Pass / Fail: According to specification 4 hours storage at 0℃, and operating at 40℃. : Not Specified Test Equipment: TOPNOTCH OTC-2B-N Open Chamber. : Not Tested CHROMA Series AC Source / DC LoadA. INPUT CHARACTERIZATIONINPUT CURRENT/POWER/EFFICIENCY/POWER FACTORTest conditions:The unit is set at maximum load and the input voltage is varied from the minimum to themaximum value. Efficiency is computed and Power Factor is either computed or measured after10 minutes warm up at least.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadChroma Model # 6630 Power AnalyzerPass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25CVin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%) Vin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%)@40CVin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%)ACTIVE MODE EFFICIENCY & NO LOAD INPUT POWERTest conditions:The unit is set at no load and the rated input voltage for at least 15 minutes.The ambient temperature is set between 15 Deg C to 35 Deg CTest equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 65909KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadChroma Model # 6630 Power AnalyzerPass/Fail criteria:The unit test shall meet the specification requirements.ACOUSTIC NOISETest conditions:Measurements to determine the AC adapter sound pressure are made using a 1/2” low noise free-field microphone in a inner size with 45(W)×45(D)×65(H) cm^3 Anechoic chamber. Test equipment:Anechoic Chamber: Free-Field Acoustics Corp. Lower than 10dB(A) background noise.B & K Portable Pulse – Type 3560C, Microphone: 4190, Preamplifier: 2669LPass/Fail criteria:The AC Adapter shall produce no human perceivable audible noise (less then 25dB).The above diagram depicts the microphone of the frontal plane of the microphone to theAdapter and the height of the centerline of the microphone to the Adapter.Acoustic Noise Test Set-UpINRUSH CURRENTTest condition:For cold start test at room ambient, the adapter should be off for at least one hour at the test temperature to ensure it is at a uniform temperature before the test is started. Turn on theUUTat 90 degrees at positive cycle or 270 degrees at negative cycle. Between each test, the UUTshall be cooled down for at least 3 minutes and the Bulk Cap’s Energy is discharged.For hot start test at max. Operating ambient, the adapter should be on and running for at least one hour at the test temperature to ensure it is at a uniform temperature before the test isRepetitive ON/OFF (1Sec. ON/1Sec. OFF for 10 times) cycling of the UUT and turn on at 90degrees at positive cycle or 270 degrees at negative cycle. Between each test, the Bulk Cap’sEnergy shall be discharged.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix AM503 Current Probe AmplifierTektronix A6303 Current ProbeTektronix TDS-5054 OscilloscopePass/Fail criteria:The inrush current shall meet the specification requirements.AC line inrush current shall not damage any components, nor cause the AC line fuse to blow,under any DC load conditions, any ambient temperature, and with any ac line input voltageand frequency.Test result: PASSExtended Name = Cold start 25 deg. ambient; after Extended Name = Cold start 25 deg. ambient; after1 hour in off stage Vin=90Vac Inrush Current=57.6A.1).Vin 4).Iin 1 hour in off stage Vin=264Vac Inrush Current=138.0A. 1).Vin 4).IinExtended Name = Hot start 25 deg. ambient; Repetitive on/off cycle 10 times. Vin=90Vac Inrush Current=56.4A. 1).Vin 4).Iin Extended Name = Hot start 25 deg. ambient; Repetitive on/off cycle 10 times. Vin=264Vac Inrush Current=138.0A. 1).Vin 4).IinLINE CYCLE DROPOUTTest conditions:The unit is subjected to a dropout of the AC line voltage from 100Vac/50Hz to zero volt for duration which equal to 7mS repeated 10 times with a period of 1 second. The unit is fully loaded. Dropout shall occur at any input phase angle.