10kV绝缘导线技术资料
1、产品主要技术性能说明
产品简介
本产品适用于额定电压35kV及以下的架空电力线路。
架空绝缘电缆
的型号、名称及使用范围见表8-1。
电缆的机械性能和电性能符合国
家标准GBl4049《额定电压10kV、35kV架空绝缘电缆》和GBl2527
《额定电压1kV及以下架空绝缘电缆》。
其中钢芯铝绞线交联聚乙烯
绝缘架空电缆的缆芯结构参照国标GB/T1179《圆线同心绞架空导
线》,电缆的电性能和绝缘的机械物理性能符合国标GBl4049及
GBl2527。
架空电缆特性及工艺参数
【详细说明】
Aerial insulated cables with rated voltage up to and including 0.6/1KV
产品标准
本产品按GB12527-90《额定电压0.6/1KV及以下架空绝缘电缆》及IEC60502《额定电压1-30KV 挤包绝缘电力电缆及附件》等标准制造。
The product is manufactured according to the standards of GB 12527-90《Aerial insulated cables of rated voltages up to and including 1 KV》and IEC60502《Extruded solid dielectric power cables for rated voltages from 1KV to 30 KV》。
使用特性
额定电压Uo/U为0.6/1KV.
Rated voltage Uo/u:0.6/1KV.
电缆导体的长期允许工作不超过湿度:
聚氯乙烯、聚乙烯绝缘架空电缆:70℃;
交联聚乙烯绝缘架空电缆:90℃。
Max.permissible continuous temperature:
PVC、PE insulated aerial cables:70℃
XLPE insulated aerial cables:90℃.
短路时(最长持续时间不超过5秒)电缆导体的最高温度应不超过:
聚氯乙烯绝缘架空电缆:160℃;
聚乙烯绝缘架空电缆:130℃;
交联聚乙烯绝缘架空电缆:250℃。
Max.short-circuit temperature of the conductor shall not execeed:
PVC insulated aerial cabl es: 160℃;
PE insulated aerial cables: 130℃;
XLPE insulated aerial cables: 250℃.
电缆敷设时环境温度应不低于-20℃。
than 6 times the diameter of cables .
The installation ambient temperature should not below -20℃。
电缆的允许弯曲半径:
电缆外径(D)小于25mm时,应不小于电缆外径的4倍;
电缆外径(D)等于或大于25mm时,应不小于电缆外径的6倍。
The bending radius of cables are recommend as follows:
When the diameter of cables less than 25 mm : not less than 4 times the diameter of cables ; When the diameter of cables not less than 25 mm : not less
当电缆使用于交流系统时,电缆的额定电压至少应等于该系统的额定电压;当电缆使用地直流系统时,该系统的额定电压应不大于电缆额定电压的1.5倍。
When the cables use in alternating current system, rated voltage of cables should be at least equal the rated voltage of the system; When the cables use in direct current system,rated voltage should be not greater than 1.5 times of the rated voltage of the cables . 电缆的型号、名称
型号Type 名称 Designation 主要用途 Main
usefulness
JKV 铜芯聚氯乙烯绝缘架空电缆 Copper conductor PVC insulated
aerial cables 架空固定敷设、引户
线等
JKLV 铝芯聚氯乙烯绝缘架空电缆 Aluminum conductor PVC insulated
aerial cables
JKLHV 铝合金芯聚氯乙烯绝缘架空电缆 Aluminum alloy conductor PVC
insulated aerial cables
JKY 铜芯聚乙烯绝缘架空电缆 Copper conductor PE insulated
aerial cables
JKLY 铝芯聚乙烯绝缘架空电缆 Aluminum conductor PE insulated
aerial cables
JKLHY 铝合金芯聚乙烯绝缘架空电缆 Aluminum alloy conductor PE
insulated aerial cables
JKYJ 铜芯交联聚乙烯绝缘架空电缆 Copper conductor XLPE
insulated aerial cables
JKLYJ 铝芯交联聚乙烯绝缘架空电缆 Aluminum conductor XLPE
insulated aerial cables
JKLHYJ 铝合金芯交联聚乙烯绝缘架空电缆 Aluminum alloy conductor
XLPE insulated aerial cables
JKLGV 钢芯铝绞线芯聚氯乙烯绝缘架空电缆 ACSR conductor PVC
insulated aerial cables
JKLGY 钢芯铝绞线芯聚乙烯绝缘架空电缆 ACSR conductor PE
insulated aerial cables
JKLGYJ 钢芯铝绞线芯交联聚乙烯绝缘架空电缆 ACSR conductor XLPE
insulated aerial cables
电缆的规格
型号Type
芯数
Cores
Number
额定电压
Rated
Voltage kv
标称截面
mm2
JKV 、 JKLV 、 JKLHY 、 JKY 、 JKLY 、 JKLHY 、 JKYJ 、JKLYJ 、 JKLHYJ 、 JKLGV 、 JKLGY 、 JKLGYJ
1 0.6/1 10~240
2.4 10~240
JKLV 、 JKLY 、 JKLYJ 3+K*10~240 电缆结构图
电缆的结构和技术参数
注明:关于电缆的其他技术参数详见所提供的产品样本
4、产品工艺流程图
3、主要原材料供应厂家一览表
(2)主要生产设备
(3)检测设备
使用条件
表3-1 使用条件
表4-1 绝缘线技术参数响应表
4.2 技术差异表
投标人提供的产品技术规范应与技术规范书中规定的要求一致。
如有差异投标人应如实、认真地填写差异值;若无技术差异则视为满足本技术规范的要求,且在技术差异表中填写“无异差”。
表4-2 技术差异表
附录B 技术参数通用部分条款变更表
注本表是对技术规范“通用部分”的补充和修改,如有冲突,应以本表为准。