当前位置:文档之家› 施工电梯平台计算书

施工电梯平台计算书

一、脚手架参数二、荷载设计扣件式脚手架计算书0.796计算简图:立面图剖面图三、纵向水平杆验算纵、横向水平杆布置承载能力极限状态q=1.2×(0.033+G kjb ×l b /(n+1))+1.4×G kjj ×l b /(n+1)=1.2*(0.033+0.1*0.8/(2+1))+1.4*3.6*0.8/(2+1)=kN/m正常使用极限状态q'=(0.033+G kjb ×l b /(n+1))+G k ×l b /(n+1)=(0.033+0.1*0.8/(2+1))+3.6*0.8/(2+1)=kN/m计算简图如下:纵、横向水平杆布置方式纵向水平杆在上横向水平杆上纵向水平杆根数n 2横杆弹性模量E(N/mm2)206000横杆截面抵抗矩W(mm 3)W(mm3)4490横杆抗弯强度设计值[f](N/mm2)205横杆截面惯性矩I(mm4)107800.0721.0201、抗弯验算M max =0.1ql a 2=0.1*0.0716*1.5^2=kN·m σ=M max /W=0.01611*10^6/4490 =N/mm 2205N/mm22、挠度验算νmax =0.677q'la 4/(100EI)=0.667*1.01966666666667*1500^4/(100*206000*107800)=mm νmax =mmmin[la/150,10]=min[1500/150 , 10] =mm3、支座反力计算承载能力极限状态R max =1.1ql a =1.1*0.0716*1.5=kN正常使用极限状态R max '=1.1q'l a =1.1*1.01966666666667*1.5=kN四、横向水平杆验算承载能力极限状态由上节可知F 1=R max =kNq=1.2×0.033=0.04kN/m 正常使用极限状态由上节可知F 1'=R max '=kNq'=0.033kN/m1、抗弯验算计算简图如下:1.5501.550≤[ν]=10.000满足要求!0.1180.0163.588≤[f]=满足要求!1.6820.1181.6820.11814kN0.11814kNa = lb /3 =0.8/3 =mM max = q a =(0.11814+0.04)*(0.8/3) =kN·m σ=M max /W=0.0421706666666667*10^6/4490 =N/mm2205N/mm22、挠度验算计算简图如下:KNKNνmax=mm≤[ν]=min[l b /150,10]=MIN(800/150,10)=mm3、支座反力计算l baaa-0.042-0.0428001.6821.682弯矩图(kN·m)0.2670.0429.392≤[f]=满足要求!νmax =(1.68245+0.033)*0.266666666666667(3*0.8^2-4*0.266666666666667^2)24*0.206*0.1078νmax =0.45745 1.6355555560.5329632800l b-1.404νmax =Fa (3l^2-4a^2)24EI1.4045.333满足要求!承载能力极限状态R max =KN五、扣件抗滑承载力验算扣件抗滑承载力验算:纵向水平杆:R max =0.11814/2 =KN 0.85*8 =KN 横向水平杆:R max =0.15114/2 =KN0.85*8 =KN六、荷载计算立杆静荷载计算1、立杆承受的结构自重标准值N G1k单外立杆:N G1k =(gk+l a ×n/2×0.033/h)×H=(0.129+1.5*2/2*0.033/1.8)*26 =KN单内立杆:N G1k =KN2、脚手板的自重标准值N G2k1单外立杆:N G2k1=(H/h+1)×la×lb×Gkjb×1/2/2=(26/1.8+1)*1.5*0.8*0.1*1/2/2 =KN1/2表示脚手板2步1设单内立杆:N G2k1=KN3、栏杆与挡脚板自重标准值N G2k2单外立杆:N G2k2=(H/h+1)×la×Gkdb×1/2=(26/1.8+1)*1.5*0.14*1/2 =KN1/2表示档脚板2步1设单内立杆:N G2k2=KN4、围护材料的自重标准值N G2k3单外立杆:N G2k3=G kmw ×la×H=0.01*1.5*26 =KN构配件自重标准值N G2k 总计单外立杆:N G2k =N G2k1+N G2k2+N G2k3=0.463333333333333+1.6216KN0.059≤Rc= 