当前位置:文档之家› 摩擦焊接磁粉探伤报告

摩擦焊接磁粉探伤报告

摩擦焊接磁粉探伤报告
Magnetic Particle Inspection
规格:ф127钻杆
Spec: ф127 drill pipes
探伤根数:125 支(见JZ/QP-803-11磁粉探伤检验记录)
Qty: 125 joints ( with reference to JZ/QP-803-11 magnetic particle test records )
探伤仪型号:CDX-3。

Test equipment type: CDX-3
磁化方法:连续法电磁轭局部磁化。

Method: Continuation method, Electromagnetic yoke local magnetization.
磁化电流值(周向电流):10.2A
Magnetization current value (circumferential current): 10.2A
磁化灵敏度:15/100、30/100标准试片能清晰显示。

Magnetization sensitivity: 15/100, 30/100 standard test blocks can present clearly.
磁化时间:1-3秒断续加磁。

Magnetization time: 1s-3s interrupt remagnetize.
磁悬液浓度:1.3%~3%。

Concentration of magnetic suspending liquid: 1.3%-3%
提升力:>4.5kg
Lift:>4.5kg
验收标准:焊区整个外表面进行萤光磁粉探伤,检验是否有横向缺陷,横向缺陷经打磨后仍然无法完全去除,视为不合格品,
当横向缺陷经打磨以完全去除并光滑过渡,且打磨后尺寸符合图纸要求, 视为合格品。

Acceptance criteria:
To do the fluorescent magnetic particles test for the surface of welding zone and check whether there are horizontal cracks. If there are cracks and the cracks cannot be removed after grinding, these products will be rejected. If the cracks can be removed completely and transit smoothly after grinding, also the grinding size is according to order drawing strictly. These products are accepted.
人员资质:中国机械工程师学会无损检测学会MTⅡ资质。

视力正常。

Qualification of personnel: Grade 2 Certificate of Magnetic particle Testing(MT),
Nondestructive Testing Society(NTS), Chinese Mechanical Engineering Society (CMES). Good eyesights.
结论:经检测,该批钻具无损检测符合技术要求。

Conclusion: they are accepted after testing.
报告人:胡永生日期:2011-12-26
Inspector: Hu yongsheng. Date:2011-12-26。