deformation according to the model.The building has the quality of the air guard railRelease date: 2007-3-20The building has the quality of the air guard rail1. The safety height of the protective handrail (panel) shall conform to the requirements of the current general principles of civil architecture design and corresponding architectural design specifications. The height of the building design specification is the clearance height above the surface layer, and the first decorative room must deduct the thickness of the corresponding surface layer. The height of the safe height should be calculated from the step surface. Note: when the rail(board) at the bottom for solid and height is less than 450 ㎜, rail inside solid surface width is greater than 65 ㎜, in fact heart body level shall be deemed to tread.2. In the case of glass protection, shall implement the "regulations of technology of architectural glass application", "building decoration engineering quality acceptance specification" and so on the current standards and regulations and the provisions of this point, as well as the regulation on administration of construction safety glass (sent to run [2003] 2003). With metal materials for protection, should comply with the specifications for design of steel structure, the construction steel structure welding technology regulations, the construction quality acceptance of steel structure engineering and the rebar welding and acceptance procedures such as the current rules and regulations and the provisions of this point.3. Residential buildings and places with children's activities, protective railings (panels) must be constructed to prevent children from climbing, and the clearance of vertical bars must meet the requirements of the relevant codes.4. When using glass as a protective railing (board), the laminated glass or tempered laminated glass must be used. When exterior decoration is the glass curtain wall, the inside should take protective measures according to the requirements of "building glass technical regulations", the height should meet the design requirements. A reliable guardrail must be used on the inside of a high body or glass falling after a collision.5. The materials, specifications, quantities and the combustion performance of the materials used in the fabrication and installation of protective railings (plates) shall meet the design requirements.6. Protective railing (board) of construction shall be in accordance with the requirements of design and specification before the construction of the "template", by the relevant units to check for the installation of large area, until they have passed the acceptance check, shall provide certificate of raw materials, the reinspection report and related inspection report.7. Guardrail height, rail spacing and installation position must meet the design requirements. Guardrail installation must be firm. The link between the hand guard and the upright post and the structure of the main body must take reliable measures, which shall not be directly buried or welded to the expansion bolt.The railings should be smooth and should not have burrs.8. The number, specification, location and connection of the embedded parts of the railings (plates) shall conform to the design requirements. Weld metal, plastic railings and handrails must be soldered. The embedded parts (or rear embedded parts) shall be connected to the node, and the lightning protection connection shall be accepted for concealed work.9. The coating of handrail (plate) should be uniform, withoutobvious wrinkling, falling, no leakage brush, and good adhesion. Metal railings descaling grade and total dry film thickness of coating should comply with the design requirements, should check the adhesion of coating and coating of examination and acceptance of the total dry film thickness of design should press when no request for construction quality acceptance of steel structure engineering, execution, and have corresponding record data.10. The construction of the next procedure shall not be carried out after the construction of the protective railings (board) has been completed, and if it is not accepted or unqualified.11. The construction of housing units should be handed over to the housing issue a railing airport protection such as reasonable use fixed number of year and the rational use of specifications, building manager (project owner or management) in the process of the use of housing should be according to the directions on the rail and airport protection for regular inspection and maintenance. When the use life exceeds the reasonable period of use determined by the design, after the inspection unit is identified, effective measures should be taken to continue the use.。

相关主题