6.8000.076≤Rc=6.8000.151满足要求!0.3902.4754.0694.0690.4630.4631.6221.622单内立杆:N G2k =N G2k1 =KN立杆施工活荷载计算外立杆:N Q1k =la×l b ×(n jj ×G kjj +n zj ×G kzj )/2= 1.5*0.8*(1*3.6+1*3.6)/2 =KN内立杆:N Q1k =KN组合风荷载作用下单立杆轴向力:单外立杆:N=1.2×(N G1k + N G2k )+0.9×1.4×N Q1k = 1.2*(4.069+2.475)+0.9*1.4*4.32 =KN 单内立杆:N=1.2×(N G1k + N G2k )+0.9×1.4×N Q1k =1.2*(4.069+0.463333333333333)+0.9*1KN七、立杆稳定性验算1、立杆长细比验算立杆计算长度l 0=Kμh= 1.0*1.5*1.8 =m 长细比λ=l0/i=2.7*10^3/15.9 =≤立杆计算长度l 0=kμh= 1.15*1.5*1.8 =m长细比λ=l 0/i=3.105*10^3/15.9 =查《规范》表A 得,φ=2、立杆稳定性验算不组合风荷载作用单立杆的轴心压力设计值N=1.2(N G1k +N G2k )+1.4N Q1k = 1.2*(4.069+2.475)+1.4*4.32 =KNσ=N/(φA)=13900.8/(0.189*502) =N/mm2205N/mm2组合风荷载作用单立杆的轴心压力设计值N=1.2(N G1k +N G2k )+0.9×1.4N Q1k = 1.2*(4.069+2.475)+0.9*1.4*4.32 =KN M w =0.9×1.4×M wk =0.9×1.4×ωk l a h 2/10 =0.9*1.4*0.25*1.5*1.8^2/10 =kN·mσ=N/(φA)+ M w /W=13296/(0.189*502)+153090/4490=N/mm2N/mm20.4634.3204.32013.29610.8820.18913.901146.512≤[f]=满足要求!13.2962.700169.811210.000满足要求!3.105195.2830.153174.234≤[f]=205.000八、脚手架架体高度验算不组合风荷载作用H s1=(φAf-(1.2N G2k +1.4N Q1k ))×H/(1.2N G1k )==(0.189*502*205*10^(-3)-(1.2*2.475+1.4*4.32))*26/(1.2*4.069)=m组合风荷载作用H s2=(φAf-(1.2N G2k +0.9×1.4×(N Q1k +M wk φA/W)))×H/(1.2N G1k )=(φAf-(1.2N G2k +0.9×1.4×N Q1k +M w φA/W))×H/(1.2N G1k )=(0.189*502*205*10^(-3)-(1.2*2.475+0.9*1.4*4.069+0.15309*1000*0.189*502/4490)) *26/(1.2*4.069)Hs=m>H=m九、连墙件承载力验算N lw =1.4×ωk ×2×h×2×l a = 1.4*0.332*2*1.8*2*1.5 =kN长细比λ=l 0/i=800/15.9 =查《规范》表A.0.6得,φ=(N lw +N 0)/(φAc)=(5.01984+3)*10^3/(0.852*502)=N/mm2≤0.85 ×[f]=0.85*205=N/mm2扣件抗滑承载力验算:N lw +N 0=5.01984+3 =kN≤0.85*12.0 =kN十、立杆地基承载力验算立杆的地基承载力要求立杆基础底面积的平均压力应满足下式要求P k =N k/A≤f g式中:P k --脚手架立杆基础底面处的平均压力标准值N k --上部结构传至基础顶面的轴向力标准值N k =N G +N Q =KN55.54843.22726.000满足要求!满足要求!5.02050.3140.85218.751174.250满足要求!8.02010.200满足要求!13.901立杆底部铺垫6m长的M12槽钢,板面受力按照1m板带的分散作用力计算。

作用在地下室顶板面的荷载为:*3/6=KN/m2。

,承载力设计值(fg)为KN/m2。

P k =N k /A=KN/m2。

≤f g =KN/m2。

地下室顶板20.006.9520.00满足要求!13.90 6.9562 07800 4490。

相关主题