当前位置:文档之家› 颈动脉产品介绍 - 支架-in service

颈动脉产品介绍 - 支架-in service


®
支架 • 自膨支架 • Elgiloy® 金属丝 • 编制管状网眼结构
支架输送系统 – Monorail™ 导管设计,0.014“导丝输 送系统; – 5F (6 & 8 mm) 和 6F (10 mm) 低外 廓,高柔顺性;
2
2
Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally
Does Free Cell Area Influence the Outcome in Carotid Artery Stenting?
Bosiers et al. Eur J Vasc Endovasc Surg 2007;33:135-141.
• 闭环支架定义为支架网孔面积< 5.0mm2
– 例如 • Carotid WALLSTENT® Endoprosthesis • XACT® Carotid Stent
Carotid WALLSTENT
TM
颈动脉支架
1
Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally
Carotid WALLSTENTTM 颈动脉支架
• 开环支架定义为支架网孔面积> 5.0mm2
– 例如
– Precise® Rx Nitinol Stent System – RX Acculink® Carotid Stent
Precise is a trademark of Cordis Corporation, Acculink is a trademark of Abbott Cardiovascular Systems, Inc, and Xact is trademark of MedNova, Ltd. Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally Does Free Cell Area Influence the Outcome in Carotid Artery Stenting? Bosiers et al. Eur J Vasc Endovasc Surg
of connecting struts. Smaller number =
支架设计-闭环 Vs. 开环 • 闭环支架设计
– Carotid WALLSTENT® Endoprosthesis – Xact® Carotid Stent
• 开环支架设计
– Precise® PRO Rx Nitinol Stent System – RX Acculink® Carotid Stent
3
Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally
Carotid WALLSTENTTM 颈动脉支架
闭环单元结构,独特的支架设计提供 • • • 最大化的斑块覆盖 高度的柔顺性 便于使用的输送系统
1. Does Free Cell Area Influence the Outcome in Carotid Artery Stenting? Bosiers et al. A retrospective analysis of 30 day outcomes of a carotid artery stenting multicenter database consisting of 3179 consecutive patients
– TIA,死亡, 大和小卒中(非心肌梗死)
• 共3179接受颈动脉支架手术的患者
• 4个中心
– – – –
9
Bosiers, Deloose - Belgium Peeters, Verbis - Belgium Setacci, Donato et al. - Italy Cremonesi, Castriota - Italy
Does Carotid Stent Design Influence Outcomes? Bersin. Catheterization and Cardiovascular Interventions 2008;
72:863–866.
8
Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally
Cell Area: Measures the average area (mm2)within the perimeter Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally 4 *Free smaller free cell area.
Does Carotid Stent Design Influence Outcomes?
R. M. Bersin, Catheterization and Cardiovascular Interventions 2008; 72:863–866
目前为止,已经完成3项有关颈动脉支架设计与临床结果的回顾性、非随机 研究。
Carotid WALLSTENT Endoprosthesis
Precise PRO Rx Nitinol Stent System
RX Acculink Carotid Stent
Precise Pro is a trademark of Cordis Corporation, Acculink is a trademark of Abbott Cardiovascular Systems, Inc, and Xact is trademark of MedNova, Ltd. Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally 5 Images taken by and on file at BSC. Illustrations by BSC.
闭环支架设计
Carotid WALLSTENT® 闭环设计提供最大化的斑块覆盖
以及光滑平整的管腔
• CWS与其他颈动脉支架相比,具 有最小的支架网孔面积**
*Free Cell Area: 测量支架连接小杆周长间的平均面积 数值越小=支架网孔面积越小
**Testing performed on Carotid WALLSTENT Endoprosthesis 8mm x 21mm, Precise Pro RX 8mm x 40mm, RX ACCULINK 7-10mm x 40mm, Xact 7-9mm x 40mm. Bench test results may not necessarily be indicative of clinical performance. Test results shown are for models deemed most typically selected for placement in common carotid artery with a reference diameter of <8mm. Other models were also tested and yielded similar results. N=3. Data on file. Precise Pro is a trademark of Cordis Corporation, Acculink is a trademark of Abbott Cardiovascular Systems, Inc, and Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally 6 Xact is trademark of MedNova, Ltd.
Does Free Cell Area Influence the Outcome in Carotid Artery Stenting?
Bosiers et al. Eur J Vasc Endovasc Surg 2007;33:135-141.
• 目的: 明确颈动脉支架设计,尤其是支架网孔面积,对于颈动脉支架术后 30天卒中、死亡或TIA的影响。 • 30天结果的回顾性分析
3. Schillinger M, Gschwendtner M, Reimers B, et al. Does carotid stent cell design matter? A retrospective, nonrandomized review of a carotid artery stenting multicenter database consisting of 1,684 consecutive patients
闭环支架设计
Carotid WALLSTENT® 闭环设计提供最大化的斑块覆盖 以及光滑平整n by Boston Scientific Corporation
Boston Scientific Confidential -- For Internal Use Only. Do Not Copy, Display or Distribute Externally