1001- 4322(2012)07-1575-04
同步辐射标定闪烁体探测器灵敏度
何小安1杜华冰1李朝光1易荣清1肖体乔2
1.中国工程物理研究院激光聚变研究中心,四川绵阳621900;2.中国科学院上海应用物理研究所,上海201800
摘要: 利用上海同步辐射光源BL13W1光束线开展了闪烁体探测器的灵敏度标定方法的研究。
对光源的高次谐波以及闪烁体探测器的工作线性动态范围进行了实验研究,在此基础上建立了一种新的同步辐射标定闪烁体探测器灵敏度的方法。
通过对实验结果的理论拟合,得到与放射源方法相符合的灵敏度数据,验证了方法的准确性,提高了标定数据的精度。
同步辐射; 闪烁体探测器; 灵敏度; 等离子体
TN247 A10.3788/HPLPB20122407.15752012-03-262012-05-21
何小安(1984-),男,从事激光聚变X射线诊断工作;hexiaoan1984@163.com。
£减,观察_区,则探测;测器信号
@@[1] McDonald J W, Suter L J, Landen O L, et al. Hard X-ray and hot electron environment in vacuum hohlraums at the National Ignition Facili
ty[J]. Phys Plasmas, 2006, 13:032703.
@@[2] Juan C F, Goldman SR, KlineJ L, et al. Gas-filled hohlraum experiments at the National Ignition Facility[J]. Phys Plasmas, 2006,13: 056319.
@@[3]蔡涓涓,黄文忠,谷渝秋,等.双荧光层靶Ka线强度比诊断靶内超热电子温度[J].强激光与粒子束,2011,23(5):1303-1306.(Cai Juanjuan,Huang Wenzhong, Gu Yuqiu, et al. Diagnosis of hot electron temperature by ratio of Kα lines from two-layer fluorescent target. High Power Laser and Particle Beams, 2011 , 23(5) : 1303-1306)
@@[4]蔡达锋,王剑,谷渝秋,等.超热电子能量分布的实验和模拟研究[J].强激光与粒子束,2011,23(7):1945-1948.(Cai Dafeng, Wang Jian,Gu Yuqiu, et al. Experimental and simulative study on energy distribution of hot electrons. High Power Laser and Particle Beams, 2011, 23 (7) : 1945-1948)
@@[5] McDonald J W, Kauffman R L, Celeste J R, et al. Filter-fluorescer diagnostic system for the National Ignition Facility[J]. Review of Scien tific Instruments, 2004, 75(10):3753-3755.
@@[6] Bruns H C, James A E, Thoe S R, et al. Filtered Fluoresscer X-ray Detector[R]. UCRL-JC-119323,1995.
@@[7] 汪晓莲.粒子探测技术[M].合肥:中国科学技术大学出版社,2009:232-234.(Wang Xiaolian.Detector technology of particle.Hefei: University of Science and Technology of China, 2009:232-234)
@@[8]久米英浩,冈野和芳,酒井四郎,等.光电倍增管[M].日本:滨松光子学株式会社,1993:126-129.(Jiumi Yinghao,Gangye Hefang, Jiujing Silang, et al. Photomultiplier. Japan: Hamamastu, 1993:126-129)
@@[9]李三伟,祁兰英,易荣清,等.激光聚变中硬X光谱回推方法[J].强激光与粒子束,1995,7(2):205-209.(Li Sanwei,Qi Lanying,Yi Rongqing, et al. A unfolding of hard X-ray spectrum in laser fusion. High Power Laser and Particle Beams, 1995, 7(2) :205-209)
Scintillator's sensitivity calibration method
in synchrotron radiation facility
Du HuabingLi ChaoguangYi RongqingXiao Tiqiao