EMCVPLEX安装实施方案

VPLEX-LOCAL 的硬件配置信息此次安装的VPLEX-Local有单台台VPLEX组成, VPLEX的硬件配置如下:1) 1 个 Engine2) 2 个 Director ,每个 Engine 由两个 Director 组成3)8 个 8Gb 前端 FC端口,每个Director 包含一块前端FC卡,共 4 个 8Gb 的前端 FC端口,由于交换机端口限制,本次使用 4 个前端 FC端口(每个 Directo 上两个)。

4)8 个 8Gb 后端 FC端口,每个Director 包含一块后端FC卡,共 4 个 8Gb 的后端 FC端口。

本次使用4 个前端 FC 端口(每个Directo 上两个)5) 4 个可用的 8Gb 的 VPLEX-Local级联 FC端口,每个 Director 包含一块 VPLEX-Local级联 FC卡,共 4 个 8Gb 的级联 FC端口,但是只有两个可用VPLEX-LOCAL 的硬件介绍单台 VPLEX的硬件布局VPLEX 的 ENGINE 的硬件布局VPLEX-LOCAL 的级联端口连接VPLEX-LOCAL 拓扑结构VPLEX-LOCAL 的 FABRIC 拓扑图Host HostFabric Switch Fabric SwitchManagement serverEngine power supplyVNX VPLEX VNX VPLEX-LOCAL 后端存储系统的配置HOST_PRD HOST_BAKVPLEX_0550 VPLEX_0549VMAX_3358 VplexMetavolume ( >= 78GB, using144GB )Host data volumeVMAX_0251Vplex Meta volume backup( >=78GB, using 144GB ) Host data volume VPLEX logging volume ( >=10GB, using 72GB )Host data volumeMETA VOLUME 的配置请注意每台VNX必须使用两个RG,每个RG各提供两个80G LUN。

