Item Description1.Local Legislative Requirements地方法律规定2.Sustainability and Green BuildingRequirements可持续性及绿色建筑规定3.Environment Quality环境质量a Indoor Air Temperature & Humidity室内温度及湿度Villas / Guestrooms别墅 / 客房Conference / Meeting rooms & publicfunctional Rooms会议室及公共活动室会议室 & 多功能房Restaurants餐厅Main Lobby / Reception大堂/ 接待室Transitional Area (Corridor)走廊b.Noise Requirement噪音要求Summary of BTHR Main M&E Design RequirementThe local legislative / statutory and building codes in the region shall govern and serves as a minimum requirement. In case of discrepancies, whichever criteria more stringent shall take precedent.应以As part of the sustainability initiatives for BTHR, all building should comply with international Green Building standards such as LEED and EC 3 Global. There should be close communication with the BTHR and CSR team on the above initiatives.作EIA to be undertaken by Owners由业主完成环境评估Summer : 23.5 degree C ± 1 degree C, RH 55%± 5%夏天:摄氏23.5度 ±1度,相对湿度 55%± 5%Winter : 21 degree C ± 1 degree C. RH 30%-55%冬天:摄氏21度 ±1度,相对湿度 30%-55%Summer : 20 - 23.5 degree C ± 1 degree C, RH 55%± 5%夏天:摄氏20-23.5度 ±1度,相对湿度 55%± 5%Winter : 21 degree C ± 1 degree C. RH 30%-55%冬天:摄氏21度 ±1度,相对湿度 30%-55%Summer : 20 - 23.5 degree C ± 1 degree C, RH 55%± 5%夏天:摄氏20-23.5度 ±1度,相对湿度 55%± 5%Winter : 21 degree C ± 1 degree C. RH 30%-55%冬天:摄氏21度 ±1度,相对湿度 30%-55%Adequate fresh air and exhaust should be allowed for this area.区域内Summer : 23 degree C ± 1 degree C, RH 55%± 5%夏天:摄氏23度 ±1度,相对湿度 55%± 5%Winter : 21 degree C ± 1 degree C. RH 30%-55%冬天:摄氏21度 ±1度,相对湿度 30%-55%Summer : 25 - 26 degree C ± 1 degree C, RH 55%± 5%夏天: 摄氏25-26度 ±1度,相对湿度 55%± 5%Winter : 21 degree C ± 1 degree C. RH 30%-55%冬天: 摄氏21度 ±1度,相对湿度 30%-55%The noise level shall conform to the following :噪声水平Villa / Guestroom - NC 25~30 (dbA 30~35)别墅Conference / Meeting room - NC 30~35 (dbA 35~40)会Item Description1.Local Legislative RequirementsSummary of BTHR Main M&E Design Requirement Restaurant - NC 35 (dbA 40)Item Description1.Local Legislative RequirementsSummary of BTHR Main M&E Design Requirement Should maintain a temperature of 26 deg C. For larger unit toilet, AC outlet may have to be provided.Item Description1.Local Legislative RequirementsSummary of BTHR Main M&E Design Requirement - Guest drop off porch (“Porte Cochere”)Item Description1.Local Legislative Requirementsc.Electronic Card Key Lock SystemSummary of BTHR Main M&E Design RequirementElectronic lock set used shall be of international reputable brands for use in Hotels. Consideration should be given to cost of replacement cards, availabilityItem Description1.Local Legislative Requirementsc.Incoming Breaker at Distribution PanelSummary of BTHR Main M&E Design Requirement1 distribution panel shall be provided for each villa. It must be located in a easily accessible area (preferably within the cabinet) and properly coordinatedItem Description1.Local Legislative RequirementsSummary of BTHR Main M&E Design Requirement ElevatorsItem Description1.Local Legislative Requirementsa.Energy Saving Key Card SystemSummary of BTHR Main M&E Design RequirementThe master card control system shall control all indoor power and lighting supply except fridge ,mini safe, study table power point (for charging battery) TVItem Description1.Local Legislative RequirementsSummary of BTHR Main M&E Design Requirement - Kitchen / RestaurantItem Description1.Local Legislative RequirementsSummary of BTHR Main M&E Design RequirementLighting in common areas i.e. common corridor, car park, and external lighting may be controlled by timer and BMS system. Lighting circuits to be wired toItem Description1.Local Legislative Requirements 10.Building Management SystemSummary of BTHR Main M&E Design Requirement Building Management System shall be provided to monitor the following :Item Description1.Local Legislative Requirementsb.Cooling medium to be considered forSummary of BTHR Main M&E Design RequirementChilled pool shall be provided. Temperature shall be between 25 deg C (subject to final design based on specified property requirement). Ventilation withItem Description1.Local Legislative Requirementsf Emergency LightSummary of BTHR Main M&E Design Requirement Other than the code requirement, min. 1 no. of emergency light shall be provided at the vestibule of the guestroom.Item Description1.Local Legislative Requirements 15.Plumbing & SanitarySummary of BTHR Main M&E Design RequirementAs part of the Green Initiative, design and proposal should target to achieve 20% (Average) Water Saving. The initiative can consider the following :Item Description1.Local Legislative RequirementsSummary of BTHR Main M&E Design Requirement Requirement to conform to CIBSE Standard。