当前位置:文档之家› 本科毕业设计外文文献翻译

本科毕业设计外文文献翻译

(本科毕业设计外文文献翻译学校代码: 10128学 号:题 目:Shear wall structural design of high-level framework 学生姓名: 学 院:土木工程学院 系 别:建筑工程系 专 业:土木工程专业(建筑工程方向) 班 级:土木08-(5)班 指导教师: (副教授)Shear wall structural design of high-level frameworkWu JichengAbstract: In this paper the basic concepts of manpower from the frame shear wall structure, analysis of the structural design of the content of the frame shear wall, including the seismic wall shear span ratio design, and a concrete structure in the most commonly used frame shear wall structure the design of points to note.Keywords: concrete; frame shear wall structure; high-rise buildings The wall is a modern high-rise buildings is an important building content, the size of the frame shear wall must comply with building regulations. The principle is that the larger size but the thickness must be smaller geometric features should be presented to the plate, the force is close to cylindrical. The wall shear wall structure is a flat component. Its exposure to the force along the plane level of the role of shear and moment, must also take into account the vertical pressure. Operate under the combined action of bending moments and axial force and shear force by the cantilever deep beam under the action of the force level to look into the bottom mounted on the basis of. Shear wall is divided into a whole wall and the associated shear wall in the actual project, a whole wall for example, such as general housing construction in the gable or fish bone structure film walls and small openings wall. Coupled Shear walls are connected by the coupling beam shear wall. But because thegeneral coupling beam stiffness is less than the wall stiffness of the limbs, so. Wall limb alone is obvious. The central beam of the inflection point to pay attention to the wall pressure than the limits of the limb axis. Will form a short wide beams, wide column wall limb shear wall openings too large component at both ends with just the domain of variable cross-section rod in the internal forces under the action of many Wall limb inflection point Therefore, the calculations and construction shouldAccording to approximate the frame structure to consider. The design of shear walls should be based on the characteristics of a variety of wall itself, and different mechanical characteristics and requirements, wall of the internal force distribution and failure modes of specific and comprehensive consideration of the design reinforcement and structural measures. Frame shear wall structure design is to consider the structure of the overall analysis for both directions of the horizontal and vertical effects. Obtain the internal force is required in accordance with the bias or partial pull normal section force calculation. The wall structure of the frame shear wall structural design of the content frame high-rise buildings, in the actual project in the use of the most seismic walls have sufficient quantities to meet the limits of the layer displacement, the location is relatively flexible. Seismic wall for continuous layout, full-length through. Should be designed to avoid the wall mutations in limb length and alignment is not up and down the hole. The same time. The inside of thehole margins column should not be less than 300mm in order to guarantee the length of the column as the edge of the component and constraint edge components. The bi-directional lateral force resisting structural form of vertical and horizontal wall connected. Each other as the affinity of the shear wall. For one, two seismic frame shear walls, even beam high ratio should not greater than 5 and a height of not less than 400mm. Midline column and beams, wall midline should not be greater than the column width of 1/4, in order to reduce the torsional effect of the seismic action on the column. Otherwise can be taken to strengthen the stirrup ratio in the column to make up. If the shear wall shear span than the big two. Even the beam cross-height ratio greater than 2.5, then the design pressure of the cut should not make a big 0.2. However, if the shear wall shear span ratio of less than two coupling beams span of less than 2.5, then the shear compression ratio is not greater than 0.15. The other hand, the bottom of the frame shear wall structure to enhance the design should not be less than 200mm and not less than storey 1/16, other parts should not be less than 160mm and not less than storey 1/20. Around the wall of the frame shear wall structure should be set to the beam or dark beam and the side column to form a border. Horizontal distribution of shear walls can from the shear effect, this design when building higher longer or frame structure reinforcement should be appropriately increased, especially in the sensitive parts of the beam position or temperature,stiffness change is best appropriately increased, then consideration should be given to the wall vertical reinforcement, because it is mainly from the bending effect, and take in some multi-storey shear wall structure reinforced reinforcement rate - like less constrained edge of the component or components reinforcement of the edge component. References: [1 sad Hayashi, He Yaming. On the short shear wall high-rise building design [J].Keyuan, 2008, (O2).高层框架剪力墙结构设计吴继成摘要: 本文从框架剪力墙结构设计的基本概念人手,分析了框架剪力墙的构造设计内容,包括抗震墙、剪跨比等的设计,并出混凝土结构中最常用的框架剪力墙结构设计的注意要点。

相关主题