当前位置:文档之家› 台湾winner插装阀

台湾winner插装阀

TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 30 Cavity-Tooling: 08W-2Installation torque: 25-35Weight: 0.13Z2A2 Ports 、20 Watt. CoilNon-adjustableNkgNm l/min bar01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-ClosedNo Reverse Flow Energized1210864240302010P r e s s u r e - P (b a r )Flow-Q(l/min)14②t o ①TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 08W-2Installation torque: 25-35 Weight: 0.13 Z2A2 Ports 、20 Watt. CoilNon-adjustable N kg Nm l/min bar642503020100P r e s s u r e - P (b a r )Flow-Q(l/min)01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 210 bar 90 % of nominal8②t o ①Normally-ClosedNo Reverse Flow Energized40TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 10W-2Installation torque: 35-45 Weight: 0.16Z2A2 Ports 、20 Watt. CoilNon-adjustable NkgNml/minbar01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-ClosedNo Reverse Flow EnergizedFlow-Q(l/min)P r e s s u r e - P (b a r )102060802468101230405070②t o ①TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 12W-2Installation torque: 45-55 Weight: 0.23Z2A2 Ports 、20 Watt. CoilNon-adjustable NkgNm l/minbar12108642150120906030P r e s s u r e - P (b a r )Flow-Q(l/min)01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominal②t o ①Normally-ClosedNo Reverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 16W-2Installation torque: 60-70 Weight: 0.35 Z2A 2 Ports 、20 Watt. CoilNon-adjustable Nkg Nm l/minbar12108642150120906030P r e s s u r e - P (b a r )Flow-Q(l/min)01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominal②t o ①Normally-ClosedNo Reverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 17E-2Installation torque: 45-55 Weight: 0.22Z2A2 Ports 、20 Watt. CoilNon-adjustableNkgNm l/min bar01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalFlow-Q(l/min)P r e s s u r e - P (b a r )102060802468101230405070②t o ①Normally-ClosedNo Reverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 21E-2Installation torque: 70-90 Weight: 0.35Z2A2 Ports 、20 Watt. CoilNon-adjustableNkgNm l/min bar01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalFlow-Q(l/min)P r e s s u r e - P (b a r )3060901201502468101214②t o ①Normally-ClosedNo Reverse Flow EnergizedSOLENOID OPERATED VALVES(Pilot Operated)TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 13A-2Installation torque: 25-35 Weight: 0.13 Z2A2 Ports 、20 Watt. CoilNon-adjustable N kgNm l/minbar642503020100P r e s s u r e - P (b a r )Flow-Q(l/min)01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute (3 drops/minute) max.at 210 bar 90 % of nominal8②t o ①Normally-ClosedNo Reverse Flow Energized40GENERAL INDEXSOLENOID OPERATED VALVESTECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 250Rated flow: 20 Cavity-Tooling: 08W-2Installation torque: 25-35 Weight: 0.13Z2A2 Ports 、20 Watt. CoilLkgNm l/min bar01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute (3 drops/minute) max.at 250 bar 90 % of nominalFlow-Q(l/min)P r e s s u r e - P (b a r )51015202524681012142 t o1Normally-ClosedNo Reverse Flow EnergizedPULL STYPE(CABLE OPERATED)TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 08W-2Installation torque: 25-35Weight: 0.132A2 Ports 、20 Watt. CoilkgNm l/min bar 01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalWhen de-energized, the valve acts as a check vlave,allowing flow from ①to ②,while blocking flow from ②to ①.When energized,the cartridge's poppet lifts to Normally-ClosedNo Reverse Flow EnergizedN Non-adjustable ZOPTIONSFlow-Q(l/min)14106240②t o ①16P r e s s u r e - P (b a r )1020304812TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 10W-2Installation torque: 35-45 Weight: 0.162A2 Ports 、20 Watt. CoilkgNm l/min bar01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalWhen de-energized, the valve