HXD3C 机车故障处理以及排查方法1.升不起弓......................................................................................... .. (1)2.降不下弓......................................................................................... ............................................3.运行中自动降弓......................................................................................... .................................4.主断合不上......................................................................................... ........................................5.主断合上后立即断开......................................................................................... ............................6.主断断不开......................................................................................... .........................................7.主断异常......................................................................................... ............................................8.提牵引主手柄,或途中无牵引力......................................................................................... .......9.空压机不打风......................................................................................... ......................................10.提主手柄,牵引力矩异常处理......................................................................................... .........11.机车中高速运行时,严重抖动......................................................................................... ..........故障及主接地处理......................................................................................... .......................13.辅助回路接地,跳主断,或一直合不上主断处理....................................................................14.主变压器原边过流处理......................................................................................... .....................15.空压机打风排风不止......................................................................................... .........................16.油泵故障处理......................................................................................... ....................................17.油流继电器故障处理......................................................................................... .........................18.主变油温继电器动作处理......................................................................................... .................19.牵引风机故障处理......................................................................................... ............................20.牵引风机风速继电器故障处理......................................................................................... .........21.复合冷却器风机故障处理......................................................................................... .................显示屏报牵引电动机过流、PG 输出异常故障处理......................................................23.关于手柄极位与TCMS 显示器不匹配的问题..........................................................................24、机车行驶中,停车制动红灯亮起,无动力输出的处理.........................................................25.不撒砂或打换向手柄后一直撒砂......................................................................................... .....26.警惕装置故障处理、检查......................................................................................... .................27.微机屏白屏或触摸点漂移处理......................................................................................... .........28、制动屏运行中黑屏......................................................................................... .........................29.110V 充电装置(PSU1、PSU2)故障(DC110V 运转停止)..............................................1.升不起弓⑴检查风路。
检查升弓气路风压是否高于480Kpa,在初次升弓时,如风压低于480Kpa 时,辅助风泵会自动打风,当达到735Kpa 时,辅助风泵打风停止,这时,受电弓没有什么任何反应,要断开升弓搬键开关,再闭合一次升弓开关,受电弓就能升起了。
也可以手动一直按着管路柜上的“辅压机”按钮不松,手动打风到735Kpa,再进行手动升弓。
⑵检查气路中的各个阀门在正常开启状态。
确认管路柜上总风塞门在开启位,管路柜升弓模块U43-13在开启位,管路柜上U99 塞门在开启位,此阀门是一个蓝色钥匙,应处于垂直位置,且蓝色钥匙拔不出来。
⑶检查升弓塞门U98,应置于打开位置,I 端塞门在控制电器柜后面墙上,II 端塞门在管路柜后面墙上。
⑷检查控制电器柜上的各种电器开关位置,应置于正常闭合位置,如有跳开现象,请检查确认后,合上开关。
⑸合受电弓开关,听升弓电磁阀是否有得电声音,如有声音,说明有升弓电信号输出,只要风路满足条件,受电弓就能升起。
如听不到声音,则要看一下微机显示屏检修状态下信号信息画面。
查询方法是触摸微机屏上“检修状态”,输入“000”后点确认,然后点击“信号信息”,通过翻页即能看到相应的线号状态。
如451(452)是绿颜色,说明微机有电信号输出,可查一下微机柜内PAN1(PAN2)继电器状态,以及110 伏电源有没有送到电磁阀,或者检查电磁阀是否故障。
如451(452)是黑颜色,说明还不具备升弓条件,要查一下微机显示屏检修状态下信号信息画面,如在I 端升I 端弓,421、425、501、515 为绿色,427、434、448、812、829 为黑色。
如没有库用转换装3VL 断路器5SJ 断路器万转开关端子台电度表3VU 断路辅助连接汇流母排按上述显示,查找并解决相应故障点,解决后就可以正常升弓了。
⑹检查受电弓上快速降弓阀应在关闭位。
⑺如受电弓在升弓中半途自动降下,调整升弓时间,使其缩短,经验值是合升弓搬键开关到受电弓接触到接触网的时间是12 秒,如时间过长,比如30 秒,微机没有在规定时间内收到448(449)的低电平信号,微机就认为受电弓气路漏风,发出降弓指令。
或者检查确认滑板条没有漏风现象,受电弓就能顺利升起。
⑻在冬季冰雨、雨雪天气,机车长时间停放,受电弓可能被冻住,各种功能均正常也升不起弓,这时在有条件的情况下,到车顶清理受电弓,如无条件则可将升弓压力调大,直至受电弓升起,然后再调回原来的压力,大约。