ELECTRICAL TEST REPORT (ADAPTER)Item Test Specification Result Page #RemarksA.INPUT CHARACTERIZATION1.1Input Current/Power/Efficiency/Power Factor Eff%>84%;Iin<1.5A PASS31.2No Load Input Power&Active Mode EfficiencyNo load(Pin<0.5W);0.5W load(Pin<1.0W);1.0W load(Pin<1.7W);1.5W load(Pin<2.4W);11.6W load(Pin<14W)18.7W load(Pin<22W)Average efficiency>87%PASS41.3Acoustic Noise<25dB(A)PASS6 1.4Inrush Current No damaged(Cold Start)PASS7 1.5Line Cycle Dropout No latch off PASS9 1.6Brownout&BO Recovery No damaged PASS11 1.7Total Harmonic Distortion To start up and no damage PASS12 1.8Line Voltage Surge No damaged PASS13 1.9Line Voltage Sag No damaged PASS14 1.10AC Voltage Dip Immunity No latch off PASS151.11Harmonic Current EN61000-3-2class D PASS16B.OUTPUT CHARACTERIZATION2.1Load,Line Cross Regulation18.55Vdc~19.95Vdc PASS18 2.2Peak Load 6.16Asurge load for2mSec;Vo>17Vdc PASS19 2.3Ripple and Noise<380mVp-p PASS20 2.4Dynamic Loading Response18.55Vdc~19.95Vdc PASS22 2.5Output Over/Under Shoot<10%PASS242.6Turn On Delay/Hold up/DC Rise/Fall Time Power-on time<2Sec;Hold up time>5mS;Rise time<100mSPASS262.7Loop Gain>45deg.PASS30C.PROTECTION3.1Short circuit Protection No damage PASS313.2Over Current Protection>5.7A PASS333.3Over Voltage Protection Vmax:27V PASS34D.EMC/SAFETY/ENVIRONMENTAL4.1Electric Strength(Hi-Pot)<10mA PASS364.2Leakage Current<50uA@100Vac;<100uA@240Vac.PASS374.3Insulation Resistance(IR)>20MΩPASS384.4Electromagnetic Discharge(ESD)IEC61000-4-2PASS394.5Electromagnetic Fast Transient And Burst(EFT)IEC61000-4-4PASS414.6AC Surge Immunity(PLD_BI Wave)EN61000-4-5PASS434.7Electromagnetic Compatibility Under-6dB PASS45Pass / Fail: According to specification 4 hours storage at 0℃, and operating at 40℃N.S. : Not Specified Test Equipment: TOPNOTCH OTC-2B-N Open Chamber N.T. : Not Tested CHROMA Series AC Source / DC LoadPrepared Checked(TE)Checked(EE)ApprovedA. INPUT CHARACTERIZATION1.1 INPUT CURRENT/POWER/EFFICIENCY/POWER FACTORTest conditions:The unit is set at maximum load and the input voltage is varied from the minimum to themaximum value. Efficiency is computed and Power Factor is either computed or measured after10 minutes warm up at least.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadChroma Model # 6630 Power AnalyzerPass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25︒CVin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%) 90.00047.000 1.283103.90018.79088.85315.0470.89985.518 100.00050.000 1.128102.70018.78888.87713.8230.90886.540 115.00050.0000.965101.60018.80288.94812.6520.91387.547 120.00050.0000.924101.50018.78088.80612.6940.91387.494 130.00050.0000.851101.20018.78088.84112.3590.91287.788 140.00050.0000.790100.90018.78888.87712.0230.91088.084 150.00050.0000.738100.80018.79088.88811.9120.90788.183 160.00060.0000.695100.70018.80288.94811.7520.90388.329 170.00060.0000.655100.40018.79888.92411.4760.89988.570 180.00060.0000.620100.50018.79288.90011.6000.89788.458 190.00060.0000.589100.30018.78588.86511.4350.89388.599 200.00060.0000.563100.40018.78888.84111.5590.88888.487 210.00060.0000.539100.50018.78588.83011.6700.88488.388 220.00060.0000.517100.50018.78888.87711.6230.87988.434 230.00060.0000.498100.70018.79288.90011.8000.87588.282 240.00060.0000.481100.80018.79588.87711.9230.87088.171 250.00060.0000.465100.80018.80588.92411.8760.86588.218 264.00063.0000.447101.00018.79088.85312.1470.85387.973@0︒CVin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%) 