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopeTektronix P5100 ProbePass/Fail criteria:The unit test need not maintain within regulation but shall not latch off.Test result: PASSExtended Name = Dropout; 100Vac/50Hz (0deg) Dropout 10 ms at Max. Load1) Vin 2) VoExtended Name = Dropout; 100Vac/50Hz(90 deg) Dropout 10 ms at Max. Load1) Vin 2) VoExtended Name = Dropout; 100Vac/50Hz(270 deg) Dropout 10 ms at Max. Load1) Vin 2) VoBROWNOUT & BROWNOUT RECOVERYTest conditions:1. The input voltage decreases from 90Vac/50Hz down to zero in 30 minutes.2. The input voltage increases from 0Vac up to 90Vac/50Hz in 30 minutes.Test equipment:CHROMA 6530 AC SOURCECHROMA 630XX DC LOADPass/Fail criteria:1. The input voltage below the minimum specifies shall not cause damage to the power supplyunit (due to over-heating or otherwise).2. The PSU shall recover after an AC power reset.Test result: PASS@25CTOTAL HARMONIC DISTORTIONTest conditions:The power line is distorted (flat-topped) with a total harmonic distortion of up to10% (100Vac @ 50 Hz with 10 % THD = 90 Vrms).Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 65909KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopeTektronix P5100 ProbePass/Fail criteria:The unit test shall meet the specification requirements.Test result:PASSExtended Name = Start up operation.100Vac/50Hz @ Full Load(1) Vin (2) VoutExtended Name = Continuous operation.100Vac/50Hz @ Full Load(1) Vin (2) VoutLINE VOLTAGE SURGETest conditions:While the unit is operating with maximum continuous load, the line voltage is switched to the surge voltage as indicated below:• 220Vac to 286Vac for 1sec, and back to 220Vac at 50Hz, repeated 10 times with 10seconds interval.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopeTektronix P5100 ProbePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSExtended Name = Line Surge 220Vac to 286Vac forsec. Full Load.1) Vin 2) VoLINE VOLTAGE SAGTest conditions:While the unit is operating with maximum continuous load, the line voltage is switched tothe sag voltage as indicated below:• 100Vac to 80Vac for sec., and back to 100Vac at 50Hz, repeated 10 times with 10 seconds interval.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopeTektronix P5100 ProbePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSExtended Name = Line Sag 100Vac to 80Vac for500mS.1) Vin 2) VoVOLTAGE DIP IMMUNITYTest conditions:While the unit is operating with maximum continuous load, the 100Vac/50Hz and 240Vac/50Hz line voltage is switched to the dip voltage as indicated below:• 30%, 60%, 100% dip voltage for:, 1cycle, 5cycle, 10cycle, 25cycle, 50cycle, 250cycle durationsTest equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopePass/Fail criteria:The unit test shall meet the specification requirements.Note: *1 Output within spec & no damage; *2 Self shutdown & no damageHARMONIC CURRENTS & EN61000-3-2 PRE-COMPLIANCETest condition:The harmonic components are compared with the limits set for Class D equipment. The input voltage is set at indicated values and the harmonic current values are recorded and compared to the EN61000-3-2 requirements.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopePass/Fail criteria:The harmonic current values shall meet the EN61000-3-2 requirements.B. OUTPUT CHARACTERIZATIONLOAD, LINE/CROSS REGULATIONTest condition:Test is repeated from different input voltages. The output is at minimum load then at maximum. Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadPass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25CVin(V)Fre.(Hz)Power(W)Load(A)Vout(V)------------------@0CVin(V)Fre.