交联聚乙烯绝缘阻燃电力电缆

0.6/1kV 交联聚乙烯绝缘阻燃电力电缆XLPE Insulated Flame-retardant Power Cable一、产品标准Standard本产品按GB12706-91《额定电压35kV及以下铜器芯、铝芯塑料绝缘电力电缆》、GB12666.5-90《电线电缆成束燃烧实验》、IEC60754《取自电缆或光缆的材料燃烧时释放出气体的试验方法》和IEC61034《电缆或光缆在特定条件下燃烧的烟密度测定》标准生产,同时还可根据用户需要按国际电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。

The product is manufactured according to the standard of GB12796-91 and GB12666.5-90 or IEC、BS、DIN and ICEA upon request. 二、适用范围Application本产品适用于工频额定电压0.6/1kV及以下配电线路作配送电能之用。

The product is suitable for use in power distribution lines with rated power-frequency voltage up to and including0.6/1kV.三、使用特性Operating characteristics·工频额定电压U0/U为0.6/1kV。

Rated power-frequency voltage U0/U为0.6/1kV.·电缆导体的最高允许工作温度为90℃。

Max. permissible continuous operating temperature of conductor :90℃.·短路时(最长持续时间不超过5S)电缆导体的最高温度不超过250℃。

Max. Short –circuit temperature of the conductor shall not exceed 250℃.(5s maximum duration).·电缆敷设时环境温度应不低于0℃。

The ambient temperature under installation should not below 0℃.·电缆的阻燃性能符合GB12666.5-90标准A级或C级要求。

The flame retardant performance of cable is in according with A or C grade request of GB12666.5-90.·低烟无卤电缆的无卤性能符合IEC60754《取自电缆或光缆的材料燃烧时释放出气体的试验方法》电缆燃烧时气体逸出试验。

The low smoke and non halo of cable is in according with IEC60754成品电缆燃烧时绝缘和护套材料的PH值和电导率符合下表的规定。

When end product burning.PH value and conductivity of insulation and sheath material should suit infra –table·低烟无卤电缆的低烟性能符合IEC61034《电缆或光缆在特定条件燃烧的烟密度测定》电缆燃烧烟密度试验。

The low smoke and non halo of cable is in according with IEC61034成品电缆燃烧时的最小透光率不小于30%。

When end product burning,the minimum light transmittance should not less than 30%.·电缆弯曲半径不小于电缆外径15倍。

The bending radius of cable should not less than 15 times of the cable diameter.四、电缆的型号、名称和使用范围Type Designation &Application of cable.五、生产范围Production Range of nCable*单芯铠装电缆仅用于直流系统,若用于交流系统,应采用非磁性材料铠装或隔磁措施。

*The single core armored cables are used for D.C Systenm only.As for A.C system,the magnetic isolation should be applied on the steel armor wires or non-magnetically materials should be used.六、电缆结构尺寸及主要技术参数Construction and Main technical data0.6/1KV单芯交联聚乙烯绝缘阻燃电力电缆0.6/1kv Signie Core XLPE Insulated Flame – retardant Power Cable注:#表示导体为紧压圆形Where:# = compact circular standed conductor0.6/1kv两芯交联聚乙烯绝缘阻燃电力电缆0.6/1kv 2 Cores XLPE Insulated Flame –retardant Power0.6/1kv两芯交联聚乙烯绝缘钢带铠装阻燃电力电缆0.6/1kv 2 Cores XLPE Insulated Steel Tape Armoured Flame –retardant Power0.6/1kv两芯交联聚乙烯绝缘钢丝铠装阻燃电力电缆0.6/1kv 2 Cores XLPE Insulated Steel wire Armoured Flame – retardant Power Cable0.6/1kv三芯交联聚乙烯绝缘阻燃电力电缆0.6/1kv 3 Cores XLPE Insulated Flame – retardant Power Cable.0.6/1kv三芯交联聚乙烯绝缘钢带铠装阻燃电力电缆0.6/1kv 3Cores XLPE Insulated Steel Tape Armoured Flame – retardant Power Cable.0.6/1kv三芯交联聚乙烯绝缘钢丝铠装阻燃电力电缆0.6/1kv 3Cores XLPE Insulated Steel Wire Armoured Flame – retardant Power Cable.0.6/1kv四芯交联聚乙烯绝缘阻燃电力电缆0.6/1kv4Cores XLPE Insulated Flame – retardant Power Cable.0.6/1kv四芯交联聚乙烯绝缘钢带铠装阻燃电力电缆0.6/1kv4Cores XLPE Insulated Steel Tape Armoured Flame – retardant Power Cable0.6/1kv四芯交联聚乙烯绝缘钢丝铠装阻燃电力电缆0.6/1kv4Cores XLPE Insulated Steel Wire Armoured Flame – retardant Power Cable.0.6/1KV五芯交联聚乙烯绝缘阻燃电力电缆0.6/1kv 5 Cores XLPE Insulated Flame – retardant Power Cable0.6/1KV五芯交联聚乙烯绝缘钢带铠装阻燃电力电缆0.6/1kv 5 Cores XLPE Insulated Steel Tape Armoured Flame – retardant Power Cable0.6/1KV五芯交联聚乙烯绝缘钢丝铠装阻燃电力电缆0.6/1kv 5 Cores XLPE Insulated Steel Wire Armoured Flame – retardant Power Cable注:#表示导体为紧压圆形;Where:# = compact circular standed conductor七、电缆载流量Currenrt Carrying Capacity ·空气中敷设In air空气中敷设In air直埋敷设Direct Burial直埋敷设Direct Burial电缆敷设运行条件Installation·在空气中敷设In air1、单芯电缆平行敷设时中心距离:185 mm2及以下为电缆直径的2倍;240mm2及以下为90mm。

2、周围环境温度:40℃3、导电线芯最高允许温度:90℃。

4、不同环境温度下载流量的校正系数:1、As the single core cable laying in parallel,the distance between the cables center is 2 times of the cable diameter, which cross sectional ares of conductor≤182 mm2 and 90mm,which cross sectional ares of conduatcor ≥240 mm22、Ambient temperature: 40℃3、Max. Temperature of conductor: 90℃。

4、Rating factors of current for ambient temperature.·直埋敷设Direct in ground1、单芯电缆不接触敷设时中心距离为电缆直径的2倍。

2、周围环境温度:25℃3、导电线芯最高允许温度:90℃4、土壤热阻系数:1.0℃.m/W5、直埋深度:0.7m6、不同环境温度下载流量的校正系数:1、When the single core cables are installed separately, the distance between the cable’s center is 2 times of the cable diameter.2、Ambient temperature: 25℃.3、Max.Temperature of conductor:90℃.4、Soil therm our resistively:1.0℃.m/W5、Depth:0.7m6、Rating factors of current rating for ambient temperature.20 ℃25 ℃30 ℃35 ℃40 ℃环境温度AirTemperature校正系数Rating factor 1.04 1.00.960.920.87。