.WR系列热电偶Series Thermocouple WR WZ系列热电阻WR Series Thermocouple册手安用装使Installation & Operation Manual安徽天康(集团)股份有限公司Anhui Tiankang (Group)Shares Co., Ltd.'.目录Index1、概述 General Description (1)2、工作原理OperationTheory1......................................................3、结构Configuration (2)4、主要技术参数Main Technical Parameters (3)5、安装及使用Installation & Operation (5)6、可能发生的故障及维修Possible Troubles & Maintenance (7)7、运输及储存Transportation &Storage (8)8、订货须知Notices in Ordering (8)9、型号命名Type Naming (9).'.1、概述General Description工业用热电偶作为温度测量和调节的传感器,通常与显示仪表等配套,以直接测量各种生产过程中-40~1600℃液体、蒸汽和气体介质以及固体表面温度;As sensor for temperature measuring and regulation, industrial-purpose thermocouple is usually connected with display meter and other meters to directly measuretemperature of liquid, vapor, gas and solid surface ranging from -40℃to 1600℃.工业用热电阻作为温度测量和调节的传感器,通常与显示仪表等配套,以直接测量各种生产过程中-200~500℃液体、蒸汽和气体介质以及固体表面温度。
As sensor for temperature measuring and regulation, industrial-purpose thermal resistance is usually connected with display meter and other meters to directly measuretemperature of liquid, vapor, gas and solid surface ranging from -200℃to 500℃.2、工作原理Operation Theory12.1热电偶工作原理Operation Theory of Thermocouple热电偶工作原理是基于两种不同成分的导体两端连接成回路,如两连接端温度不同,则在回路内产生热电流的物理现象。
热电偶由两根不同导线(热电极)A和B组成,它们的一端T1是互相焊接的,形成热电偶的测量端T1(也称工作端)。
将它插入待测温度的介质中;而热电偶的另一端T0(参比端或自由端)则与显示仪表相连,如果热电偶的测量端与参比端存在温度差,则显示仪表将指出热电偶产生的热电动势。
热电偶的热电动势随着测量端温度的升高而增大,它的大小只与热电偶的材料和热电偶两端的温度有关,而与热电级的长度、直径无关。
Thermocouple is based on physical phenomenon that two conductor of different materials is connected to form return circuit, when temperature on both contact is different,it results in thermoelectric potential in return circuit.2.2热电阻工作原理Operation Theory of Thermal Resistance热电阻是利用金属导体或半导体有温度变化时本身电阻也随着发生变化的特性来测量温度的,热电阻的受热部分(感温元件)是用细金属丝均匀地绕在绝缘材料作成的骨架上,当被测介质有温度梯度时,则所测得的温度是感温元件所在范围内介质层的平均温度。
制造热电阻的材料应具有以下特点:大的温度系数,大的电阻率,稳定的化学物理性能和良好的复现性等。
在现有的各种纯金属中,铂、铜和镍是制造热电阻的最合适的材料。
其中铂因具有易于提纯,在氧化性介质中具有高的稳定性以及良好的复现性等显著的优点,而成为制造热电阻的理想材料。
It is based on that temperature change of material results in change of its resistance. Whenresistance value changes, the working instrument will display relevant temperature.3、结构Configuration3.1感温元件直径及材料Diameter & Material of Thermal Elements3.1.1 热电偶Thermocouple.'.Tube Material热电阻3.1.2 Thermal ResistanceTube Material套管材质套管直径偶丝形式Tube DiameterFormFilament Pt100单支式 3Φ4 Φ5 ΦSimplex6 Φ 1Cr18Ni9TI 8Φ双支式4Φ 5 ΦDuplex6Φ8ΦJunction Box接线盒3.2;3.2.1接线盒供连接热电偶、热电阻参比端和显示仪表之用display thermocouple connection between reference end of and box Junction is forinstrument.Protection Class of Junction Box: IP65 IP65; 3.2.2 接线盒防护等级StructuralFigure of Junction Box 防水接线盒结构图3.2.3安装固定装置3.3 Installation & Fixing Devices.'.3.3.1 卡套螺纹接头Threaded Head with Fastener卡套固定卡套S扳手套动卡可卡套Fastener 扳手Spanner 固定卡套Fixed Fastener 可动卡套Movable FastenerOuter Diameter of Armored Thermocouple代号和尺寸铠装偶外径dCode & Size2 Φ3 ΦΦ6 Φ5 Φ4 Φ8M12×1.5 M M16×1.519 S 223.3.2 固定螺纹式Threaded Connector3.3.3 活动法兰式Movable Flange4、主要技术参数Main Technical Parameters4.1 产品执行标准Executive Standard IEC1515IEC751GB/T16839-1997JB/T8622-19974.2 测温范围及允差Measuring Range & Tolerance.'.为实际温度,允许可用温度度数表示,也可用实际温度的百分数表示,取其大者。
注:t of percentage temperature centigrade or It may be indicated with actual Notes: t is the temperature. centigrade, the bigger one is preferred.热电阻4.2.2Thermal Resistance测温范围允许偏差精度等级分度号Measuring Accuracy Class ToleranceGraduation Range(0.15+0.002)ltl ±A级Pt100+500-200~(0.30+0.005)ltlB级±Protection Class: IP654.3 防护等级:IP65常温绝缘电阻Insulation Resistance under Normal Temperature4.4热电偶Thermocouple4.4.1(直±50V,试验电压为500热电偶在环境温度为20±15℃,相对湿度不大于80% 。
Ω流)电极与外套管之间的绝缘电阻≥100M.m m Ω·less than 100Melectrode and outer tube is no Insulation resistance between, relative humidity is no more than ℃±15under condition that ambient temperatureis 2050V (D.C.).80%, and test voltage is 500±的1mMΩ表示,即为常温绝缘与热电偶长度的乘积,对于长度小于绝缘电阻用 1m计算。
热电偶按or product of insulation resistance and thermocouple length. m,The unit is MΩ·Thermocouple with length less than 1m is considered as 1m. in calculation.热电阻Thermal Resistance4.4.2(直100V,试验电压为10~15热电阻在环境温度为~35℃,相对湿度不大80% Ω流)电极与外套管之间的绝缘电阻≥100Munder Ωthan no less 100Mtube between Insulation resistance electrode and outer is, relative humidity is no more than 80%, and ℃condition that ambient temperature is 15~35test voltage is 10~100V (D.C.).热响应时间Thermal Response Time4.5所仪表的电流输出信号变化至相当于该阶跃变化的当温度出现阶跃变化时,50% 0.5需的时间,通常以τ表示.'.When step change of temperature happens, τ0.5 is used to indicate the time for current output signal of instrument changes into 50% of the step change value.4.6 公称压力Nominal Pressure一般是指室温下保护管所能承受的静态外压力而不破裂,试验压力取公称压力的1.5倍。