(Hz)Power(W)Load(A)Vout(V)------------------@40CPEAK LOAD.Test conditions:The output regulation shall be kept for a period of 5Sec at 6.32A peak load from90W. Test equipment:Tektronix TCP-202 Current ProbeTektronix TDS-5054 OscilloscopePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25CVin (Vac)Fin (Hz)InitialLoad(A)SurgeLoad(A)DurationTime(mS)Vout MaxSpec.(V)Vout MinSpec.(V)VoutMax.(V)VoutMin.(V)ResultPASSPASSExtended Name = 90Vac @Full loadthen peak to 6.32A2). Vout 3). IoutExtended Name = 264Vac @Full loadthen peak to 6.32A2). Vout 3). Iout@0CVin (Vac)Fin (Hz)InitialLoad(A)SurgeLoad(A)DurationTime(mS)Vout MaxSpec.(V)Vout MinSpec.(V)VoutMax.(V)VoutMin.(V)ResultPASSPASSExtended Name = 90Vac @Full loadthen peak to 6.32A2). Vout 3). IoutExtended Name = 264Vac @Full loadthen peak to 6.32A2). Vout 3). IoutVin (Vac)Fin (Hz)InitialLoad(A)SurgeLoad(A)DurationTime(mS)Vout MaxSpec.(V)Vout MinSpec.(V)VoutMax.(V)VoutMin.(V)ResultPASSPASSExtended Name = 90Vac @Full loadthen peak to 6.32A2). Vout 3). IoutExtended Name = 264Vac @Full loadthen peak to 6.32A2). Vout 3). IoutRIPPLE AND NOISE conditions:Ripple voltage and noise are measured at the pins of the mating connector of which each output is decoupled by a high frequency and tantalum capacitor. Bandwidth is set at 20MHz.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TCP202 Current ProbeTektronix P5100 ProbeTektronix TDS-5054 OscilloscopePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25CInput(Vac)Frequency Total Power (W)Load (A)PARD (mV) 904726463904726463Extended Name = 90V/ 47Hz 0A 1) Vpk-pk Extended Name = 264V/ 63Hz 0A 1) Vpk-pkExtended Name = 90V/47Hz Full Load 1) Vpk-pk Extended Name = 264V/ 63Hz Full Load 1) Vpk-pkInput(Vac)Frequency Total Power (W)Load (A)PARD (mV) 904726463904726463Extended Name = 90V/ 47Hz 0A 1) Vpk-pk Extended Name = 264V/ 63Hz 0A 1) Vpk-pkExtended Name = 90V/47Hz Full Load 1) Vpk-pk Extended Name = 264V/ 63Hz Full Load 1) Vpk-pkInput(Vac)Frequency Total Power (W)Load (A)PARD (mV) 904726463904726463Extended Name = 90V/ 47Hz 0A 1) Vpk-pk Extended Name = 264V/ 63Hz 0A 1) Vpk-pkExtended Name = 90V/47Hz Full Load 1) Vpk-pk Extended Name = 264V/ 63Hz Full Load 1) Vpk-pkDYNAMIC LOAD RESPONSETest conditions:The dynamic load response changes at a rate and load step and frequency change are basis specification defined.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadChroma Model # 6630 Power AnalyzerTektronix TDS-5054 OscilloscopeTektronix P5100 ProbeTektronix TCP202 Current ProbePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25CDynamic load condition Vspec-max Vspec-min Vreading-max Vreading-min Test result90Vac/ 47Hz; 0%load ~50%load;100Hz; 1.0A/uS. PASS264Vac/ 63Hz; 0%load ~50%load;100Hz;1.0A/uS. PASS90Vac/ 47Hz; 50%load ~100%load;100Hz; 1.0A/uS. PASS264Vac/ 63Hz; 50%load~100%load;100Hz;1.0A/uS.PASSExtended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) Io@0CDynamic load condition Vspec-max Vspec-min Vreading-max Vreading-min Test result90Vac/ 47Hz; 0%load ~50%load;100Hz; 1.0A/uS. PASS264Vac/ 63Hz; 0%load ~50%load;100Hz;1.0A/uS. PASS90Vac/ 47Hz; 50%load ~100%load;100Hz; 1.0A/uS. PASS264Vac/ 63Hz; 50%load~100%load;100Hz;1.0A/uS.PASSExtended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) Io@40CDynamic load condition Vspec-max Vspec-min Vreading-max Vreading-min Test result90Vac/ 47Hz; 0%load ~50%load;100Hz; 1.0A/uS. PASS264Vac/ 63Hz; 0%load ~50%load;100Hz;1.0A/uS. PASS90Vac/ 47Hz; 50%load ~100%load;100Hz; 1.0A/uS. PASS264Vac/ 63Hz; 50%load~100%load;100Hz; PASS1.0A/uS.Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) IoOUTPUT OVER/UNDER SHOOTTest conditions:The power adapter unit was tested either at Turn On/Off or from Full Load to No Load. Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSConditionOutputOvershootMax.(%)OutputOvershootReading.(%)OutputVoltageMax.(V)OutputVoltageReading.(V)Test ResultTurn on overshoot;Vin=90Vac; No Load*PASS Turn on overshoot;Vin=90Vac; Full Load*PASS Turn on overshoot;Vin=264Vac; No Load*PASS Turn on overshoot;Vin=264Vac; Full Load*PASSExtended Name = Turn on overshoot;Vin=90Vac; No Load2) VoExtended Name = Turn on overshoot; Vin=90Vac;Full Load2) VoExtended Name = Turn on overshoot; Vin=264Vac; No Load2) Vo Extended Name = Turn on overshoot; Vin=264Vac; Full Load2) VoTIMING REQUIREMENTSTest conditions:The following timings are measured:• AC Turn-on delay: Output voltage shall reach its nominal setting from AC power on.• AC Hold-up time: The output voltage shall remain its normal setting from AC power off.• DC output rise time: The output voltage rise time measured from 10% to 90%.• DC output fall time: The output voltage fall time measured from 90% to 10%.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopeTektronix P5100 ProbePass/Fail criteria:All parameters shall be within specification.Test result: PASSTiming Condition Vin(Vac)Freq(Hz)SpecMax.(mS)SpecMin.(mS)Reading(mS)ResultTurn on 90Vac; Full Load **PASS Turn on 115Vac; Full Load *PASS Turn on 230Vac; Full Load *PASS Turn on 264Vac; Full Load **PASSExtended Name = Turn on 90Vac; Full Load 1) Vin 2) Vo Extended Name = Turn on 115Vac; Full Load 1) Vin 2) VoExtended Name = Turn on 230Vac; Full Load 1) Vin 2) Vo Extended Name = Turn on 264Vac; Full Load 1) Vin 2) VoTiming Condition Vin(Vac)Freq(Hz)SpecMax.(mS)SpecMin.(mS)Reading(mS)ResultHold up 90Vac; Full Load **PASS Hold up 115Vac; Full Load *PASS Hold up 230Vac; Full Load*PASS Hold up 264Vac; Full Load**PASSExtended Name = Hold up 90Vac; Full Load (1) Vin (2). Vout Extended Name = Hold up 115Vac; Full Load (1) Vin (2). VoutExtended Name = Hold up 230Vac; Full Load(1) Vin (2). VoutExtended Name = Hold up 264Vac; Full Load(1) Vin (2). VoutTiming Condition Vin(Vac)Freq(Hz)Loading(A/Ohm)SpecMax.(mS)SpecMin.(mS)Reading(mS)Result Rise Time; Vin=115V;No Load (10% ~ 90%)*PASS Rise Time; Vin=230V;No Load (10% ~ 90%) *PASS Rise Time; Vin=115V;Full Load (10% ~ 90%) *PASS Rise Time; Vin=230V;Full Load (10% ~ 90%) *PASSExtended Name = Rise Time; Vin=115V; No Load(10% ~ 90%)(2). VoutExtended Name = Rise Time; Vin=230V; No Load(10% ~ 90%)(2). VoutExtended Name = Rise Time; Vin=115V; Full Load(10% ~ 90%)(2). VoutExtended Name = Rise Time; Vin=230V; Full Load(10% ~ 90%)(2). VoutTiming Condition Vin(Vac)Freq(Hz)Loading(A)SpecMax.(mS)SpecMin.(mS)Reading (mS)Result Fall Time; Vin=115V; FullLoad (90% ~ 10%) **PASS Fall Time; Vin=230V; FullLoad (90% ~ 10%) **PASSExtended Name = Fall Time; Vin=115V; Full Load(90% ~ 10%)(2).VoutExtended Name = Fall Time; Vin=230V; Full Load(90% ~ 10%)(2).VoutLOOP GAINTest conditions:The loop gain test set at maximum / minimum load and the input voltage set to high / low line.Measurements feedback loop stability.Test equipment:Analog Network Analyzer AP200Pass/Fail criteria:Check compare Phase Margin shall be greater then 45 degTest result: PASSTest Item:Input: 90V/47HzOutput: 19V@1.32ATest Result:Gain = 0 dB,Phase Margin = deg.Phase = 0 deg,Gain Margin = dB.Test Item:Input: 265V/63HzOutput: 19V@1.32ATest Result:Gain = 0 dB,Phase Margin = .Phase = 0 deg,Gain Margin = .C. PROTECTIONSHORT CIRCUIT PROTECTIONTest conditions:A short circuit is defined as less than resistance between the output terminals.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 Oscilloscope Tektronix TCP202 Current Prob ePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSAC TURN ON THEN OUTPUT SHORTCriteriaVin (Vac) Freq (Hz) Loading (A) Iin_rms (A) Pin (W) Vrecovery max.(V) Vrecovery min.