当前位置:文档之家› DELL服务器错误代码汇总

DELL服务器错误代码汇总

5VPwrGd
High
5 V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1218
PCIRsr5VPwrGd
High
PCI Riser 5 V voltage regulator has failed.
AC Cycle or SEL clear
Failing device is reseated/replaced/repaired.
Yes
Any
E1A16
SAS Cable FB
Low
Flex bay SAS cable is missing or bad.
Failing device is reseated/replaced/repaired.
Any
Voltages -Message Code:"x12xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
Yes
Any
E1211
ROMBBatt
Low
PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly because of high temperatures), or the battery is bad.
AC Cycle or SEL clear
Yes
Any
E122A
CPU VTTPwrGd
High
Processor VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E122B
0.9 V Over Voltage
High
0.9 V regulator voltage has exceeded the allowable voltage range.
Failing device is reseated/replaced/repaired.
Yes
Any
Temperature -Message Code:"x11xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
AC Cycle or SEL clear
Yes
Any
E1227
LinearPwrGd
High
Linear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry.
Yes
Any
E1311
RPM Fan Mod #B
Low
Same as above except for fan B of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
Yes
Any
E1311
RPM Fan Mod #A
Low
RPM of fan A in the # module is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
DELL服务器错误代码汇总
Cable and Board Presence -Message Code:"x1Axx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
AC Cycle or SEL clear
Yes
Any
E1228
0.9VPwrGd
High
Memory VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1229
CPU # VCORE
High
Processor # VCORE voltage regulator has failed.
Yes
Any
E1116
Temp Memory
High
Memory has exceeded allowable temperature and has been disabled to prevent damage to the componenes
Battery charges to > 24 hours of sustained charge.
Yes
Any
E1214
1.5VPwrGd
High
1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1215
1.8VPwrGd
Yes
Pre-Post
E1A11
PCIRsrConfig
High
PCI risers are not configured correctly; some invalid configurations prevent system power on.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Yes
Any
W1228
ROMBBatt< 24 hr
Low
This is a predictive failure warning message telling the user that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer.
Yes
Any
E1219
BackplanePwrGd
High
Backplane voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1221
Flex BayPwrGd
High
Flex Bay voltage regulator power good has failed.
System Phase When Event Can Occur?
E1310
RPM Fan ##
Low
RPM of fan ## is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
Exists in SEL?
System Phase When Event Can Occur?
E1A10
PDBPwrCable
High
PDB power cable to the planar is missing or bad and system will not power on.
Failing device is reseated/replaced/repaired.
Yes
Any
Fans -Message Code:"x13xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
AC Cycle or SEL clear
Yes
Any
E1225
ESB 1.5VPwrGd
High
ESB 1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1226
PCIRsr1.5VPwrGd
High
PCI Riser 1.5 VV voltage regulator has failed.
Yes
Pre-Post
E1A12
PCIRsrMissing
High
One or all of the PCI risers is missing. This prevents system power on.