米箱梁张拉伸长量计算程序表
L2
L3=圆周率/180*切角*半 径
L4
9.9680
3.927
0.885
8.3615
3.927
2.507
6.7555
3.927
4.129
1.0665
0.733
12.901
8.1880
3.927
2.693
6.6230
3.927
4.263
4.9975
3.927
5.893
1.0165
0.733
13.001
L=从张拉端至计算截面的孔道长度
L/2
15.4300 15.4455 15.4615 15.3505 15.4580 15.463 15.4675 15.4005
序号
线段
L1
N1
L2
L3
L4 合计
L1
N2
L2
L3
L4计
L1
N4
L2
L3
L4
合计
30米中跨预应力箱梁张拉伸长量计算表
P(N) 781.20 585.90 781.20
Ep(Mpa) 195000 195000 195000
Ay(mm2) 560 420 560
ΔL(mm) 备注 25.038 50.07692 35.769 71.53846 53.654 107.3077
951.3156098
3.927 0.087266 0.0015 0.25 775.36 754.07 764.72
195000
5.893
0 0.0015
15.46749 30.93498
0.65
0 0.0015
0.25 0.25
754.07 781.20
747.43 781.20
750.75 781.20
195000 195000
747.43 781.20
749.76 781.20
195000 195000
1.0665
0 0.0015 0.25 781.20 779.95 780.58
195000
0.733 0.024435 0.0015 0.25 779.95 774.34 777.15
195000
12.901
0 0.0015 0.25 774.34 759.45 766.90
1.0165
0 0.0015 0.25 781.20 780.01 780.60
195000
0.733 0.024435 0.0015 0.25 780.01 774.40 777.20
195000
13.001
0 0.0015 0.25 774.40 759.40 766.90
195000
15.40054 30.80108
池州长江大桥及接线工程05标30米小箱梁预应力张拉计算书
由图纸设计可知预制小箱梁采用高强度、低松弛钢绞线,公称直径为15.20mm,截面面积Ay=140mm2, 其标准抗拉强度fpk=1860MPa,钢绞线弹性模量为Ey=1.95×105MPa,控制张拉应力为 0.75fpk=1395MPa,波纹管采用金属粘结波纹管,查表得到孔道偏差系数K=0.0015,管道摩擦系数μ =0.25
0.25 0.25
938.08 976.50
934.29 976.50
936.18 976.50
195000 195000
6.623
0 0.0015 0.25 976.50 966.83 971.67
195000
3.927 0.087266 0.0015 0.25 966.83 940.29 953.56
195000
15.3505 30.701
Ay(mm2) 560 560 560 560
560 560 560 560
560 560 560 560
560 560 560 560
ΔL(mm) 总伸长 4.650 70.779 27.295 6.062 108.786 217.5721 4.650 59.443 27.361 17.192 108.647 217.2939 4.650 48.084 27.428 28.349 108.511 217.0216 4.650 7.623 5.217 90.602
3.927 0.087266 0.0015 0.25 771.44 750.26 760.85
195000
2.5070 15.4455
0.65
0 0.0015 30.891
0 0.0015
0.25 0.25
750.26 781.20
747.45 781.20
748.86 781.20
195000 195000
6.7555
0 0.0015 0.25 781.20 773.31 777.26
195000
3.927 0.087266 0.0015 0.25 773.31 752.08 762.70
195000
4.129 15.4615
0.65
0 0.0015 30.923
0 0.0015
0.25 0.25
752.08 781.20
Ay(mm2) 700 700 700 700
700 700 700 700
560 560 560 560
560 560 560 560
ΔL(mm) 备注 4.650 58.217 27.369 18.470 108.706 217.4118 4.650 47.145 27.433 29.272 108.501 217.0014 4.650 35.618 27.500 40.514 108.282 216.5646 4.650 7.266 5.217 91.304
108.092 216.1844
序号
线段
L1
N1
L2
L3
L4 合计
L1
N2
L2
L3
L4
合计
L1
N3
L2
L3
L4 合计
L1
N4
L2
L3
L4
合计
30米边跨预应力箱梁张拉伸长量计算表
L(m) θ(rad) k
μ
0.65
0 0.0015 0.25
P1(N) 976.50
P2(N) 976.50
P(N) 976.50
195000
4.263 15.4630
0.65
0 0.0015 0.25 940.29 934.29 937.29 0 0.0015 0.25 781.20 781.20 781.20
195000 195000
4.9975
0 0.0015 0.25 781.20 775.36 778.28
195000
Ep(Mpa) 195000
8.188
0 0.0015 0.25 976.50 964.56 970.53
195000
3.927 0.087266 0.0015 0.25 964.56 938.08 951.32
195000
2.693
0 0.0015
15.45799 30.91598
0.65
0 0.0015
P1=0.75fpk*Ay
钢束编号 L1
N1 0.65 30米中跨箱梁 N2 0.65
N3 0.65 N4 0.65 N1 0.65 N2 0.65 30米边跨箱梁 N3 0.65 N4 0.65
Ay=n*140
P均=P(1-e-(kL+μθ))/(kx+μθ)
△L=P均*L/Ay*Ey
由图纸计算张拉端至计算截面的孔道长度
L(m) θ(rad) k
μ
0.65
0 0.0015 0.25
P1(N) 781.20
P2(N) 781.20
P(N) 781.20
Ep(Mpa) 195000
9.968
0 0.0015 0.25 781.20 769.58 775.39
195000
3.927 0.087266 0.0015 0.25 769.58 748.45 759.01
195000
0.885
0 0.0015
15.42999 30.85998
0.65
0 0.0015
0.25 0.25
748.45 781.20
747.46 781.20
747.95 781.20
195000 195000
8.3615
0 0.0015 0.25 781.20 771.44 776.32
195000
108.438 216.876
30米小箱梁负弯矩张拉伸长量计算表
序号 N1 N2 N3
线段 T1 T2 T3
L(m) 3.5 5 7.5
θ(rad) k 0 0.0015 0 0.0015 0 0.0015
μ 0.25 0.25 0.25
P1(N) 781.20 585.90 781.20
P2(N) 781.20 585.90 781.20