当前位置:文档之家› HFSS模型转换参数优化和脚本语言

HFSS模型转换参数优化和脚本语言

w
w
Solution Types/Setup
w
All Sources are migrated
w
Impedance Lines and Terminal lines are migrated.
– Impedance lines will be ignored for Driven Terminal solutions, terminal lines will be ignored for Driven Modal solution.
Overview of Ansoft HFSS 9
Legacy Project Migration Optimetrics™ Scripting Language
Ansoft Corporation Four Station Square, Suite 200 Pittsburgh, PA 15219
Migrating a Legacy HFSS Project
w w w
w
w
On the File menu, click Open. Browse to the HFSS 8.5 projects’ directory, and open the *.pjt folder of a specific project. Select Ansoft Legacy EM Projects (*.cls) from the files of type pull-down list. Select the *.cls file in the project directory and click Open. The project appears in the HFSS v9.0 interface. NOTE: The HFSS v9.0 project is saved as a *.hfss file, and it is located in the user’s chosen project directory.
parameter list
Parameter Sweep Results
f = 1 GHz
Z0 (goal)
r_inner
Optimization I: Desire |(re(Z0))| ~= 50 Ohms
Variables: .1 <= r_inner <= .3 r_inner(initial) = .11mm
w
After importation data can be plotted using the Results Post-processor
Importing data from HFSS v8.5
w w w
Right-click on Analysis in Project tree, select ‘Import Data’ or ‘Import Table’ From the Imported Data window, select either Import Solution to Load File Browse to the specific format file After the ‘Load File’ step, select the type of ‘Available Solutions’ desired (e.g. adaptive1,…, sweep1), and click ‘OK’. The selected solution data is placed in the ‘Imported Data’ window under ‘Current Imports’. Click ‘OK’ again to end the importation process. The user will be able to view or plot this imported data in the 2D Report editor.
w w w
w
Calibration lines are not migrated
w
w
Projects that contain terminal lines are migrated to Driven Terminal solution projects Current meshes are not migrated, only initial mesh is. Impedance-only and emissionsonly solutions are not migrated. Saving dominant-only or higherorder-only mode S-matrix entries are not migrated For frequency sweeps, the Number of Steps value is migrated to the corresponding Step Size value The total number of requested adaptive passes in the legacy project is migrated as the Maximum Number of Passes
Goal: abs(re(Z0))-50<=.01
Optimization I: Cost VS Iteration
abs(re(Z0))-50
Quasi-Newton initial r_inner = .11mm optimized r_inner ~= .21mm
Optimization II: |S11|<=.01 at 20 GHz
w w w w
Parametric Sweeps. Optimization Sensitivity Analysis Statistical analysis
w
Any created variables can be used in an Optimetrics solution
w w w
Dimension Material Property Frequency
w
What is Migrated?
w
Geometry
w
All geometry is migrated
w
Geometry history is not migrated
w
Materials
w
All Materials are migrated
w w
w
Boundaries
w
w
User defined materials are migrated. Functional material properties are migrated. Nonlinear materials with magnetic saturation values greater than zero are migrated as ferrite materials.
Most Boundaries are migrated
w
Boundaries assigned to named interface selections or rectangle selections are not migrated.
What is Migrated con’t?
w
Sources
Legacy Solutions
w
Solution data is not translated directly; HFSS projects must be resolved in v9.0.
w
HFSS v9.0 simulation results are located in the user’s chosen project directory, in a folder called <project_name>.hfssresults.
w
w
w w
Optimetrics
TM
Ansoft HFSS 9 OptimetricsTM Overview
w
w
Optimetrics is now fully integrated into the HFSSv9 Graphical User Interface Optimetrics now contains 4 functionalities
Written by Yianni Antoniadis Shu Li Brian Gray
Legacy Project Migration
Legacy Project Migration
w w
w w
Байду номын сангаас
Migration or re-classification of HFSS v8.5 projects to HFSS v9.0 is easily done using the Ansoft Legacy EM .cls file. When migrating a legacy HFSS project - a project created in Ansoft HFSS version 8.5 or earlier - virtually all of the project’s preprocessing data is migrated. Solution results are not migrated directly; however, HFSSv8.5 solution data will be available for plotting and tabular purposes. Optimetrics setup data are not migrated; however, the nominal model created for Optimetrics will be available in HFSSv9.
相关主题