(V) Vrecovery(V) Test Result No Damage90 47 PASS 90 47PASS 264 63 PASS 264 63PASSExtended Name = 90Vac; No Load (2)Vo (3)IoExtended Name = 90Vac; Full Load (2)Vo (3)IoExtended Name = 264Vac; No Load (2)Vo (3)Io Extended Name = 264Vac; Full Load (2)Vo (3)Io@0CAC TURN ON THEN OUTPUT SHORTCriteriaVin (Vac) Freq (Hz) Loading (A) Iin_rms (A) Pin (W) Vrecovery max.(V) Vrecovery min.(V) Vrecovery(V) Test Result No Damage90 47 PASS 90 47PASS 264 63 PASS 264 63PASSExtended Name = 90Vac; No Load (2)Vo (3)IoExtended Name = 90Vac; Full Load (2)Vo (3)IoExtended Name = 264Vac; No Load (2)Vo (3)Io Extended Name = 264Vac; Full Load (2)Vo (3)Io@40CAC TURN ON THEN OUTPUT SHORTCriteriaVin (Vac) Freq (Hz) Loading (A) Iin_rms (A) Pin (W) Vrecovery max.(V) Vrecovery min.(V) Vrecovery(V) Test Result No Damage90 47 PASS 90 47PASS 264 63 PASS 264 63PASSExtended Name = 90Vac; No Load (2)Vo (3)IoExtended Name = 90Vac; Full Load (2)Vo (3)IoExtended Name = 264Vac; No Load (2)Vo (3)Io Extended Name = 264Vac; Full Load (2)Vo (3)IoOVER CURRENT PROTECTIONTest conditions:The load is increased to an estimated over current value in several steps. The test is repeated at different input voltages.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TCP202 Current ProbePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25CVin(Vac)Freq(Hz)OCP Max.(A)OCP Min.(A)OCP Reading(A)Result90.47.*PASS11560.*PASS 23050*PASS 264.63.*PASS@0CVin(Vac)Freq(Hz)OCP Max.(A)OCP Min.(A)OCP Reading(A)Result 9047*PASS 11560*PASS 23050*PASS 26463*PASS@40CVin(Vac)Freq(Hz)OCP Max.(A)OCP Min.(A)OCP Reading(A)Result90.47.*PASS11560.*PASS 23050*PASS 264.63.*PASSOVER VOLTAGE PROTECTIONTest conditions:Fooling the feedback loops of the output voltages performs it. Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSMethod Vin (Vac)Freq (Hz)Loading (A)OVPMax.(V)OVP Min.(V)OVPReading(V)ResultAC Turn Onthen OVP*PASS*PASS*PASS*PASSExtended Name = 90Vac; No Load; OVP After TurnOn(2).VoutExtended Name = 264Vac; No Load; OVP After TurnOn(2).VoutExtended Name = 90Vac; Full Load; OVP After Turn On(2).Vout Extended Name = 264Vac; Full Load; OVP After Turn On(2).VoutD. EMC/SAFETY/ENVIRONMENTALDielectric withstand voltage (Hi-Pot)Test conditions:Test equipment:7430 WITHSTANDING VOLTAGE TESTER (EXTECH) Pass/Fail criteria:Leakage CurrentTest conditions:Test equipment:SIMPSON 228 LEAKAGE CURRENT METERTK-2010 AC SOURCEPass/Fail criteria:Insulation Resistance (IR)Test conditions:Test equipment:7430 WITHSTANDING VOLTAGE TESTER (EXTECH) Pass/Fail criteria:Electromagnetic Discharge (ESD)Test conditions:Input Voltage: 110Vac/220Vac Output Load: Maximum Load (Dummy Load) Test equipment:NOISEKEN ESS-2000 (ESD TEST SYSTEM)Pass/Fail criteria:The Electromagnetic Discharge (ESD) shall meet the specification requirements.After test, the adapter shall meet the specification requirements.Please refer to tabled below.Electromagnetic Discharge (ESD) Test ResultElectromagnetic Fast Transient And Burst (EFT)Test conditions:Input Voltage: 110Vac/220Vac Output Load: Maximum Load (Dummy Load)Test equipment:EM TEST :UCS 500-M6Pass/Fail criteria:The Electromagnetic Fast Transient And Burst (EFT) shall meet the specification requirements.After test, the adapter meets specification requirements.Please refer to tabled below.Electromagnetic Fast Transient And Burst (EFT) Test ResultNote: Prior to reaching this final level the testing was incrementally in 500v increments.4.6 AC Surge Immunity (PLD_BI Wave)Test conditions:Input Voltage: 110Vac/220Vac Output Load: Maximum Load (Dummy Load) Test equipment:EM TEST:UCS 500-M6Pass/Fail criteria:The AC Surge Immunity (PLD_BI Wave) shall meet the specification requirements.After test, the adapter meets specification requirements.Please refer to tabled below.。