acts as a check vlave,allowing flow from ①to ②,while blocking flow from ②to ①.When energized,the cartridge's poppet lifts to Normally-ClosedNo Reverse Flow Energized1210864280604020P r e s s u r e - P (b a r )Flow-Q(l/min)14②t o①N Non-adjustable ZOPTIONSTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 12W-2Installation torque: 45-55 Weight: 0.232A2 Ports 、20 Watt. CoilkgNm l/minbar30252015105150120906030P r e s s u r e - P (b a r )Flow-Q(l/min)01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalWhen de-energized, the valve acts as a check vlave,allowing flow from ①to ②,while blocking flow from ②to ①.When energized,the cartridge's poppet lifts to ②to ①Normally-ClosedNo Reverse Flow EnergizedN Non-adjustable ZOPTIONSTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 16W-2Installation torque: 60-70 Weight: 0.352A2 Ports 、20 Watt. CoilkgNm l/minbar30252015105150120906030P r e s s u r e - P (b a r )Flow-Q(l/min)01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalWhen de-energized, the valve acts as a check vlave,allowing flow from ①to ②,while blocking flow from ②to ①.When energized,the cartridge's poppet lifts to ②to ①Normally-ClosedNo Reverse Flow EnergizedNNon-adjustableZOPTIONSTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 17E-2Installation torque: 45-55 Weight: 0.222A2 Ports 、20 Watt. CoilkgNm l/minbar 01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalWhen de-energized, the valve acts as a check vlave,allowing flow from ①to ②,while blocking flow from ②to ①.When energized,the cartridge's poppet lifts to Normally-ClosedNo Reverse Flow EnergizedNNon-adjustableZOPTIONS②t o①14Flow-Q(l/min)P r e s s u r e - P (b a r )2040608024681012TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 21E-2Installation torque: 70-90 Weight: 0.35Z2A2 Ports 、20 Watt. CoilNon-adjustableNkgNm l/minbar30252015105150120906030P r e s s u r e - P (b a r )Flow-Q(l/min)01Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalWhen de-energized, the valve acts as a check vlave,allowing flow from ①to ②,while blocking flow from ②to ①.When energized,the cartridge's poppet lifts to ②to ①Normally-ClosedNo Reverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 30 Cavity-Tooling: 08W-2Installation torque: 25-35 Weight: 0.112A2 Ports 、20 Watt. CoilkgNm l/min bar02Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 210 bar 90 % of nominalNormally-OpenNo Reverse Flow De-energized40②t o ①8Flow-Q(l/min)P r e s s u r e - P (b a r )102030246Push StyleN Non-adjustable ZOPTIONS101214TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 08W-2Installation torque: 25-35 Weight: 0.132A2 Ports 、20 Watt. CoilkgNm l/min bar02Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 210 bar 90 % of nominalNormally-OpenNo Reverse Flow De-energized40②t o ①8Flow-Q(l/min)P r e s s u r e - P (b a r )010203050246Push StyleN Non-adjustable ZOPTIONSTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 10W-2Installation torque: 35-45 Weight: 0.162A2 Ports 、20 Watt. CoilkgNml/minbar02Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-OpenNo Reverse Flow De-energized②t o ①705040301210864280602010P r e s s u r e - P (b a r )Flow-Q(l/min)OPTIONSZNon-adjustable N Push StyleTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 12W-2Installation torque: 45-55 Weight: 0.232A2 Ports 、20 Watt. CoilkgNm l/min bar02Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-OpenNo Reverse Flow De-energized②t o ①Flow-Q(l/min)P r e s s u r e - P (b a r )30609012015024681012Push StyleN Non-adjustable ZOPTIONSTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 16W-2Installation torque: 60-70 Weight: 0.352A2 Ports 、20 Watt. Coilkg Nm l/minbar02Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-OpenNo Reverse Flow De-energized12108642150120906030P r e s s u r e - P (b a