四川美嘉龙生物科技有限公司天然气供气工程燃气工程安全评估方案编制单位:四川怡诚石油天然气工程有限公司日月年编制日期:2201327四川美嘉龙生物科技有限公司天然气供气工程安全评估方案人:制编人:审核现场负责人:项目负责人:编制单位:四川怡诚石油天然气工程有限公司日年月编制日期:22013 272四川怡诚石油天然气工程有限公司.目录.概况4................................................................................................................................................................ .. (1)1.1概述.............................................................................................................................................................41.2工程技术要求.............................................................................................................................................41.3编制依据.....................................................................................................................................................4、危害的识别及危害因素控制4 (2)2.1人身安全、设备危险.................................................................................................................................42.2其他危害(间接危害).............................................................................................................................62.3营地.............................................................................................................................................................63施工管理工作流程................................................................................................................................................73.1工作流程.....................................................................................................................................................73.2穿越管道施工应急流程图....................................................................................................................73.3应急小组的建立职责.................................................................................................................................83.4应急反应..................................................................................................................................................8、应急措施9............................................................................................................................................................. 44.1应急措施..................................................................................................................................................94.2应急救护措施..........................................................................................................................................94.3应急报警..................................................................................................................................................94.4现场急救..................................................................................................................................................9、应急预案105 .........................................................................................................................................................5.1“管沟跨塌”事件应急预案...................................................................................................................105.2“碰口烧伤”事件应急预案...................................................................................................................105.3“触电”事件应急预案...........................................................................................................................105.4“中毒”事件应急预案...........................................................................................................................105.5“交通”事件应急预案...........................................................................................................................105.6“火灾”事件应急预案...........................................................................................................................113四川怡诚石油天然气工程有限公司..概况1概述1.1本工程位于乐山市四川美嘉龙生物科技有限公司天然气供气工程。
为了保证施工顺利进行,确保施工安全,特制定此方案。
工程技术要求1.2a.该工程的埋地管道均采用20#输送流体无缝钢管。
b.钢管采用手工焊打底,材料为H08Mn2SiA焊丝,手工电弧焊方式填充,焊缝接头采用V形坡口,使用材料为E4315,Φ2.5焊条。
c.无缝钢管防腐采用三层PE普通级外防腐,补口采用交联聚乙烯热收缩套。
d.焊缝外观质量先进行100%外观质量检查,其质量不低于《现场设备、工业管道焊接工程施工及验收规范》GB50236-98II级质量要求;经外观检查合格后,所有穿越段环向焊缝都必须进行100%的射线探伤。
焊缝质量按照现行国家标准《无损检测金属管道熔化焊环向对接接头射线照相检测方法》GB/T12605-2008执行,达Ⅱ级质量为合格。
连头碰口工作应在建设方和现场负责人知道下进行,氮气置换也应符合相关规范规范。
e.该穿越段穿越时要注意交通安全f.编制依据1.3《四川美嘉龙生物科技有限公司天然气供气工程施工设计图纸》a.国家及行业现行有关施工技术规范。
b.本公司有关《压力管道安装质量保证体系》文件和拟投入的施工作业力量(包括人员和c.施工装备)。
、危害的识别及危害因素控制2人身安全、设备危险2.1序实施人制措施检查人控意外事故号施工中严格按施工安全措施碰口项目经理、A施工台班长碰口烧伤1施工队长、严格按施工程序施工B 和相关人员安全员施工中操作人员要穿戴好劳动保护服,每个碰火点要HSE C4四川怡诚石油天然气工程有限公司.5四川怡诚石油天然气工程有限公司.其他危害(间接危害)2.2营地2.36四川怡诚石油天然气工程有限公司.营地生活污水排水畅通,加盖,加强环境意识教育A监督员环境污染施工队长3生活垃圾应倒入驻地区指定的垃圾专放点HSE B生活用煤采购,使用优质、无污染的无烟煤C熬油时禁止擅离职守,无人看管A监督员火灾施工队长4 HSE厨房、宿舍禁止使用超过线路载荷的电器B施工管理工作流程3工作流程3.1无损检测;首先对穿越管道在开阔地进行组对焊接连接, 1. 100%RT穿越管段经无损检测合格后、防腐补口补伤均合格,电火花检测防腐层均无漏电;2.倍穿越管道单体强度试压合格。