90.00047.000 1.279103.60018.87089.23214.3680.89986.131 100.00050.000 1.127102.30018.86889.25513.0450.90787.248 115.00050.0000.967101.50018.87589.25512.2450.91187.936 120.00050.0000.926101.30018.86889.22012.0800.90988.075 130.00050.0000.852101.20018.88089.27911.9210.90988.220 140.00050.0000.789100.70018.86289.19611.5040.90988.576 150.00050.0000.739100.50018.88289.29111.2090.90588.846160.00060.0000.693100.40018.87089.23211.1680.90288.876 170.00060.0000.654100.20018.86889.25510.9450.89989.077 180.00060.0000.619100.10018.86889.22010.8800.89689.131 190.00060.0000.588100.10018.86889.22010.8800.89389.131 200.00060.0000.561100.20018.87289.24310.9570.88989.065 210.00060.0000.537100.20018.88089.27910.9210.88589.101 220.00060.0000.516100.30018.88289.29111.0090.88089.024 230.00060.0000.496100.20018.88589.30210.8980.87589.124 240.00060.0000.479100.30018.88589.30210.9980.87089.035 250.00060.0000.463100.40018.87889.26711.1330.86488.911 264.00063.0000.444100.40018.87589.25511.1450.85388.900@40 CVin(Vac)Freq(Hz)Iin(A)Pin(W)Vout(V)Pout(W)Pd(W)PF Eff(%) 90.00047.000 1.276103.60018.86589.17214.4280.90186.074 100.00050.000 1.125102.30018.86089.14913.1510.90787.145 115.00050.0000.963101.20018.86889.18412.0160.91188.127 120.00050.0000.922101.10018.87289.20811.8920.91288.237 130.00050.0000.849100.80018.88089.24311.5570.91088.535 140.00050.0000.787100.50018.88289.25511.2450.90988.811 150.00050.0000.735100.40018.87089.19611.2040.90788.841 160.00060.0000.692100.20018.86289.16111.0390.90388.983 170.00060.0000.652100.00018.86289.16110.8390.89989.161 180.00060.0000.618100.10018.86889.18410.9160.89689.095 190.00060.0000.58799.80018.87589.22010.5800.89389.399 200.00060.0000.56099.90018.88589.26710.6330.88989.356 210.00060.0000.536100.10018.88589.26710.8330.88589.178 220.00060.0000.51599.90018.88289.25510.6450.88089.345 230.00060.0000.495100.10018.87889.23210.8680.87589.142 240.00060.0000.477100.10018.87089.19610.9040.87089.107 250.00060.0000.462100.20018.86589.17211.0280.86488.995 264.00063.0000.444100.40018.87289.20811.1920.85488.8531.2 ACTIVE MODE EFFICIENCY & NO LOAD INPUT POWERTest conditions:The unit is set at no load and the rated input voltage for at least 15 minutes. The ambient temperature is set between 15 Deg C to 35 Deg C Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 65909KVA Low Impedance AC Source Chroma Model # 630X0 DC LoadChroma Model # 6630 Power Analyzer Pass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSNo Load Power Consumption: (Pin<0.5W)InputVoltage(Vac)Load(W)Iin rms(A)PowerFactor Pin(W)Vo (Vdc)1150.000.0500.0100.28119.3472300.000.0840.0160.31019.3470.5W Load Power Consumption: (Pin<1.0W)Input Voltage(Vac)Load(W)Iin rms(A)PowerFactorPin(W)Vo (Vdc)1150.50.0510.0730.43219.3452300.50.0840.0290.59019.3451.0W Load Power Consumption: (Pin<1.7W)Input Voltage(Vac)Load(W)Iin rms(A)PowerFactorPin(W)Vo (Vdc)115 1.00.0530.177 1.07419.343230 1.00.0850.063 1.24019.3431.5W Load Power Consumption: (Pin<2.4W)Input Voltage(Vac)Load(W)Iin rms(A)PowerFactorPin(W)Vo (Vdc)115 1.500.0550.273 1.72319.337230 1.500.0860.096 1.90019.33711.6W Load Power Consumption: (Pin<14W)Input Voltage(Vac)Load(W)Iin rms(A)PowerFactorPin(W)Vo (Vdc)11511.60.1410.80613.13019.28523011.60.1090.52613.17019.27018.7W Load Power Consumption: (Pin<22W)Input Voltage(Vac)Load(W)Iin rms(A)PowerFactorPin(W)Vo (Vdc)11518.70.2100.86320.96019.23723018.70.1360.68221.42019.237Active