生活垃圾焚烧发电项目电气设备介绍-CAL-FENGHAI-(2020YEAR-YICAI)_JINGBIAN生活垃圾焚烧发电项目电气设备介绍Introduction of electrical equipments of MSW power plant主要电气设备 Main electrical equipments为了满足用电设备对电力的要求和保证电力系统运行的安全稳定和经济性,发电厂电气部分的主要工作是启、停机组,调整负荷,切换设备和线路,不断监视主要设备的运行,发生异常和故障时及时处理等。
以上所有的工作都是靠操作主要电气设备来完成的。
本厂主要电气设备如下:In order to satisfy the equipment’s requirement to power and the safety and stability running of the electric energy system and the economic benefit, the priority mission of the electrical system is, start and stop the unit, adjust the load, switch between equipment and line, constant survey major equipment, quickly react to failure or unusual situation, etc. The above missions are completed by operation of major electrical equipment. The main electrical equipment in this plant as follow:1.1.1汽轮发电机发电机是根据电磁感应原理而工作的一种旋转电气设备,它将机械能转变成电能。
它与汽轮机直接耦合传动。
发电机旋转方向从汽轮机端看为顺时针方向。
Generator is one kind of rotate electrical equipment which follows the rule of electromagnetic induction, transferring mechanic energy into electric energy. t directly couples to the turbine and rotates. The direction of generator rotating is clockwise seen from the turbine end.型号power factor model QFW-7-2 6600V额定功率rated power7000kW功率因数power factor(COSφ)额定定子电压rated stator voltage6600V 额定定子电流rated statorcurrent765A额定转速rated rotation speed3000r/min极数number of polar2相数number ofphase3定子接法stator connectiontypeY柴油发电机柴油发电机平时处于备用状态,当发生全厂停电事故时,自动控制系统会自动隔离厂用电母线和事故保安段母线,同时发出信号命令柴油发电机启动,柴油发电机自带控制系统,可以在10-15s内自动完成柴油启动、调速、升压、合闸一系列的过程,供电给事故保安段母线,维持基本的设备运转,保障锅炉和汽机及其他辅助设备的安全停机。
It is usually in backup status. When the plant is under emergency shutdown, the auto control system will isolate the plant supply busbar and the security section, at the same time sends out signal to command the diesel generator to start, adjust speed, boost up pressure, shut valve and series of action, and supply power to security section, keep basic equipment running in10 to15 second, guaranteeing the safety shutdown of boiler and turbine and other auxiliary equipments.电动机电动机是根据电磁感应原理工作的一种旋转电气设备,它将电能转化为机械能,拖动电厂风机、泵类、压缩机等机械。
根据电厂工艺的要求,其中一次风机、二次风机、引风机、给水泵和凝结水泵等设备采用变频调速控制,其拖动电机也采用相应的变频电机。
Motor is a kind of rotating electric equipment which follows the rules of electromagnetic induction. It transfers electric energy to mechanical energy, driving fans, pumps, compressors and other machines in the plant. According to the technical requirement, primary fan, secondary fan, induced draft fan, water feed pump and condensing water pump adopt frequency control, their motors adopt converter motors in correspondence.高压电动机 High voltage motor 低压电动机Low voltage motor主变压器 Main transformer变压器是一种静止电器,它利用电磁感应原理,把一种电压、电流的交流电能变成为同频率的另一种电压、电流的交流电能。
Transformer is a static appliance. It follows the rules of electromagnetic induction, makes one kind of AC power into another kind with same frequency but different voltage and current.油浸式主变压器Oil-immersed main transformer厂用变压器 Plant transformer厂用变压器是专门给电厂自己供电用的。
Transformer factory is specialized for power plant their power supply.三相环氧树脂浇注干式变压器three-phase epoxy resin placing dry transformer型号Model SCB10-2000/额定容量Ratedcapacity2000KVA频率Frequency50Hz一次电压Primaryvoltage±2×%二次电压Secondaryvoltage相数Number ofphase3一次电流Primarycurrent 175A二次电流Secondarycurent冷却方式Cooling typeAF变压器保护设备Transformer protection device变压器保护装置是集保护、监视、控制、通信等多种功能于一体的电力自动化高新技术产品,是构成智能化开关柜的理想电器单元。
The transformer protection device is set protection, monitoring, control, communication and other functions in the integration of electric power automation high-tech products, are the ideal intelligent switchgear electrical unit.33 kV高压柜 33 kV high voltage cabinet开关柜本体The body of switch cabinet1型式Type2额定电压Rated voltage33 3最高运行电压Maximum running voltage38 4额定电流Rated current630 5相数Number of phases3 6额定频率Rated frequency50HZ 7额定动稳定电流Rated motion stabilized current808热稳定电流(有效值)Hot stabilized current (virtualvalue)9热稳定电流持续时间Continuing time of hot stabilizedcurrent4S10一分钟工频耐受电压(有效值)Voltage tolerance under 1minute working frequency(virtual value)主绝缘对地Main insulate towardground95断口间绝缘Insulate between cuts11011雷电冲击水平(全波、峰主绝缘对地Main insulate toward185值)Class of thunder strike (fullwave, peak)ground断口间绝缘Insulate between cuts21512冷却方式Way of cool down自冷Self cool downkV高压柜 kV high voltage cabinet按照本厂使用需要, kV配电系统可以装备KYN28A-12型中置移开式铠装金属封闭开关柜和XGN2-12固定式金属封闭式开关柜。
According to the demand of this plant, the kV power distribution system has KYN28A-12 type center withdrawing metal shielded closed switch cabinets and XGN2-12 fixed metal shielded closed switch cabinets.KYN28A-12 XGN2-12低压配电柜 Low voltage power distribution cabinet本厂主厂房低压配电室需配备MNS型低压抽屉式开关柜,对厂用电源、厂用备用电源、事故保安电源进行分配、切换、控制、监视和保护,是全厂厂用电配电中心。