r )Flow-Q(l/min)②t o ①N Non-adjustable ZOPTIONSTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 17E-2Installation torque: 45-55 Weight: 0.222A2 Ports 、20 Watt. Coilkg Nm l/minbar02Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-OpenNo Reverse Flow De-energizedFlow-Q(l/min)P r e s s u r e - P (b a r )102060802468101230405070②t o ①Push StyleN Non-adjustable ZOPTIONSTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 21E-2Installation torque: 70-90 Weight: 0.352A2 Ports 、20 Watt. CoilkgNml/minbar02Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-OpenNo Reverse Flow De-energized②t o ①Flow-Q(l/min)P r e s s u r e - P (b a r )30609012015024681012OPTIONSZNon-adjustable N Push StylePTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 13A-2Installation torque: 25-35 Weight: 0.142A2 Ports 、20 Watt. CoilkgNm l/minbar02Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute (3 drops/minute) max.at 210 bar 90 % of nominalNormally-OpenNo Reverse Flow De-energized40②t o ①8Flow-Q(l/min)P r e s s u r e - P (b a r )010203050246Push StyleN Non-adjustable ZOPTIONS(Pilot Operated)SOLENOID OPERATED VALVESGENERAL INDEXTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 08W-2Installation torque: 45-55 Weight: 0.132A2 Ports 、20 Watt. CoilkgNm l/min bar03Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-Closed,Reverse FlowEnergized,Nose-in,Side-out OperationNNon-adjustableZOPTIONSFlow-Q(l/min)P r e s s u r e - P (b a r )102030405101520①t o②TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 17E-2Installation torque: 45-55 Weight: 0.222A2 Ports 、20 Watt. CoilkgNml/min bar03Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-Closed,Reverse FlowEnergized,Nose-in,Side-out OperationNNon-adjustableZOPTIONSFlow-Q(l/min)①t o ②7060P r e s s u r e - P (b a r )102030405051015TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 21E-2Installation torque: 70-90 Weight: 0.352A2 Ports 、20 Watt. CoilkgNm l/minbar 03Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute (3 drops/minute) max.at 350 bar 90 % of nominalNormally-Closed,Reverse FlowEnergized,Nose-in,Side-out OperationNNon-adjustableZOPTIONSFlow-Q(l/min)20①t o②P r e s s u r e - P (b a r )30609012015051015TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 260 Cavity-Tooling: 04E-2Installation torque: 110-130 Weight: 1.132A2 Ports 、20 Watt. Coilkg Nm l/minbar03Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute (3 drops/minute) max.at 350 bar 90 % of nominalNormally-Closed,Reverse FlowEnergized,Nose-in,Side-out OperationNNon-adjustableZOPTIONS12①to ②Flow-Q(l/min)P r e s s u r e - P (b a r )060120180240300369TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 08W-2Installation torque: 25-35 Weight: 0.132A2 Ports 、20 Watt. CoilkgNm l/min bar151055040302010P r e s s u r e - P (b a r )Flow-Q(l/min)04Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separatelyMounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-Open,Reverse FlowDe-energized ,Nose-in,Side-out Operation20OPTIONSZNon-adjustable N Push Style①t o ②TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 260 Cavity-Tooling: 04E-2Installation torque: 110-130 Weight: 1.132A2 Ports 、20 Watt. Coilkg Nm l/minbar963300240180120600P r e s s u r e - P (b a r )Flow-Q(l/min)04Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute (3 drops/minute) max.at 350 bar 90 % of nominal①t o ②Normally-Open,Reverse FlowDe-energized ,Nose-in,Side-out Operation12OPTIONSZNon-adjustable N Push StyleTECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 30 Cavity-Tooling: 08W-2Installation torque: 25-35Weight: 0.13Z2A2 Ports 、20 Watt. CoilNon-adjustableNkgNm l/min bar05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-ClosedReverse Flow Energized1210864240302010P r e s s u r e - P (b a r )Flow-Q(l/min)14②t o ①TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 08W-2Installation torque: 25-35 Weight: 0.13 Z2A2 Ports 、20 Watt. CoilNon-adjustable N kg Nm l/min bar05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 210 bar 90 % of nominalNormally-ClosedReverse Flow Energized②to ①Flow-Q(l/min)P r e s s u r e - P (b a r )102030405024681012TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 10W-2Installation torque: 35-45 Weight: 0.16Z2A2 Ports 、20 Watt. CoilNon-adjustable NkgNml/minbar05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-ClosedReverse Flow EnergizedFlow-Q(l/min)P r e s s u r e - P (b a r )102060802468101230405070②t o ①TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 12W-2Installation torque: 45-55 Weight: 0.23 Z2A2 Ports 、20 Watt. CoilNon-adjustable N kg Nml/minbar12108642150120906030P r e s s u r e - P (b a r )Flow-Q(l/min)05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominal②t o ①Normally-ClosedReverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 16W-2Installation torque: 60-70 Weight: 0.35 Z2A 2 Ports 、20 Watt. CoilNon-adjustable N kg Nm l/minbar12108642150120906030P r e s s u r e - P (b a r )Flow-Q(l/min)05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominal②t o ①Normally-ClosedReverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 17E-2Installation torque: 45-55 Weight: 0.22Z2A2 Ports 、20 Watt. CoilNon-adjustableNkgNm l/min bar05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalFlow-Q(l/min)P r e s s u r e - P (b a r )102060802468101230405070②t o ①Normally-ClosedReverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 21E-2Installation torque: 70-90 Weight: 0.35Z2A2 Ports 、20 Watt. CoilNon-adjustableNkgNml/minbar05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalFlow-Q(l/min)P r e s s u r e - P (b a r )3060901201502468101214②t o ①Normally-ClosedReverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 08W-2Installation torque: 25-35Weight: 0.132A2 Ports 、20 Watt. CoilkgNm l/min bar 05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-ClosedReverse Flow EnergizedN Non-adjustable ZOPTIONSFlow-Q(l/min)14106240②t o ①16P r e s s u r e - P (b a r )1020304812TECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 70 Cavity-Tooling: 17E-2Installation torque: 45-55 Weight: 0.222A2 Ports 、20 Watt. CoilkgNm l/minbar 05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or betterMinimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-ClosedReverse Flow EnergizedNNon-adjustableZOPTIONS②t o①14Flow-Q(l/min)P r e s s u r e - P (b a r )2040608024681012TECHNICAL DATASTRUCTUREXOPERATIONOPTIONSYMax.Operating pressure: 350 Rated flow: 150 Cavity-Tooling: 21E-2Installation torque: 70-90 Weight: 0.35Z2A2 Ports 、20 Watt. CoilNon-adjustableNkg Nm l/minbar05Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalFlow-Q(l/min)P r e s s u r e - P (b a r )3060901201505101520253035Normally-ClosedReverse Flow EnergizedTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 30 Cavity-Tooling: 08W-2Installation torque: 25-35Weight: 0.132A2 Ports 、20 Watt. CoilkgNm l/min bar06Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-OpenReverse Flow De-Energized1210864240302010P r e s s u r e - P (b a r )Flow-Q(l/min)14②t o ①Push StyleN Non-adjustable ZOPTIONSTECHNICAL DATASTRUCTUREXOPERATIONYMax.Operating pressure: 350 Rated flow: 40 Cavity-Tooling: 08W-2Installation torque: 25-35Weight: 0.132A2 Ports 、20 Watt. CoilkgNm l/min bar06Fluids-Temperatures: -40~120Internal Leakage:Filtration: 25 μm nominal or better Minimun Voltage Required:Coils must be ordered separately Mounting Position:℃unrestricted0.15cc/minute(3 drops/minute) max.at 350 bar 90 % of nominalNormally-OpenReverse Flow De-Energized2 t o114121086425040302010P r e s s u r e - P (b a r )Flow-Q(l/min)Push StyleN Non-adjustable ZOPTIONS。

相关主题