Section A Architectural Requirement
章节A 建筑要求
Separate street entrances shall be providedfor hotel guests, employees
andgoods. Separate streetentrance is desirable for Ballroom,Restaurants
or Lounge and Theme/Specialty Bars.
应专门为酒店客人,员工和货物提供分开的临街入口。
宴会厅,餐厅或酒廊和主题/特种酒吧等也最好能有独立的临街入口。
The Loading Dock and Employees’ Entranceis to be separated from guest
entrances and well shielded from public areas and guest r ooms. Security by
means of gates or roller shutter is required.
卸货及员工入口与住客入口处是分开的,并应很好地避开公共区域和客房的视线。
要求手段闸门或卷帘门等安全设施。
An entrance canopy mustbe provided.
必须设有一个入口雨篷。
Entry driveway to have a minimumof three lanes.
入口至少需3个车道
Minimum height:5.0mclear
最低净高为5 米
Must extend to cover a minimum of two vehicular drop-off lanes,with an
additional by-pass lane.
必须延伸覆盖至少两个汽车落客通道,外加一个直通车道
Three flag poles mustbe provided, located in the vicinity o the main hotel
entrance. Five flagpoles are recommended for gateway properties. Flag
poles to be floodlit.
酒店主入口附近,必须设置3根旗杆,大城市最好有5 根旗杆。
旗杆应由泛光灯
照明。