800 Dosino –开始参数标签: 方法▶设备▶ Dosino溶液Select the solution for the Dosino that should be available when the hardware is started with [Start HW]. A check is carried out in the method run to ensure that the correct solution has been put on the dosing device. When the method is started, the working life and GLP test interval are checked for the selected solution.选择未定义 | Solutions from the solution table默认值未定义未定义The solution is not checked.Solutions from the solution tableOnly "intelligent" solutions, i.e. solutions that are assigned to an 807 Dosing unit, can be selected.ConnectorShows the main device and the MSB connector which the 800 Dosino is on.800 Dosino –命令Overview of the time program commands available for the 800 Dosino: 加液对话窗口:方法▶时间程序▶编辑▶‘设备’–加液The device-dependent time program command Dosing (command with feedback) doses the specified volume via the defined port. There is no automatic filling beforehand or afterwards.参数PortPort via which dosing takes place. Formula input possible.1 (4)范围默认值 1V olumeVolume to be transported. Formula input possible.范围0.0000 ... 99999.9000 mL默认值 1.0000 mLDosing rateSpeed at which discharge takes place. The 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min默认值 1.00 mL/min选择最大值Filling rateSpeed at which filling takes place. The 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min默认值 1.00 mL/min选择最大值命令时间程序命令的可选注释。
Input64 characters生成的变量The following type 'mand number.Variable name' variables are generated by the command:吸液对话窗口:方法▶时间轴▶编辑▶‘设备’–吸液The device-dependent time program command Aspirate (command with feedback) draws in the specified volume via the defined port. As with the command Dosing, the cylinder is not filled automatically beforehand or afterwards. It should be possible to achieve the volume to be aspirated with a single piston stroke.参数PortPort via which aspiration takes place. Formula input possible.1 (4)范围默认值 1V olumeVolume to be transported. Formula input possible.范围0.0000 ... 50.0000 mL默认值 1.0000 mLRateThe 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min选择最大值默认值最大值命令时间程序命令的可选注释。
Input64 characters生成的变量The following type 'mand number.Variable name' variables are generated by the command:充液对话窗口:方法▶时间轴▶编辑▶‘设备’–充液The device-dependent time program command Fill (command with feedback) fills the cylinder via the specified port. The valve disc stops on the selected port.参数PortPort via which filling takes place. Formula input possible.范围 1 (4)默认值 2RateThe 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min选择最大值默认值最大值命令时间程序命令的可选注释。
Input64 characters排空对话窗口:方法▶时间轴▶编辑▶‘设备’–排空The device-dependent time program command Eject to end volume (command with feedback) ejects the entire contents of the cylinder via the specified port. In contrast to the command Eject to stop, the piston travels to the 最大值 volume mark i.e. until it has performed 10,000 pulses. This command should be used for pipetting functions for emptying the cylinder.参数PortPort via which ejection takes place. Formula input possible.范围 1 (4)默认值 4RateThe 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min选择最大值默认值最大值命令时间程序命令的可选注释。
Input64 characters排液到停止对话窗口:方法▶时间轴▶编辑▶‘设备’–排液到停止The device-dependent time program command Eject to stop (command with feedback) ejects the entire contents of the cylinder via the specified port. The piston is lowered to the stop point, i.e. past the 最大值 volume mark.注意:This function should only be carried out to eject any air bubbles present.CautionThe command aspirate does not function directly after Eject to stop.If aspiration is to take place after Eject to stop, then Eject to end volume must first be carried out. In this command, the port via which aspiration is to take place must already be selected.参数PortPort via which ejection takes place. Formula input possible.1 (4)范围默认值 4RateThe 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min选择最大值默认值最大值命令时间程序命令的可选注释。
Input64 characters交换位置对话窗口:方法▶时间轴▶编辑▶‘设备’ - 交换位置With the device-dependent time program command Exchange position (command with feedback) the cylinder is first filled via the port specified. The valve disc is then turned to Port 2 and the dosing unit can be removed from the dosing drive.参数Fill portPort via which filling takes place. Formula input possible.1 (4)范围默认值 2RateThe 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min选择最大值默认值最大值命令时间程序命令的可选注释。