当前位置:
文档之家› 10WLED泛光灯IES文件
10WLED泛光灯IES文件
House Side
2
1
0
Street Side
1
2
-2
-1
0 Horizontal S/MH
1
2
Installation Correction 5m 1.000 6m 0.694 7m 0.510 8m 0.391 9m 0.309 10 m 0.250 11 m 0.207 12 m 0.174 13 m 0.148 14 m 0.128 15 m 0.111 16 m 0.098
Distribution Curve of Meridian
-/+180 -150 -120 150 120
Conical Intensity Distribution Curve of Max Intensity
c180 c210 c240 c150 c120
-90 74 148 222 296 -30 370 0 30
γ Range: γ Interval: Test Date: Test Time: 0-90 Degree 0.9 Degree 2011-10-25 19:16:28 Temperature: 25 Celsius Humidity: 65% Test No.: Tester:
SSP6316-D50: Lamp Intensity Spatial Distribution of Tester
Vertical S/MH
(95%) 13.43 (50%) 7.07
(90%) 12.73 (40%) 5.66
(80%) 11.31 (30%) 4.24
(70%) 9.90 (20%) 2.83
(60%) 8.48 (10%) 1.41
SSP6316-D50: Lamp Intensity Spatial Distribution of Tester
20% 30% 40% 50% 60% 70% 80% 90%
73 110 146 183 220 256 293 329
CIE: cut-off CIE: short-narrow extension
Imax: 366(H2.5,V14.2) Unit: cd
Horizontal Degree (DEG)
γ180
170
160 150 140 130 120 110 100
Road Lamp Type
CIE: CIE:
cut-off short-narrow extension IES: cut-off IES: II-very short Max.At80: 7.82cd/klm Max.At90: 7.0619cd/klm Isocandela Curve(Round Net) Intensity Unit cd Imax = 100% 366 90% 330 80% 293 70% 257 60% 220 50% 183 40% 147 30% 110 20% 74 10% 37
SSP6316-D50: Lamp Intensity Spatial Distribution of Tester
Page 1/8
Photometric Data of Lamp
Lamp Description
Lamp Name: 10w Lamp Type: Light Type: Light Standard: Lamp Size: Rated V oltage: Light Number: Light Area: Lamp Weight: Rated Power: Rated Flux: Light Flux:
Temperature: 25 Celsius Humidity: 65% Test No.: Tester:
SSP6316-D50: Lamp Intensity Spatial Distribution of Tester
Page 6/8
Isocandela Curve of Lamp
Lamp Description
Lamp Name: 10w Lamp Type: Light Type: Light Standard: Lamp Size: Rated V oltage: Light Number: Light Area: Lamp Weight: Rated Power: Rated Flux: Light Flux:
γ Range: γ Interval: Test Date: Test Time:
0-90 Degree 0.9 Degree 2011-10-25 19:16:28
Temperature: 25 Celsius Humidity: 65% Test No.: Tester:
SSP6316-D50: Lamp Intensity Spatial Distribution of Tester
1.75 2 -3 -2 -1 0 1 2 3
Imax: 366 Unit: cd
c Range: 0-360 Degree c Interval: 10 Degree Test Speed: Fast Test Distance: 5 m Note:
-2.25
2.25
Horizontal S/MH
270
285
300
315
330
345
C0
15
30
45
60
75
90
80 70 60 50 40 30 20
House Side
γ0
10
Street Side
c Range: 0-360 Degree c Interval: 10 Degree Test Speed: Fast Test Distance: 5 m Note:
SSP6316-D50: Lamp Intensity Spatial Distribution of Tester
Page 3/8
Isocandela Curve of Road Lamp (Round Net Curve)
Lamp Description
Lamp Name: 10w Lamp Type: Light Type: Light Standard: Lamp Size: Rated V oltage: Light Number: Light Area: Lamp Weight: Rated Power: Rated Flux: Light Flux:
Utilization Factor Curve of Road Lamp
HoБайду номын сангаасse Side
Horizontal Isophotes Curve
Horizontal Absolute Isophotes Curve
Height of calculation: 5.00 m, Illumination in the vertical of Lamp: 14.14 lx If Height of Installation is not equal to Height of Calculation, please calculate by table of Correction Factor
90
Illumination Cone Curve
H[m] Diameter[m] Illuminance[lx]
1.0
353.84 353.22 88.46 88.31 39.32 39.25 22.12 22.08 14.15 14.13 C0-C180 C90-C270
2.0
3.0
4.0
5.0
Page 5/8
Isocandela Curve of Lamp
Lamp Description
Lamp Name: 10w Lamp Type: Light Type: Light Standard: Lamp Size: Rated V oltage: Light Number: Light Area: Lamp Weight: Rated Power: Rated Flux: Light Flux:
Measured Data of Lamp
V oltage: 225.5 V Total Flux Lamp Efficiency Peak Intensity Half-Intensity Angle Upward Light Ratio Upward Street Side Upward House Side Flash Area(76°) Current: 0.084 A 816.15 lm 0.00% 365.88 cd 97.2° 0 0 0 0 cm2 Power: 10.6 W Central Intensity Light Efficiency Location of Peak(c,γ) Beam Angle Downward Light Ratio Downward Street Side Downward House Side Discomfort Glare(SLI) Power Factor: 0.556 353.53 cd 77.00 lm/W (80.0°, 14.4°) 115.2° 100% 430.12 lm 386.03 lm 0
Page 4/8
Lamp Utilization Factor Curve
Utilization Factor(%) 100 Elevation Legend 0.0° 90 5.0° 10.0° 80 15.0° 70 20.0° 60 50 40 30 20 10 0 2 1 0 1 Street Side 2 3 4 Horizontal S/MH
90