Mode Efficiency:Vin (Vac)Fin (Hz)Iin (A)Pin (W)Iout (A)Vout (V)Pout (W)Pd(W)P.F Eff(%)THD(%)Average EFF(%)Result 115.060.00.963101.404.73118.7888.8612.540.9187.6380.10115.060.00.72475.90 3.54718.9367.158.750.9188.4650.10115.060.00.48450.30 2.36419.0745.09 5.210.9089.6510.11115.060.00.25125.35 1.18119.2122.69 2.660.8889.5260.12115.060.00.0500.170.00219.340.040.130.0321.7140.1288.820PASS 230.050.00.495100.604.73118.7988.8911.710.8888.3580.14230.050.00.37575.50 3.54718.9367.178.330.8788.9690.15230.050.00.26050.60 2.36419.0845.11 5.490.8489.1430.15230.050.00.15225.59 1.18319.2122.73 2.860.7388.8150.91230.050.00.0840.260.00419.340.070.190.0127.8940.1588.821PASS1.3 ACOUSTIC NOISETest conditions:Measurements to determine the AC adapter sound pressure are made using a 1/2” low noise free-field microphone in a inner size with 45(W)×45(D)×65(H) cm^3 Anechoic chamber. Test equipment:Anechoic Chamber: Free-Field Acoustics Corp. Lower than 10dB(A) background noise.B & K Portable Pulse – Type 3560C, Microphone: 4190, Preamplifier: 2669LPass/Fail criteria:The AC Adapter shall produce no human perceivable audible noise (less then 25dB).Test result: PASSBack Ground 5.86dB (A)Specification No human perceivable audible noise(20 ~ 20KHz)Input Voltage / Reading (dB)Output Load(A)115Vac230Vac0 A21.616.91.58A18.621.0Max23.422.8The above diagram depicts the microphone of the frontal plane of the microphone to the Adapter and the height of the centerline of the microphone to the Adapter.Acoustic Noise Test Set-Upt i mea ndA ll t hi 1.4 INRUSH CURRENTTest condition:For cold start test at room ambient, the adapter should be off for at least one hour at the test temperature to ensure it is at a uniform temperature before the test is started. Turn on the UUT at 90 degrees at positive cycle or 270 degrees at negative cycle. Between each test, the UUT shall be cooled down for at least 3 minutes and the Bulk Cap’s Energy is discharged.For hot start test at max. Operating ambient, the adapter should be on and running for at least one hour at the test temperature to ensure it is at a uniform temperature before the test is started.- Repetitive ON/OFF (1Sec. ON/1Sec. OFF for 10 times) cycling of the UUT and turn on at 90 degrees at positive cycle or 270 degrees at negative cycle. Between each test, the Bulk Cap’s Energy shall be discharged.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC LoadTektronix AM503 Current Probe Amplifier Tektronix A6303 Current Probe Tektronix TDS-5054 OscilloscopePass/Fail criteria:The inrush current shall meet the specification requirements.AC line inrush current shall not damage any components, nor cause the AC line fuse to blow, under any DC load conditions, any ambient temperature, and with any ac line input voltage and frequency.Test result: PASSExtended Name = Cold start 25 deg. ambient; after 1 hour in off stage Vin=90Vac Inrush Current=57.6A. 1).Vin 4).Iin Extended Name = Cold start 25 deg. ambient; after 1 hour in off stage Vin=264Vac Inrush Current=138.0A. 1).Vin 4).Iingareg oo d f or s o mExtended Name = Hot start 25 deg. ambient; Repetitive on/off cycle 10 times. Vin=90Vac Inrush Current=56.4A. 1).Vin 4).Iin Extended Name = Hot start 25 deg. ambient; Repetitive on/off cycle 10 times. Vin=264Vac Inrush Current=138.0A. 1).Vin 4).Iint i mea nd A ll t hi n gs int he i rb ei n 1.5 LINE CYCLE DROPOUTTest conditions:The unit is subjected to a dropout of the AC line voltage from 100Vac/50Hz to zero volt for duration which equal to 7mS repeated 10 times with a period of 1 second. The unit is fully loaded. Dropout shall occur at any input phase angle.