M – 160 所有电缆、气管和电线 Update 都必须使用线缆托架
cables, tubing and workpieces.
Note: Exceptions will be announced
at the briefing for each task.
M – 70
工具不得遗留到站上或 工作区域地面上。 Tools must not be left on the stations or the floor of workspace.
M – 130 工作站之间的最大间 距需≤5mm Maximum distance between stations: <= 5 mm
M – 140 所有型材末端必须安装 盖子。 All ends of profiles must be fitted with caps.
M – 150 固定任何一段线槽时都 应使用至少2个带垫圈的 螺丝。 Use at least 2 screws with washers to secure any section of cable channel.
M - 40 线缆托架的间距为 ≤120mm。 Distance between cable holders: < = 120 mm
M – 45a 电缆/电线/气管绑在线 夹子上 。 The only acceptable method for binding Cable
单根电线用绑扎带固定在线夹子上
M – 30 扎带的间距为≤50mm。这 一间距要求同样适用于 型材台面下方的线缆。 PLC和系统之间的I/O布 线不在检查范围内。 Distance between cable ties: <= 50 mm. This also applies to cables under the profile plate. I/O cabling between PLC and system will NOT be checked.
世界技能大赛
机电一体化项目专业技术规范
机械部分 MechanicalPP-Leabharlann Nr.okM - 10
型材板上的电缆和气管必 须分开绑扎。 Cable and tubes must be
routed separately on the
profile plate.
not ok
M – 15
当电缆、光纤电缆和气管 都作用于同一个活动模 块时,允许绑扎在一起。 It is allowed to route tubes, electrical and optical cables together when they go to a moving module.
shortest pneumatic
connection to the first
cable tie:
60 mm +/- 5mm
M – 60
所有活动件和工件在运 所有驱动器、线缆、气管和工件需能够 运行期间,不允许驱动器、线缆、
动时不得发生碰撞。 自由运动。
线管或工件间发生接触。
All actors and
注意:如有例外,将在每个任务开始前 Contact between actuators, cables,
workpieces have to move 的例会中进行通知。
tubing or workpieces during
without collisions.
Free movement of all actuators, operation.
M – 20 扎带切割后剩余长度需
≤1mm,以免伤人。
A
Remaining length of cut
cable ties, A: Risk of
injury
A <= 1 mm
M – 21
New 新增
Cable ties on the input and output side of a flexible cable duct / drag chain
软线缆或拖链的输入
和输出端需要用扎带
固定。
M – 25 所有沿着型材往下走的线 缆和气管(例如PP站点处的 线管)在安装时需要使用线 夹固定。 All cables and tubes going downwards on a profile e.g. at the “Pick & Place” station have to be mounted with cable clips.
and modules must be
secure.
All signal terminations
must be secure.
M - 100
不得丢失或损坏任何零 部件或组件(其中包括 电缆、线路等等) No parts or components
should be lost or damaged
(including cables, lines
M - 80
工作站上不得留有未 使用的零部件和工件。 Unused components and
workpieces must be
removed from the
stations.
M - 90
所有系统组件和模块 必须固定好。所有信号 终端也必须固定好。 All system components
and so on).
Components lost or damaged during completion of task 完成任务期间出现组件丢失或损坏
M – 110 站与站之间的错位需小 于等于5 mm 。 Station misalignment: <= 5 mm
M – 120 工作站的连接必须至少 使用 2 个连接件。 Adjoining stations must be connected with at least 2 connectors.
单根电缆/电线/气管没有紧固在线 夹子上
/ Wire / Optical Cables / Tubes is to use conducted cable holders.
M – 50 Update
第一根扎带离阀岛气 管接头连接处的最短 距离为 60 mm +/- 5 mm。 Distance from the