Mirror和 backup的meta volumeLUN 需分开RG 存放。

不推荐mirror和backup放在同一个RG里。

Cluster Meta Volume Storage RAID Group LUN ID RAID SizeVPLEX_01 Meta_Mirror_1 VNX5400 RG1 800 RAID10 80GBMeta_Bcakup_1 VNX5400 RG1 801 RAID10 80GB Meta_Mirror_2 VNX5400 RG0 800 RAID10 80GB Meta_Backup_2 VNX5400 RG0 801 RAID10 80GBLOGGING VOLUME 的配置Cluster Log Volume Storage RAID LUN ID RAID SizeGroupVPLEX_01 Loggin_Mirror_1 VNX5400 802 RAID10 10GB Mirror 2 VNX5400 802 RAID10 10GBVPLEX-LOCAL 安装配置流程VPLEX-LOCAL 安装配置详细步骤在 VPLEX-Local的安装配置过程中,有些命令在ManagerServer上运行,有些命令在VPLEX上运行,以下标志代表命令的运行场所:【MS_CLUSTER_1】 : VPLEX_01 的 Manager Server 的 shell 环境下运行【VPLEXCLI_CLUSTER_】1: VPLEX_01的 VPlex 的 CLI环境下运行,在 Manager Server 的 shell 环境下,运行“vplexcli ”命令进入该环境【MS_CLUSTER_2】 : VPLEX_02 的 Manager Server 的 shell 环境下运行【VPLEXCLI_CLUSTER_】2: VPLEX_02的 VPlex 的 CLI环境下运行,在 Manager Server 的shell 环境下,运行“ vplexcli ”命令进入该环境CLUSTER_1 的安装配置CLUSTER_1 的初始化配置1. 将配置用的笔记本电脑的网卡设置为通过 DHCP获取 IP2.配置用的笔记本电脑通过网线连接到VPLEX_01的 Manager Server 的 eth1 网口3.通过 putty.exe 或 SecureCRT软件登陆到 VPLEX_01的 ManagerServer 上, Host IP: 128.221.252.2 , Connect type : SSH,用户名: service ,密码: Mi@Dim7T4.设置 Manager Server 的主机名【M S_CLUSTER_1】 # sudo /opt/emc/VPlex/tools/ipconfig/changehostname.py -n VPLEX-015.重新登陆 Manager Server ,查看提示符或 /etc/HOSTNAME 文件内容,确认主机名更改成功【M S_CLUSTER_1】 # cat /etc/HOSTNAME6.运行 vplexcli 命令登陆到 VPLEX_01,用户名为 service ,密码为 Mi@Dim7T【M S_CLUSTER_1】 # vplexcli7. 配置 Manager Server 的管理公用IP 地址【V PLEXCLI_CLUSTER_】1 # management-server set-ip -i VPLEX_01_IP:VPLEX_NETMASK -g VPLEX_GATEWAY eth3【V PLEXCLI_CLUSTER_】1 # ll /management-server/ports/eth38.运行 exit 命令,退出 VPLEX_01到 Manager Server ,检查公用管理网络的连通性【V PLEXCLI_CLUSTER_】1 # exit【M S_CLUSTER_1】 # ping VPLEX_GATEWAY9.配置 NTP 时钟服务器,同步时间【 MS_CLUSTER_1】 # vi /etc/ntp.conf ; 设置外部 server 为 NTP_IP【M S_CLUSTER_1】 # sudo /etc/init.d/ntp restart【M S_CLUSTER_1】 # date10.运行 exit 命令,退出 VPLEX_01的 Manager Server【M S_CLUSTER_1】 # exit启动 CLUSTER_1 的 DIRECTOR,检查和确认版本信息11. 通过 putty.exe 或 SecureCRT软件登陆到 VPLEX_01的 Manager Server 上,用户名为service,密码为 Mi@Dim7T12.运行 vplexcli 命令登陆到 VPLEX_01,用户名为 service ,密码为Mi@Dim7T 【 MS_CLUSTER_1】 # vplexcli13. 启动 VPLEX的 Director ,确认显示的director 数量正确(2 个 director )【V PLEXCLI_CLUSTER_】1 # configuration connect-local-directors【V PLEXCLI_CLUSTER_】1 # ll /engines/**/directors14.检查 VPLEX及每个 Director 的版本,确认符合版本控制要求【V PLEXCLI_CLUSTER_】1 # version【V PLEXCLI_CLUSTER_】1 # exit检查硬件运行状态15.检查 VPLEX及每个 Director 的版本,确认符合版本控制要求【 MS_CLUSTER_1】VPlexPlatformHealthCheck确认检查结果符合下表:运行 EZ-SETUP 配置向导16.运行 EZ-Setup 配置向导,完成以下方面的配置:【M S_CLUSTER_1】 # vplexcli【V PLEXCLI_CLUSTER_】1 # configuration system-setup提示选择What would you like to configure? 21.Configure a VPLEX Local (single cluster).2.Configure a VPLEX Metro (synchronous, 2 clusters).3.Configure a VPLEX Geo (asynchronous,2 clusters). Select your configurationchoice. (1-3)What would you like to configure? 11. Configure the first or only cluster.2. Configure the second cluster of a VPLEX Metro implementation.Select your configuration choice. (1,2)Are you sure you want to configure the first or only cluster? (yes/no): yesWould you like to configure the login banner? (yes/no): no Would you like to configure an authentication service provider to authenticateVPLEX users? (yes/no) [no]: no Would you like to configure this cluster to send event notifications to EMC?(yes/no) [yes]: no Would you like to configure this cluster to send system reports to EMC?(yes/no) [yes]: no Would you like to configure the cluster to run the SNMP Agent Service? (yes/no) [no]: no How many years should the CA certificate remain valid before expiring? EMC recommends 5 years 5 (maximum is 5 years). [5]:How many years should the host certificate remain valid before expiring? EMC recommends 2 years 2(maximum is 2 years). [2]:Would you like to run the setup process now? (yes/no): yesPlease create a passphrase (at least 8 characters) for the Certificate Authority Key. Make a note of this guizhou_s fdxpassphrase as you will need it to configure a second cluster of a VPLEX Metro or Geo. Certificate Authoritypassphrase:Re-enter the passphrase for the Certificate Authority Key: guizhou_s fdxPlease create a passphrase (at least 8 characters) for the Local Host Certificate Key. Make a note of this guizhou_s fdxpassphrase as you will need it later. Host Certificate passphrase:Re-enter the passphrase for the Certificate Key: guizhou_sfdx配置 CLUSTER_1与后端存储系统之间的 ZONE17.获取 VPLEX_01端口的 WWN【 VPLEXCLI_CLUSTER_】1 # ll /engines/**/ports18. 登陆到SAN Switch,运行“ switchshow ”命令,检查VPLEX_01后端端口在SAN Switch 上的连接是否符合规划,否则根据规划进行调整19.登陆到 SAN Switch,创建与 Metadata Volume 和 Logging Volume 相关的 VPLEX_01后端端口与后端存储系统前端端口之间的zoneVPLEX注册到后端存储系统及磁盘分配VPLEX_01 的后端端口注册到VNXVPLEX_01的后端端口在VNX 上的注册配置建议如下:Host name: VPLEX_01Host IP: VPLEX_01_IPInitiator type: CLARiiON OpenFailover Mode: 4VNX 上创建STORAGE GROUPStorage Group: SG_ VPLEX_01Host: VPLEX_01_1LUN: 2个78GB的Metadata Volume(800、801)和一个10GB的LoggingVolume(802),以及其他数据 LUN识别后端存储系统的 METADATA VOLUME 和 LOGGING VOLUME20.识别后端存储系统和相应的磁盘设备【 VPLEXCLI_CLUSTER_】1 # configuration continue-system-setup创建 METADATA VOLUME21. 获取适合创建 Metadata Volume 的磁盘设备,比较 VPLEX的 VPD 名字与 VNX LUN 的VPD 名字,确认 VNX5400 的 LUN 800 的 VPD 名字和 VNX5400 的 LUN 800 的 VPD 名字【V PLEXCLI_CLUSTER_】1 # configuration show-meta-volume-candidates22.创建 Metadata Volume【V PLEXCLI_CLUSTER_】1 # meta-volume create -n VPLEX_01_META -d < VXN5700 的 LUN 800 的VPD 名字 >,< VNX5400 的 LUN 800 的 VPD 名字 >23. 查看 Metadata Volume 的状态,确认active 属性列显示为true【V PLEXCLI_CLUSTER_】1 # ll /clusters/cluster-1/system-volumes/ VPLEX_01_META24. 查看 cluster 的状态,确认cluster status 和 operational-status显示为 ok【V PLEXCLI_CLUSTER_】1 # cluster status设置 METADATA VOLUME 的备份时间25. 获取适合创建 Metadata Volume Backup 的磁盘设备,比较 VPLEX的 VPD 名字与 VNXLUN 的 VPD 名字,确认 VNX5400 的 LUN 801 的 VPD 名字和 VNX5400 的 LUN 801 的VPD 名字【 VPLEXCLI_CLUSTER_】1 # ll /clusters/cluster-1/storage-elements/storage-volumes26.选择 Metadata Volume 的备份设备为: VNX5400 的 LUN 801 的 VPD 名字 >,< VNX5400 的 LUN801 的VPD 名字 >。

相关主题