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 Oscilloscope Tektronix P5100 ProbePass/Fail criteria:The unit test need not maintain within regulation but shall not latch off.Test result: PASSExtended Name = Dropout; 100Vac/50Hz (0 deg) Dropout 10 ms at Max. Load 1) Vin 2) Vo Extended Name = Dropout; 100Vac/50Hz (90 deg) Dropout 10 ms at Max. Load 1) Vin 2) VoExtended Name = Dropout; 100Vac/50Hz (270 deg) Dropout 10 ms at Max. Load 1) Vin 2) Vo1.6 BROWNOUT & BROWNOUT RECOVERYTest conditions:1. The input voltage decreases from 90Vac/50Hz down to zero in 30 minutes.2. The input voltage increases from 0Vac up to 90Vac/50Hz in 30 minutes.Test equipment:CHROMA 6530 AC SOURCE CHROMA 630XX DC LOADPass/Fail criteria:1. The input voltage below the minimum specifies shall not cause damage to the power supply unit (due to over-heating or otherwise).2. The PSU shall recover after an AC power reset.Test result:PASS @25 Cll t hi n gs in t he i rb ei 1.7 TOTAL HARMONIC DISTORTIONTest conditions:The power line is distorted (flat-topped) with a total harmonic distortion of up to 10% (100Vac @ 50 Hz with 10 % THD = 90 Vrms).Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 65909KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 Oscilloscope Tektronix P5100 Probe Pass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSExtended Name = Start up operation. 100Vac/50Hz @ Full Load (1) Vin (2) VoutExtended Name = Continuous operation. 100Vac/50Hz @ Full Load (1) Vin (2) Voutd A ll t hi n gs in t he i r1.8 LINE VOLTAGE SURGETest conditions:While the unit is operating with maximum continuous load, the line voltage is switched to the surge voltage as indicated below:• 220Vac to 286Vac for 1sec, and back to 220Vac at 50Hz, repeated 10 times with 10 seconds interval.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 Oscilloscope Tektronix P5100 Probe Pass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSExtended Name = Line Surge 220Vac to 286Vac for 1.0 sec. Full Load.1) Vin 2) Vod A ll t hi n gs in t he i r1.9 LINE VOLTAGE SAGTest conditions:While the unit is operating with maximum continuous load, the line voltage is switched to the sag voltage as indicated below:• 100Vac to 80Vac for 0.5 sec., and back to 100Vac at 50Hz, repeated 10 times with 10 seconds interval.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 Oscilloscope Tektronix P5100 Probe Pass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSExtended Name = Line Sag 100Vac to 80Vac for 500mS.1) Vin 2) Vo1.10 VOLTAGE DIP IMMUNITYTest conditions:While the unit is operating with maximum continuous load, the 100Vac/50Hz and 240Vac/50Hz line voltage is switched to the dip voltage as indicated below:• 30%, 60%, 100% dip voltage for:0.5cycle, 1cycle, 5cycle, 10cycle, 25cycle, 50cycle, 250cycle durationsTest equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadTektronix TDS-5054 OscilloscopePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSDip Voltage (Vin=100Vac/50Hz)Dip Voltage (Vin=240Vac/50Hz) Duration times30%60%100%30%60%100%0.5 cycle*1*1*1*1*1*11 cycle*1*1*1*1*1*15 cycle*1*1*2*1*1*210 cycle*1*2*2*1*1*225 cycle*1*2*2*1*1*250 cycle*1*2*2*1*1*2Note: *1 Output within spec & no damage; *2 Self shutdown & no damage1.11 HARMONIC CURRENTS & EN61000-3-2 PRE-COMPLIANCETest condition:The harmonic components are compared with the limits set for Class D equipment. The input voltage is set at indicated values and the harmonic current values are recorded and compared to the EN61000-3-2 requirements.