Cable and Board Presence - Message Code: "x1Axx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
AC Cycle or SEL clear
Yes
Any
E1225
ESB 1.5VPwrGd
High
ESB 1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1226
PCIRsr1.5VPwrGd
High
PCI Riser 1.5 VV voltage regulator has failed.
Yes
Pre-Post
E1A12
PCIRsrMissing
High
One or all of the PCI risers is missing. This prevents system power on.
Failing device is reseated/replaced/repaired.
Yes
Yes
Pre-Post
E1A11
PCIRsrConfig
High
PCI risers are not configured correctly; some invalid configurations prevent system power on.
Failing device is reseated/replaced/repaired.
Yes
Any
E1311
RPM Fan Mod #A
Low
RPM of fan A in the # module is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1116
Temp Memory
High
Memory has exceeded allowable temperature and has been disabled to prevent damage to the components.
AC Cycle or SEL clear
Yes
AC Cycle or SEL clear
Yes
Any
E122C
CPU Power Fault
High
A voltage regulator failure was detected when the processor regulator(s) was enabled.
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Any
E122A
CPU VTTPwrGd
High
Processor VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E122B
0.9 V Over Voltage
High
0.9 V regulator voltage has exceeded the allowable voltage range.
Failing device is reseated/replaced/repaired.
Yes
Any
Temperature - Message Code: "x11xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1114
Temp Ambient
Med
Ambient temperature has a reached a point outside of the allowed range.
Temperature returns to allowable range.
Exists in SEL?
System Phase When Event Can Occur?
E1A10
PDBPwrCable
High
PDB power cable to the planar is missing or bad and system will not power on.
Failing device is reseated/replaced/repaired.
Yes
Any
E1A17
PwrCable FB
Low
Flex bay power cable is missing or bad.
Failing device is reseated/replaced/repaired.
Yes
Any
E1A18
PDBCtrl Cable
High
PDB control cable to the planar is missing or bad and system will not power on.
AC Cycle or SEL clear
Yes
Any
E1227
LinearPwrGd
High
Linear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry.
Yes
Any
E1311
RPM Fan Mod #B
Low
Same as above except for fan B of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
System Phase When Event Can Occur?
E1210
CMOSBatt
Low
CMOS battery is missing or the voltage is outside of the allowable range.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Yes
Any
W1228
ROMBBatt< 24 hr
Low
This is a predictive failure warning message telling the user that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer.
AC Cycle or SEL clear
Yes
Any
E1228
0.9VPwrGd
High
Memory VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1229
CPU # VCORE
High
Processor # VCORE voltage regulator has failed.
Failing device is reseated/replaced/repaired.
Yes
Any
E1A16
SAS Cable FB
Low
Flex bay SAS cable is missing or bad.
Failing device is reseated/replaced/repaired.
Any
Voltages - Message Code: "x12xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
E1311
RPM Fan Mod #C
Low
Same as above except for fan C of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
Fans - Message Code: "x13xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD