当前位置:
文档之家› Copes-vulcan调节阀使用维护手册
Copes-vulcan调节阀使用维护手册
第二部分 维 护......................................................................................................... 9 2.1 注意事项......................................................................................................... 9 2.2 例行检查......................................................................................................... 9 2.3 从调节阀上拆卸执行机构.............................................................................. 11 2.4 解体调节阀 ................................................................................................... 11 2.5 装配调节阀 ................................................................................................... 14 2.6 装配执行机构................................................................................................ 19 2.7 研磨阀塞及套筒 ............................................................................................ 20
SD 系列调节阀可配置特殊的阀芯,对于这种配置 DeZURIK Copes-Vulcan 公司将提供 相应的手册。
带快速更换内部部件的单座“SD”调节阀 安装、运行、维护手册
第一部分 安 装
1.1 验 收
当收到阀门后应立即开箱检查阀门是否在运输过程中有损伤,同时对照每个 阀门均配备的装箱单确认阀门及配件与装箱单是否相符。
如果采用“U”杯型密封,那么必须同时配备定位环〔18b〕及定位持环〔18c〕。
阀座既可以是金属的也可以是非金属的,对于非金属阀座而言除了金属阀座〔5〕之外, 还包含有一个嵌入金属阀座内的非金属阀座〔21〕。
变径阀塞也就是阀塞尺寸较阀体尺寸小,因此,这种阀塞需配备另外一个阀塞密封垫圈 〔16〕及变径持环〔20〕。
法兰连接 - 管道侧的法兰接口必须平直对准阀门安装,否则管道上的张力将 使阀门变形并诱发运行故障。
焊接连接 - 管道接口必须平直对准阀门焊接,否则管道上的张力将使阀门变 形并诱发运行故障。应根据不同的阀体/管道材料采用适当的热处理方式及正 规的焊接工艺。
至于是否要将阀塞拆除后才能进行焊接的问题,通常取决于安装公司的习惯 做法,一般来说正确的焊接工艺过程不会对阀塞造成任何损伤,但对于有非 金属阀座或配有“U”杯型密封的平衡式阀塞来说,如果此类阀塞结构在焊 接过程中可能会遭受超过 500°F 或 260℃以上的温度,那么就必须将阀塞拆 除后再进行焊接,重新装配阀门时要使用新密封垫圈及密封。
表1
紧固力矩 ................................................................................................... 25
表2
阀塞和阀杆组件紧固力矩 .......................................................................... 26
如果要通过冲洗来清除调节阀内的铁渣和碎片,则应事先取出阀塞,避免受 损。
如果决定焊接过程中不将阀塞取出,则在焊接和焊后热处理过程中使调节阀 处于中间行程位置。
焊后热处理只能就地进行。进行焊后热处理时,不要用热处理材料将阀体完 全包住。
就地焊后热处理过程包括将管道/阀门上的一段加热到指定的温度范围。焊缝 两边的最小加热段宽度,管道表面最亮,应为焊接厚度或 2”(51mm)中较小 的一个。
图1
调节阀剖面图 ............................................................................................ 22
图2
螺栓紧固顺序 ............................................................................................ 24
为了不破坏热梯度,调节阀/管道上温度控制区向外的温度应逐渐减小。应监 视阀体腹板的温度为避免损坏元器件,该温度不应超过 450°F(232℃)。
带快速更换内部部件的单座“SD”调节阀 安装、运行、维护手册
COPES-VULCAN
SPX Process Equipment Installation & Instruction Manual
Customer Purchase Order Numer: Copes-Vulcan Job Number: Ultimate User:
第一部分 安 装......................................................................................................... 6 1.1 验 收 ............................................................................................................ 6 1.2 储 存 ............................................................................................................ 6 1.3 安 装 ............................................................................................................ 6 1.4 调试前复检 ..................................................................................................... 8 1.5 执行机构及配件 .............................................................................................. 8 1.6 运行要求......................................................................................................... 8
带快速更换内部部件的单座“SD”调节阀 安装、运行、维护手册
2. 安装维护手册目录
引 言........................................................................................................................... 5
Equipment:
STATE SOURCEHale Waihona Puke PW06007 PW06007
C-V Job No.: 0610-125145
DONGFANG BOILER YAOMENG POWER PLANT SD CONTROL VALVE
带快速更换内部部件的单座“SD”调节阀 安装、运行、维护手册
1. 阀门参数表和图纸
每个阀门由几个分项组件组成。例如在图一中,阀体组件包含阀体〔1〕、阀盖螺栓〔13〕 及阀盖螺母〔14〕和阀盖/阀体密封垫圈〔15〕。
阀盖组件包含阀盖〔2〕、盘根螺栓及螺母〔11〕和〔12〕,及根据阀门与执行机构的 几种不同连接方式所需要配备的零件:压块连接包含压块〔22〕及内六角螺栓〔23〕; 螺杆连接包含螺纹环〔32〕;螺栓连接包含螺栓〔33〕和螺母〔34〕。
COPES-VULCAN
带快速更换 内部部件的单座“SD”调节阀 安装、运行、维护使用说明书
SINGLE WEB “SD” TYPE CONTROL VALVE WITH QUICK CHANGE TRIM
邦源动力及控制(国际)有限公司
Bang uan State Source Power& Control Int’l LTD.
带快速更换内部部件的单座“SD”调节阀 安装、运行、维护手册
引言
SD 型调节阀是用于高温高压工况下的调节阀,其尺寸范围为 3/4”、1”、1.5”、2”、3”、6”、 8”、10”、12”、14”和 16”(20mm、25 mm、40 mm、50 mm、80 mm、150 mm、200 mm、 250 mm 和 300 mm、350 mm、400 mm),ANSI 压力磅级由 150 磅级到 2500 磅级。
定位 在安装之前,应预先考虑阀门周边留有足够的空间做维修保养、解体阀门或 执行机构。 对于较大尺寸的阀门,更应考虑留有足够的空间使用起吊设备。 阀门应安装在直管段上,并尽可能避开弯管或流体流速较高的管段,较理想 的位置是阀门入口之上游 10 倍于管道直径的直管段,阀门出口之下游有 5 倍于管道直径的直管段。 尽可能将阀门垂直安装,如果受场地限制而必须水平或某一角度安装,那么 必须谨慎考虑相应的支承问题,特别是那些配有较大执行机构的阀门。 如果阀门必须水平或某一角度安装,安装单位或用户必须事先通知 DeZURIK Copes-Vulcan 公司。 阀门本体进口处镶有“进口”标牌,请将此处对准阀门上游管道进行安装。