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 OscilloscopePass/Fail criteria:The harmonic current values shall meet the EN61000-3-2 requirements.Test result: PASSVin(Vac)Fin(Hz)Iin(A)PF Pin(W)THD Test Result 100.00050.000 1.1350.858103.12339.090PASS 230.00050.0000.5020.791101.37446.140PASSInput(Vac)Standard ClassOrder Reading Limit %1 1.057**20.012**30.3730.80446.42040.007**50.1510.44933.66060.004**70.0470.23719.82280.004**90.0330.11827.895100.004**110.0450.08354.831120.005**130.0390.07056.063140.003**150.0240.06139.044160.002**170.0060.05410.634180.002**190.0120.04825.678200.002**210.0160.04336.866220.002**230.0050.04012.626240.002**250.0020.036 6.319260.002**270.0070.03419.881100.000JapanClass D280.002**290.0050.03116.879300.002**310.0060.02921.769320.001**330.0040.02813.043340.001**350.0060.02623.846360.001**370.0050.02521.951380.001**390.0030.02311.538400.001**10.456**20.006**30.2080.34560.45840.003**50.0190.1939.96960.002**70.0150.10115.08980.002**90.0070.05114.201100.001**110.0020.036 5.352120.001**130.0030.03010.333140.001**150.0030.02610.385160.001**170.0020.023 6.522180.001**190.0010.021 6.829200.001**210.0010.019 4.839220.001**230.0010.017 4.706240.000**250.0010.0167.051260.000**270.0010.014 3.448280.001**290.0010.014 5.926300.001**310.0010.013 5.556320.000**330.0010.012 5.085340.000**350.0000.011 1.786360.000**370.0010.010 4.762380.000**390.0000.0100.867230.000IEC-1000-3-2Class D400.001**B. OUTPUT CHARACTERIZATION2.1 LOAD, LINE/CROSS REGULATIONTest condition:Test is repeated from different input voltages. The output is at minimum load then at maximum. Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadPass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25︒CVin(V)Fre.(Hz)Power(W)Load(A)Vout(V)90.00047.0000.0730.00019.362100.00050.0000.073---19.360240.00060.0000.0730.00019.360264.00063.0000.073---19.36090.00047.00045.201 2.37019.103100.00050.00045.201---19.103240.00060.00045.201 2.37019.103264.00063.00045.189---19.09790.00047.00089.089 4.74018.825100.00050.00089.101---18.827240.00060.00089.077 4.74018.823264.00063.00089.054---18.825@0︒CVin(V)Fre.(Hz)Power(W)Load(A)Vout(V)90.00047.0000.1100.00019.360100.00050.0000.073---19.361240.00060.0000.0730.00019.360264.00063.0000.073---19.36090.00047.00045.657 2.37019.105100.00050.00045.663---19.103240.00060.00045.646 2.37019.108264.00063.00045.646---19.09790.00047.00090.296 4.74018.824100.00050.00090.098---18.827240.00060.00090.001 4.74018.823264.00063.00090.045---18.825@40︒CVin(V)Fre.(Hz)Power(W)Load(A)Vout(V) 90.00047.0000.0730.00019.380 100.00050.0000.073---19.380 240.00060.0000.0360.00019.380 264.00063.0000.073---19.380 90.00047.00045.320 2.37019.138 100.00050.00045.290---19.140 240.00060.00045.314 2.37019.135 264.00063.00045.278---19.135 90.00047.00089.314 4.74018.872 100.00050.00089.302---18.870 240.00060.00089.350 4.74018.880 264.00063.00089.361---18.875mea ndA ll t hi n gs in t he i r2.2 PEAK LOAD.Test conditions:The output regulation shall be kept for a period of 5Sec at 6.32A peak load from90W.Test equipment:Tektronix TCP-202 Current Probe Tektronix TDS-5054 OscilloscopePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25︒CVin (Vac)Fin (Hz)Initial Load(A)Surge Load(A)DurationTime(mS)Vout Max Spec.(V)Vout Min Spec.(V)Vout Max.(V)Vout Min.(V)Result 90.0047.00 4.74 6.325000.0019.9517.0018.9218.48PASS 264.0063.00 4.74 6.325000.0019.9517.0018.8818.52PASSExtended Name = 90Vac @Full load then peak to 6.32A 2). Vout 3). IoutExtended Name = 264Vac @Full load then peak to 6.32A 2). Vout 3). Iout@0︒CVin (Vac)Fin (Hz)Initial Load(A)Surge Load(A)DurationTime(mS)Vout Max Spec.(V)Vout Min Spec.(V)Vout Max.(V)Vout Min.(V)Result 90.0047.00 4.74 6.325000.0019.9517.0018.9218.52PASS 264.0063.00 4.74 6.325000.0019.9517.0018.9218.16PASSa nd A ll t hi n gs in t he i rb ega reg oo d f or s o mExtended Name = 90Vac @Full load then peak to 6.32A 2). Vout 3). Iout Extended Name = 264Vac @Full load then peak to 6.32A 2). Vout 3). Iout@40 CVin (Vac)Fin (Hz)Initial Load(A)Surge Load(A)DurationTime(mS)Vout Max Spec.(V)Vout Min Spec.(V)Vout Max.(V)Vout Min.(V)Result90.0047.00 4.74 6.325000.0019.9517.0018.9218.56PASS 264.0063.00 4.74 6.325000.0019.9517.0018.9218.32PASSExtended Name = 90Vac @Full load then peak to 6.32A 2). Vout 3). IoutExtended Name = 264Vac @Full load then peak to 6.32A 2). Vout 3). Ioutea nd A ll t hi n gs in 2.3 RIPPLE AND NOISE (P.A.R.D.)Test conditions:Ripple voltage and noise are measured at the pins of the mating connector of which each output is decoupled by a high frequency and tantalum capacitor. Bandwidth is set at 20MHz.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TCP202 Current Probe Tektronix P5100 ProbeTektronix TDS-5054 Oscilloscope Pass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS @25 CInput(Vac)FrequencyTotal Power (W)Load (A)PARD (mV)90470.070.00088.0264630.070.000112.0904789.07 4.740216.02646389.104.740180.0Extended Name = 90V/ 47Hz 0A 1) Vpk-pkExtended Name = 264V/ 63Hz 0A 1) Vpk-pknd A ll t hi n gs in t he i rb ei n a reg oo d f or s o Extended Name = 90V/47Hz Full Load 1) Vpk-pk Extended Name = 264V/ 63Hz Full Load 1) Vpk-pk @0 CInput(Vac)FrequencyTotal Power (W)Load (A)PARD (mV)90470.070.000107.2264630.070.000113.6904789.27 4.740264.02646389.294.740196.0Extended Name = 90V/ 47Hz 0A 1) Vpk-pkExtended Name = 264V/ 63Hz 0A 1) Vpk-pknd A ll t hi n gs in t he i rb ei n a reg oo d f or s o Extended Name = 90V/47Hz Full Load 1) Vpk-pk Extended Name = 264V/ 63Hz Full Load 1) Vpk-pk @40 CInput(Vac)FrequencyTotal Power (W)Load (A)PARD (mV)90470.070.000123.2264630.070.000160.0904789.46 4.740276.02646389.504.740252.0Extended Name = 90V/ 47Hz 0A 1) Vpk-pkExtended Name = 264V/ 63Hz 0A 1) Vpk-pka reg oo d f or s o Extended Name = 90V/47Hz Full Load 1) Vpk-pk Extended Name = 264V/ 63Hz Full Load 1) Vpk-pk2.4 DYNAMIC LOAD RESPONSETest conditions:The dynamic load response changes at a rate and load step and frequency change are basis specification defined.Test equipment:Chroma Model 8000 Power Supply Auto Test SystemChroma Model # 6590 9KVA Low Impedance AC SourceChroma Model # 630X0 DC LoadChroma Model # 6630 Power AnalyzerTektronix TDS-5054 OscilloscopeTektronix P5100 ProbeTektronix TCP202 Current ProbePass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASS@25 CDynamic load condition Vspec-max Vspec-min Vreading-max Vreading-min Test result90Vac/ 47Hz; 0%load ~50%load;100Hz; 1.0A/uS. 19.95018.55019.28118.908PASS264Vac/ 63Hz; 0%load ~50%load;100Hz;1.0A/uS. 19.95018.55019.29918.906PASS90Vac/ 47Hz; 50%load ~100%load;100Hz; 1.0A/uS. 19.95018.55019.04118.630PASS264Vac/ 63Hz; 50%load~100%load;100Hz;1.0A/uS.19.95018.55019.03018.681PASSt i mea nd A hi n gs in t he i rb ei n ga reg oo d f or s o mExtended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) Io@0 CDynamic load conditionVspec-max Vspec-min Vreading-max Vreading-min Test result 90Vac/ 47Hz; 0%load ~50%load;100Hz; 1.0A/uS.19.95018.05019.29018.928PASS 264Vac/ 63Hz; 0%load ~50%load;100Hz; 1.0A/uS.19.95018.05019.29118.926PASS 90Vac/ 47Hz; 50%load ~100%load;100Hz; 1.0A/uS.19.95018.05019.08118.677PASS 264Vac/ 63Hz; 50%load ~100%load;100Hz; 1.0A/uS.19.95018.05019.07318.677PASSt i mea nd t hi n gs in t he i rb ei n ga reg oo d f or s o Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) Io@40 CDynamic load condition Vspec-max Vspec-min Vreading-max Vreading-min Test result 90Vac/ 47Hz; 0%load ~50%load;100Hz; 1.0A/uS.19.95018.05019.27918.907PASS 264Vac/ 63Hz; 0%load ~50%load;100Hz; 1.0A/uS.19.95018.05019.28118.906PASS 90Vac/ 47Hz; 50%load ~100%load;100Hz; 1.0A/uS.19.95018.05019.04618.685PASS 264Vac/ 63Hz; 50%load19.95018.05019.03218.715PASSA ll t hi n gs in t he i rb ei n ga reg oo d f or s ~100%load;100Hz; 1.0A/uS.Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) Io Extended Name = 90Vac/ 47Hz; 0%load ~50%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) IoExtended Name = 90Vac/ 47Hz; 50%load ~100%load;100Hz;1.0A/uS. (1) Vo (3) Iomea nd A ll t hi n gs i2.5 OUTPUT OVER/UNDER SHOOTTest conditions:The power adapter unit was tested either at Turn On/Off or from Full Load to No Load.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 Oscilloscope Pass/Fail criteria:The unit test shall meet the specification requirements.Test result: PASSConditionOutput OvershootMax.(%)Output Overshoot Reading.(%)Output Voltage Max.(V)Output Voltage Reading.(V)Test Result Turn on overshoot; Vin=90Vac; No Load 10.00 1.63*19.53PASS Turn on overshoot; Vin=90Vac; Full Load 10.00 1.69*18.97PASS Turn on overshoot; Vin=264Vac; No Load 10.00 1.64*19.53PASS Turn on overshoot; Vin=264Vac; Full Load10.001.70*18.97PASSExtended Name = Turn on overshoot; Vin=90Vac; No Load 2) VoExtended Name = Turn on overshoot; Vin=90Vac; Full Load 2) Voga reg oo d f or s o mExtended Name = Turn on overshoot; Vin=264Vac; No Load 2) Vo Extended Name = Turn on overshoot; Vin=264Vac; Full Load 2) Voi mea nd A ll t hi n gs 2.6 TIMING REQUIREMENTSTest conditions:The following timings are measured:• AC Turn-on delay: Output voltage shall reach its nominal setting from AC power on.• AC Hold-up time: The output voltage shall remain its normal setting from AC power off.• DC output rise time: The output voltage rise time measured from 10% to 90%.• DC output fall time: The output voltage fall time measured from 90% to 10%.Test equipment:Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 Oscilloscope Tektronix P5100 ProbePass/Fail criteria:All parameters shall be within specification.Test result: PASSTiming Condition Vin(Vac)Freq(Hz)Spec Max.(mS)Spec Min.(mS)Reading(mS)Result Turn on 90Vac; Full Load 90.0047.00**168.40PASS Turn on 115Vac; Full Load 115.0060.003000.00*90.80PASS Turn on 230Vac; Full Load 230.0050.003000.00*122.00PASS Turn on 264Vac; Full Load264.0063.00**66.40PASSExtended Name = Turn on 90Vac; Full Load 1) Vin 2) VoExtended Name = Turn on 115Vac; Full Load 1) Vin 2) Vo。